Scilogex SCI-O330-Pro User Manual

Orbital and linear digital shaker

Advertisement

Quick Links

SCI-O330-Pro & SCI-L330-Pro Orbital and Linear Digital Shaker
SCI-O180- Pro & SCI-L180-Pro Orbital and Linear Digital Shaker
Cat No.12300140
SCI-L330-Pro
SCI-O330-Pro
SCI-L180-Pro
SCI-O180-Pro
Please read the User Manual and the related Video of this
instrument on our website carefully before use, and follow
all operating and safety instructions!
The website www.scilogex.com
User Manual
Linear Digital shaker(7.5Kg)
Orbital Digital shaker(7.5Kg)
Linear Digital shaker(2.5Kg)
Orbital Digital shaker(2.5Kg)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SCI-O330-Pro and is the answer not in the manual?

Questions and answers

Summary of Contents for Scilogex SCI-O330-Pro

  • Page 1 SCI-O330-Pro & SCI-L330-Pro Orbital and Linear Digital Shaker SCI-O180- Pro & SCI-L180-Pro Orbital and Linear Digital Shaker User Manual SCI-L330-Pro Linear Digital shaker(7.5Kg) SCI-O330-Pro Orbital Digital shaker(7.5Kg) SCI-L180-Pro Linear Digital shaker(2.5Kg) SCI-O180-Pro Orbital Digital shaker(2.5Kg) Please read the User Manual and the related Video of this...
  • Page 2: Table Of Contents

    9.Interface Contents 10.Maintenance and Cleaning 11.Associated Standards and Regulations Contents Inside front cover 12.Technical Data Preface 13.Products and Accessories Service Warranty 1.Safety Instructions 2.Proper Use 3.Inspection 3.1 Receiving Inspection 3.2 Listing of Items 4. Trial Run 5.Control and Set 5.1 Control 5.2 Set 5.2.1 Set Time 5.2.2 Setting Speed...
  • Page 3: Preface

    You have purchased a Scilogex instrument. This instrument is warranted to be free from defects in materials and workmanship under normal use and service, for a period Service of 24 months from the date of invoice.
  • Page 4: Safety Instructions

    splashing out of liquid when setting the motor speed. Reduce 1.Safety Instructions the motor speed if the instrument is not running smoothly. Warning! • Accessories must be securely attached to the instrument • Read the operating instructions completely so that it cannot come off by itselves, and vessels must be before use and follow the safety instructions.
  • Page 5: Proper Use

    SK-O(L)330- Pro Orbital and Linear Digital Shaker SK-O(L)180- Pro Orbital and Linear Digital Shaker 2.Proper use Items The instrument is designed for mixing or shaking liquids in Main unit schools, laboratories or factories. SK-330/180-Pro is suitable Power cable for usage in various attachments for mixing liquids in User manual bottles, flasks, test tubes for a maximum supported weight of Table 1...
  • Page 6: Control And Set

    SK-O(L)330- Pro Orbital and Linear Digital Shaker SK-O(L)180- Pro Orbital and Linear Digital Shaker If the mounting surface is not even, you can improve the 5.Control and Set stability of the instrument with the adjustable feet. To do 5.1 Control this, turn the appropriate foot downward with the wrench Shaking table until the instrument is standing securely on the surface.
  • Page 7: Set

    SK-O(L)330- Pro Orbital and Linear Digital Shaker SK-O(L)180- Pro Orbital and Linear Digital Shaker • Put the instrument on stable and safe place and plug in the set time. After the instrument is powered OFF and restarted, mains power. the set time is erased to zero blanking and it switches into •...
  • Page 8: Operating Modes

    Note: The current set speed can be varied at any time. Figure 4 • The set or stored speed value is shown in the left display, and 6.Operating modes the set or stored time value is shown in the right display. Turn the speed knob and time knob can set the speed and time.
  • Page 9: Mode B

    6.2 Mode B When the instrument is turned ON and values for speed and time are erased to zero, users can set. The upper speed Figure 9 limit that has been set is taken over from operating mode A and cannot be modified. After the power has been turned OFF, the instrument will no longer automatically start up in operating Mode B by itself.
  • Page 10: Switch The Shaking Direction

    the mains switch. After about 5 second, you can let go of the Check whether the power cable fitted well ■ knobs. Check whether the fuse is broken ■ • Switch between operating Modes A and B in order. • The speed cannot reach set value Check whether it is overloaded ■...
  • Page 11: Maintenance And Cleaning

    Note: 10.Maintenance and cleaning • Electrical instrument may not be placed in the Use and maintain the instrument in right way to keep it in cleansing agent for the purpose of cleaning. good operating state in order to lengthen its life time and •...
  • Page 12: Technical Data

    12.Technical data Timer display Time setting range [min] 1 – 1199 Items Parameters Voltage [VAC] 100~240 Items Parameters Run type Time / Continuous operation Frequency [Hz] 50/60 420×370×100(SK-O(L)330- Power [W] Dimensions [D×W×H P r o ) / 3 4 0 × 3 0 0 × 1 0 0 ( S K - Shaking movement Orbital/ linear O(L)180-Pro)
  • Page 13 18900041 SK330.4 Dish Attachment (with SK330.4 slip-resistant foil) 18900028 SK 330.2 Fixing Clip Attachment SK 330.2 Bars for SK330.1 Universal 18900036 Attachment, black Accessories Accessories Cat.No and 18900025 SK 180.1 Operation mode Figure Designation Universal SK 180.1 Attachment 18900027 SK 330.1 Universal 18900038 SK330.1...
  • Page 14 18900031 F i x i n g C l i p s f o r SCILOGEX, LLC Flask Volume 100 SK330.2.3 1275 Cromwell Ave. Suite C6 Rocky Hill, CT 06067 USA Tel: +1(860) 436-9221 Fax: +1(860) 436-9745 info@scilogex.com | www.scilogex.com...