  • Page 1 ES4100.1 Chassis VME64x User’s Guide...
  • Page 2 The data in this document may not be altered or amended without special noti- fication from ETAS GmbH. ETAS GmbH undertakes no further obligation in rela- tion to this document. The software described in it can only be used if the customer is in possession of a general license agreement or single license.
  • Page 3: Table Of Contents

    Installation of VMEbus Boards ........17 ES4100.1 Chassis VME64x - User’s Guide...
  • Page 4 6 ETAS Contact Addresses ........
  • Page 5: Introduction

    Please read the documentation accompanying the product carefully before using the product. ETAS GmbH cannot be made liable for damage which is caused by incorrect use and handling and not adhering to the safety instructions. ES4100.1 Chassis VME64x - User’s Guide...
  • Page 6: Connecting/Removing Devices

    Please take the following precautionary measures to avoid any injuries and dam- age to hardware: • Do not apply any voltages to the ports of the ES4100.1 Chassis VME64x which do not correspond to the specifications of the relevant port. Refer to the corresponding boards’...
  • Page 7 – The simulation of the vehicle battery itself is not a component part of the ES4100.1 Chassis VME64x and cannot be integrated here. The ES4100.1 Chassis VME64x must always be integrated in an ETAS casing spe- cially designed for this purpose (i.e. ES4015.2 Housing 9U) or in a 19" rack sys- tem and must not be used as a "standalone"...
  • Page 8: Identifications On The Product

    1.4.1 European Union The EU Directive 2002/95/EU limits the use of certain dangerous materials for electrical and electronic devices (RoHS conformity). ETAS confirms that the product corresponds to this directive which is applicable in the European Union. 1.4.2 China ETAS confirms that the product meets the product-specific applicable guidelines...
  • Page 9: Taking The Product Back And Recycling

    The user is obliged to collect the old devices separately and return them to the WEEE take-back system for recycling. The WEEE Directive concerns all ETAS devices but not external cables or batteries. For more information on the ETAS GmbH Recycling Program, contact the ETAS sales and service locations (see "ETAS Contact Addresses"...
  • Page 10: About This Manual

    This chapter • "Functional Description" on page 13 This section contains detailed information about the features and applica- tions of the ES4100.1 Chassis VME64x. • "Operation" on page 17 This section provides information about the installation and removal of the VMEbus boards, fuse replacement.
  • Page 11 A conversion between the file types Content markings and newly introduced logical and arithmetic is not possi- terms are shown in italics ble. Important notes for the user are shown as follows: Note Important note for the user. ES4100.1 Chassis VME64x - User’s Guide...
  • Page 12 Introduction ETAS ES4100.1 Chassis VME64x - User’s Guide...
  • Page 13: Functional Description

    ES4100.1 Chassis VME64x. Features The ES4100.1 Chassis VME64x is designed to hold the VME boards. It is respon- sible for the mechanical mounting of the boards, the connection of the boards with the VMEbus, the power supply, and the cooling of the boards.
  • Page 14: Applications

    Mechanical Structure The ES4100.1 Chassis VME64x is designed with 19" geometry and 4 U front panel height. The power switch and displays are located on the front panel. The figure below shows a cut-out section of the chassis.
  • Page 15: Slots

    You can find the information on the current consumption of a board in the corresponding User’s Guide for the board. In case of nonobservance the ES4100.1 and built in boards may be damaged and there is the danger of fire through overheating.
  • Page 16 Functional Description ETAS ES4100.1 Chassis VME64x - User’s Guide...
  • Page 17: Operation

    • Disconnect all connectors from the board you want to remove. • Loosen the mounting screws at the top and bottom edge of the board’s front panel. • Grasp the handle of the board and pull the board carefully out. ES4100.1 Chassis VME64x - User’s Guide...
  • Page 18: Fuses

    (Tab. 3-1). In case of a fuse defect, we recommend sending the ES4100.1 Chassis VME64x to ETAS for further testing. For this purpose, the device should be sent to ETAS (see "ETAS Contact Addresses" on page 27).
  • Page 19 Specification of the Fuses F100 - F103 and Order Numbers To replace the fuses F100 - F103 The fuses are located inside the ES4100.1 housing next to the power supply unit. • Turn off the power to the ES4100.1. Check that all devices connected to the ES4100.1 by cables have...
  • Page 20 Operation ETAS ES4100.1 Chassis VME64x - User’s Guide...
  • Page 21: Connections And Connectors

    +3.3 V RsvBus /IACKIN SERA RsvBus /IACKOUT SERB +3.3 V RsvBus RsvBus /IRQ7 +3.3 V RsvBus /IRQ6 RsvBus /IRQ5 +3.3 V RsvBus /IRQ4 LI-/I /IRQ3 +3.3 V RsvBus /IRQ2 LI-/O Tab. 4-1 Pin Allocation VME64x ES4100.1 Chassis VME64x - User’s Guide...
  • Page 22: Power Cables

    Pin Allocation VME64x (Forts.) Power Cables Due to regional differences in the power supply, ETAS does not supply power cord cables with the ES4100.1 Chassis VME64x. The following table contains details of the relevant requirements and the ETAS order numbers.
  • Page 23: Technical Data

    • China RoHS • WEEE Symbol • CE marking • A warning symbol that indicates that the User’s Guide must be read before operating and opening the ES4100.1 Chassis VME64x! General Data Mechanical structure 19" chassis for cabinet mounting Slots...
  • Page 24 2x T6.3 A/250 V (6.3x32 mm) Backplane Standard VME64x Number of pins 160 per slot Compatibility Standard VMEbus, VME64x Ventilation Fan Control Temperature sensor in the vicinity of the boards Fault indication Front panel LED ES4100.1 Chassis VME64x - User’s Guide...
  • Page 25: Fulfilled Standards And Norms

    This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. Ordering Data The ordering data of the ES4100.1 Chassis VME64x is as follows: Ordering Name Short Name Order Number ES4100.1 Chassis VME64x...
  • Page 26 Technical Data ETAS ES4100.1 Chassis VME64x - User’s Guide...
  • Page 27: Etas Contact Addresses

    Germany WWW: www.etas.com ETAS Subsidiaries and Technical Support For details of your local sales office as well as your local technical support team and product hotlines, take a look at the ETAS website: ETAS subsidiaries WWW: www.etas.com/en/contact.php ETAS technical support WWW: www.etas.com/en/hotlines.php...
  • Page 28 ETAS Contact Addresses ETAS ES4100.1 Chassis VME64x - User’s Guide...
  • Page 29: Index

    Documentation 5 RoHS conformity China 8 European Union 8 Electrical safety 7 ETAS Contact Addresses 27 Safety instructions 5 Safety instructions, labeling 5 Features 13 Standards and norms 25 Front panel 13 Supply voltage 24 ES4100.1 Chassis VME64x - User’s Guide...
  • Page 30 Index ETAS Technical data 23 Use, correct 6 Ventilation fan 24 Waste Electrical and Electronic Equip- ment 9 WEEE take-back system 9 ES4100.1 Chassis VME64x - User’s Guide...