Danfoss FP720 User Manual page 4

Two channel heating timer
Hide thumbs Also See for FP720:

Advertisement

User Guide
5
Select Away Mode
• Press CH for 3 seconds to enter Away mode and
• Press CH again to exit Away mode.
6
Set Control Parameters
Press
button for 6 seconds to enter the parameter setting mode. Press
set the parameter range via < or >. Complete all adjustments.
To exit parameter setup press
No.
Parameter settings
P1
Working mode
P2
Schedule periods
P3
Channel setup
P4
Timer display
P5
Auto daylight saving
P6
Holiday mode setup
P7
Service due setup
P8
Reset
Danfoss Heating
FP720 Two Channel Heating Timer
will be displayed.
, automatic exit after 20 seconds in no button is pressed.
01: Schedule timer 7 day
02: Schedule timer 5/2 day
03: Schedule timer 24hr
01: 1 period (2 events)
02: 2 periods (4 events)
03: 3 periods (6 events)
01: Heating + Domestic hot water
02: Two heating zones
01: 24hr
02: 12hr
01: On
02: Off
01: All channels off
02: Heating off only
Installer setting only
00: Reset off
01: Select reset
VUSUH102 | BC306937065292EN-000101
Settings range
for parameter selection and
Default
02
02
01
01
01
01
00