Download Print this page

Air Sponge Airsponge Installation Instructions page 2

Dehumidistat

Advertisement

WIRING
Personal Injury Hazard.
Power supply can cause electrical shock. Disconnect power supply before beginning installation.
All wiring must comply the applicable local codes, ordinances and regulations. Make wiring connections according to
dehumidifier instructions; otherwise see typical wiring diagram in Figure 2.
ADJUSTMENTS
Humidity Control Adjustment
To maintain optimum humidity control without causing condensation on cold surfaces such as windows, the
homeowner must adjust the set point as the outdoor temperate changes.
To reduce the relative humidity, reduce the set point approximately three percent relative humidity every 24 hours.
To increase the relative humidity increase the set point approximately three percent relative humidity ever 24 hours.
Set Point Adjustment
Set the humidity set point according to the prevailing outdoor temperature. See table below for recommended
settings.
OPERATION AND CHECKOUT
Place the system in operation and observe through at least one complete cycle to make certain that all components
are functioning properly.
Recommended Humidity Controller Settings
Outdoor Temperature
F
-20
-10
0
+10
+20
>+20
Figure 2 - Diagram for
Recommended Humidity
Controller Setting
C
-29
-23
-18
-12
-7
>-7
Dehumidifier
15
20
25
30
35
40

Advertisement