  • Page 1 FLC 3701 - MPI Extension Card INSTALLATION GUIDE IG-0029-00 1.2 en-US ENGLISH...
  • Page 2 Important User Information Disclaimer The information in this document is for informational purposes only. Please inform HMS Industrial Networks of any inaccuracies or omissions found in this document. HMS Industrial Networks disclaims any responsibility or liability for any errors that may appear in this document. HMS Industrial Networks reserves the right to modify its products in line with its policy of continuous product development.
  • Page 3: Table Of Contents

    Table of Contents Page Preface ..........................3 About This Document .......................3 Document history ......................3 Related Documents ......................3 Trademark Information .....................3 Product Summary........................ 4 Safety, Environmental & Regulatory Information ............. 5 Scope..........................5 ESD Damage Prevention ....................5 Applicable Directives, Standards and Compliances ..............5 Hardware Description ......................
  • Page 4 This page intentionally left blank...
  • Page 5: Preface

    Preface 3 (16) Preface About This Document This document describes the hardware of the FLC 3701 - MPI extension card which is operational with the Ewon Flexy 205 only. The Ewon Flexy family is a range of modular industrial gateway/router and as its name Ewon Flexy suggests, it has been designed to enable numerous different combinations of base units with extension cards.
  • Page 6: Product Summary

    Product Summary 4 (16) Product Summary The present Installation Guide is focusing on the FLC 3701 - MPI extension card which is not a standalone product and must be inserted in a Flexy 205 base unit to work. The Flexy 205 has its own Installation Guide which can be found in the Related Documents, p.
  • Page 7: Safety, Environmental & Regulatory Information

    Safety, Environmental & Regulatory Information 5 (16) Safety, Environmental & Regulatory Information Scope The present heading addresses Safety, Environmental & Regulatory Information about the FLC 3701 - MPI extension card. This extension card belongs to the same compliance frame than the Flexy 205. In the present case of a telecommunication extension card, additional directives, standards and instructions apply.
  • Page 8 Safety, Environmental & Regulatory Information 6 (16) • This product may not cause harmful interference • This product must accept any interference received, including interference that may cause undesired operation. 3.3.4 Certifications The FLC 3701 has been certified by authorized bodies: •...
  • Page 9: Hardware Description

    Hardware Description 7 (16) Hardware Description Mechanical Layout and Interfaces Fig. 1 Mechanical Layout and Interfaces Female SUBD9 MPI port. Backplane connector Extension Card Label 4.2.1 Label Location and Included Information The identification label of the extension cards is placed on the solder side of the PCB. The different parts of the label are described below: Description Label...
  • Page 10: Front Panel Leds

    Hardware Description 8 (16) 4.2.2 Part Number Structure for Extension Cards FLYXXXX_00/S FL is the prefix for the extensions of the Ewon Flexy family Only FL (constant) ●●○○ 1 alphabetic sign (CAP) 2 first slots only Defines the slots of the base module in which the extension card can be inserted.
  • Page 11: Mpi Port Specification

    Hardware Description 9 (16) MPI Port Specification Characteristic Value Physical mode MPI (1500V galvanic isolation through the power supply isolation from ground). Baud rates From 9.6 kBauds to 12.0 MBauds. Polarization 100 kΩ Termination None Pin # SUBD9 female connector pinout –...
  • Page 12: Plugging The Extension Card Into The Base Unit

    Plugging the Extension Card into the Base Unit 10 (16) Plugging the Extension Card into the Base Unit Base Unit Slot Compatibility The FLC 3701 must be inserted in one of the “Type C” slots of the base unit. The reference code of the extension cards includes a letter defining their compatibility: •...
  • Page 13: Extension Card Insertion

    Plugging the Extension Card into the Base Unit 11 (16) Extension Card Insertion 5.2.1 How to Insert into the Flexy Base Unit Wait 30 seconds after turning off the equipment before inserting (or removing) an extension card to avoid possible damage to the base unit and the extension cards. Remove the slot filler of the location the new card will be inserted.
  • Page 14 Plugging the Extension Card into the Base Unit 12 (16) 5.2.2 Insertion of Multiple FLC 3701 Detection Order The boot sequence of the base unit includes an automated detection of the inserted extension cards. This detection is done sequentially, slot per slot starting from left to right (when holding the base unit with its logo on the right side).
  • Page 15: Powering On The Base Unit With Its Extension Cards

    Powering on the Base Unit with its Extension Cards 13 (16) Powering on the Base Unit with its Extension Cards When the base unit is powered on, it takes approximately 25 seconds for the unit to go through its self-test procedure. The slots in which the extension cards have been inserted and their type are detected during this process.
  • Page 16: Check Card Detection On The Embedded Web Page

    Check Card Detection on the Embedded Web Page 14 (16) Check Card Detection on the Embedded Web Page The Flexy extension cards require no software configuration. They are automatically detected by the base unit when the device boots. Connecting to the Embedded Web Server Configure the network parameters to set the computer being used to reach the web interface on the same IP range than the LAN of the Ewon device.