Do you have a question about the ACT III RD and is the answer not in the manual?
Questions and answers
Summary of Contents for Reflex ACT III RD
Page 1
Quick user Guide AcT iii rd Rapid Descent Core Orientation Tool reflexnow.com...
Page 2
Changes, typos, and technical inaccuracies will be corrected in subsequent publications. This publication is subject to change without notice. Determination of the suitability of any information or product for use contemplated by any user, and the manner of that use is the sole responsibility of the user. REFLEX™ Australia 216 Balcatta Rd, Balcatta WA 6021...
Breaking – Using the Depth Display Function ..................6 Initialise Second ACT III RD Tool ......................6 Retrieving Orientation from ACT III RD Using Dip and Depth Display Function ......6 Transferring Orientation to the Core .....................7 Section 3: Digital Audit Software Installation for Data Download Function ....8 Installing the ACT II Digital Auditor ......................8...
Inner Tube Fig. 3 N.B. There is no need to remove the backend spindle/grease cap from the backend. Tighten the inner tube, AcT iii rd and backend, as per standard drilling practice, using inner tube wrenches NOT pipe wrenches. Initialise ACT III RD 3.2.
N.B. if using the optional download function please refer to section 2, on page 6, of this manual for further instructions on how to enter the hole depth. Before the core can be broken off bottom at the end of the coring run, the bottom of hole orientation MusT be recorded on the AcT iii rd controller as follows: 4.6.
Retrieving Orientation from ACT III RD With the core inner tube assembly returned to the surface the bottom of hole orientation can now be retrieved from the AcT iii rd tool and transferred to the core using the same controller.
Cancelling a Tool in the event an AcT iii rd unit cannot be retrieved from the drilling barrel that particular tool must be cancelled from the AcT iii rd controller before a third replacement tool can be introduced as follows.
Breaking – Using the Depth Display Function N.B. steps 1–3 below should be followed if using an AcT iii rd tool that has the depth and dip display function enabled. Before the core can be broken off bottom at the end of the coring run, the bottom of hole orientation MusT be recorded on the AcT iii rd controller as follows: 1.1.
(Fig. 28). 3.6. With the AcT iii rd controller still connected to the infra red Port the inner tube assembly should be rotated in the direction of the arrows and red Leds are indicating (Fig. 29). As the bottom of hole orientation position approaches the Lcd arrows will reduce from 3 each side (Fig.
ACT III RD rapid descent core orientation tool Section 3: Digital Audit Software Installation for Data Download Function Installing The ACT II Digital Auditor save the AcT ii software to your computer. N.B. The AcT ii software is only Windows compatible Once saved double click ‘AcTiidA seTuP.msi’.
Page 11
Quick user Guide The AcT ii digital Audit software will install in the Program Files folder on your computer – if this install location is correct click NEXT, otherwise select BROWSE to navigate to the desired installation folder. N.B. The installation location must be on the main drive of the computer. The below pop-up window will appear –...
Page 12
– click CLOSE. N.B. ensure that .Net Framework has been updated on your Windows system. AcT ii digital Auditor icon The reflex AcT ii digital Auditor icon should now appear on your desktop.
Quick user Guide Downloading and Printing Orientation Data connect the AcT iii rd dock to your computer. controller Open the refl ex digital Auditor by double clicking the desktop icon. Open the refl ex digital Auditor by double clicking the desktop icon.
Page 14
AcT iii rd rapid descent core orientation tool insert the AcT iii rd controller. Press B and SET on the controller panel at the same time. N.B. ensure both buttons are pressed at the same time. The below pop-up window will appear – click DOWNLOAD RECORDS.
Page 15
Quick user Guide if saving the AcT iii data you will have the option to save in Microsoft excel (.xls) or Text (.txt) format. 6.1. After clicking SAVE, the below pop-up navigation window will appear. From the Save as type drop-down box select the file format you want to save the data in (i.e.
AcT iii rd rapid descent core orientation tool Section 4: Orientation Transfer Device Orientation Transfer Device Instructions in situations that do not permit two joined core inner tubes being removed in the one attempt, it may be necessary to separate them while inside the drilling mast.
Page 17
Tighten wing nut on device body to core inner tube Fig. 3 retrieve orientation information from AcT iii rd as per normal procedure. Once bottom of hole orientation is achieved keep the core inner tube still while rotating the levelling wheel of the transfer device until the (Fig.