4. INSTALLATION INSTRUCTIONS

/!\
ATTENTION
1. Place the machine on a proper workbench, which must be stable and strong enough to
stand the machine safely. Keep a sufficient distance (10/15 cm) on the right side of the
machine for the pipes and the feeding cables, as well as in order to have access to the
shutter and the filter. If a built-in WAFIS system is present, preferably choose a
workbench and a position (for instance on the bench edge) allowing the exhaust pipe to
fall perpendicularly into the collection tank.
2. Insert the quick clutch fitting on the male intake (A) located on the right side of the unit
and connect the pneumatic feeding pipe (polyethylene or rilsan, with diameter ∅ 8x6)
to the pipe-fitting. It is also possible to use a ∅ 12x6 elastic feeding pipe, by using the
fitting supplied with the unit.
3. Connect the electric feeding cable to the pre-fitted electric socket on the unit (B) and
plug into an approved 220v AC - 50Hz network socket with ground connection.
4. Install the preferred suction system; WAFIS, PRO-3 or any other.
The built-in WAFIS should be installed on the top left side of the
unit: unscrew the 4 screws fixing the black collection intake and
mount the WAFIS, unscrew the cap (C) and replace it by the pipe-
fitting delivered in the package, put together with the other portion
of pipe and plug the feeding cable into the electric socket (D).
5. Adjust the air flow to avoid the machine being under pressure. Slightly turn the mobile
section of the adjusting valve when the suction system is on and stop when you notice
that the gloves are still slightly inflated.
6. Lift the window and fill the hopper with the appropriate abrasive (observe the
indications below as for dimensions of nozzles and correct working pressure).
Installation of this machine is quite easy but must be carried out paying
utmost attention in order to avoid any mistake which may originate
problems, inconveniences and even damages during operation.
PRO-3 suction units should be
connected
collection pipe into the pre-fitted
intake.
Any other suction system can
be connected to the black
collection intake by means of flexible piping; the
inside manifold fits a ∅ 30mm pipe, the outside
manifold fits a ∅ 40mm pipe.