Loc analog legacy millennia archival phono preamplifier (11 pages)
Summary of Contents for Millennia HV-316 Series
Page 1
Owner’s Manual HV-316 Remote-Controllable High Voltage Microphone Preamplifier Millennia Music & Media Systems...
Page 2
Link Assignment ........... 12 Scribble Strip..........12 Link Matrix ..........12 Scene Window ........... 13 Project and Scene Management ....13 Creating a Project ......... 13 Scene Window ..........13 Safety Prompts ..........13 Millennia Media HV-316 page 2 of 18...
Page 3
Water, Moisture, and Spillage – Do not attempt to use the HV-316 in, near, or around water or in unusually moist environments, such as near a sink or Congratulations on your purchase of the Millennia swimming pool. Prevent liquids or any other Media HV-316 Remote-Controllable High Voltage materials or objects from spilling or falling into the Microphone Preamplifier.
Page 5
Unit ID Display – Indicates unit number assigned to preamp. Rear Panel Functions 12 Volt Redundant (Auxiliary) Power – Connect only Millennia approved optional backup AC Power – IEC power inlet, 100-240V 50/60Hz. power supply here. MIDI Connection – Allows remote control of the Unit ID Selector –...
If you are using WiFi, turn it off and use the wired Ethernet connection to be sure all the permissions are applied to it so you connect the Millennia Preamp directly to your computer to initialize its IP address. Extract the zipped files and Open Select the location to save the file and click Next The following screen will appear.
Page 7
Run the Ælogic Software. Press the Windows key and the key at the same time to open the Run box. Type ncpa.cpl and hit Enter to access Network Connections immediately. 8age 7 of 18 rev 1.00 091220 Millennia Media HV-316...
Page 8
HV-316 network. The table below is a suggested addressing scheme. IP Address Unit ID 192.168.1.200 Host Computer 192.168.1.221 HV-316 ID 01 192.168.1.222 HV-316 ID 02 192.168.1.223 HV-316 ID 03 192.168.1.2nn HV-316 ID nn Millennia Media HV-316 page 8 of 18...
HV-3R only. If the unit is in Local mode when Ælogic is started, it won’t appear. Be sure to change the unit to Remote mode so the software can recognize Millennia’s Ælogic remote control software is the HV-3R. straightforward to operate. Here is an in-depth description of the available functions of the GUI.
Remote Mode. 11. Safe 12. Ribbon 13. High Pass Filter 14. Link Assignment 15. Scribble Strip Unit Naming and Unit Name Dialog Box (right-click on unit name) – Each Unit’s name is Millennia Media HV-316 page 10 of 18...
MUTE – Mutes channel output. When channel is muted, the meter will continue to operate allowing the user to view audio activity on that channel without passing live audio. Mute parameter is linkable. Button illuminates red. 8age 11 of 18 rev 1.00 091220 Millennia Media HV-316...
• Right click a link to bring up the channel naming shortcut ctrl-L or from the pull down menus dialog box. (Edit>Link). Millennia Media HV-316 page 12 of 18...
Scene Window. Left-clicking a Scene Number/Name of the units on the network. will highlight it. No system functions will change until the Recall button is clicked or until the desired scene is double-clicked. 8age 13 of 18 rev 1.00 091220 Millennia Media HV-316...
Page 14
Loss of Power – If the HV-316 loses power or ÆLogic crashes it will come back online with the parameters set the same as when it went off except parameters Link, Safe and Split will be off. Millennia Media HV-316 page 14 of 18...
Shift Ctrl S Save as Up/Down keys (on controls) Increment/Decrement gain by 1dB Microphone input wiring diagram – DB-25 to XLR Female AES59/Tascam Format Channel + Pins – Pins Pins 8age 15 of 18 rev 1.00 091220 Millennia Media HV-316...
Trying to set up IDs and IP address while Ælogic is running. Configure hardware before running the software. Close Ælogic and restart it. DHCP doesn’t work. You need to use a fixed IP address or install a DHCP server on your network. Millennia Media HV-316 page 16 of 18...
Page 17
FCC CFR 47 Part 15 Subpart B, Class A ICES-03 Issue 6 (Canada) ANSI C63.4-2014 Compliance CE (EN55022 / EN55024) RoHS 2002/95/EC WEEE 2012/19/EU REACH Environmental to +65 C / +15 to +150 10% to 80% RH 8age 17 of 18 rev 1.00 091220 Millennia Media HV-316...
International warranty law may vary from country faulty installation, improper adjustment, alteration or to country, and Millennia will abide by the law of each modification of product, incompatibilities, line-power surges, country. acts of God, or service performed by anyone other than Millennia Media or its authorized agent.
Need help?
Do you have a question about the HV-316 Series and is the answer not in the manual?
Questions and answers