Arcam Solo Movie 2.1 Custom Installation Notes

Arcam Solo Movie 2.1 Custom Installation Notes

Hide thumbs Also See for Solo Movie 2.1:

Advertisement

Quick Links

Custom Installation Notes:
Serial programming interface and
IR remote commands for
Arcam Solo Movie 2.1 and 5.1
MENU
SOURCE
INFO
OK
����
TAPE
MENU
SOURCE
INFO
OK
����
TAPE
Models covered:
Solo Movie 2.1
Solo Movie 5.1
�����������
���
�����������
���
VOLUME
POWER
VOLUME
POWER

Advertisement

Table of Contents
loading

Summary of Contents for Arcam Solo Movie 2.1

  • Page 1 Custom Installation Notes: Serial programming interface and IR remote commands for Arcam Solo Movie 2.1 and 5.1 ����������� ��� MENU SOURCE INFO VOLUME ���� POWER TAPE ����������� ��� MENU SOURCE INFO VOLUME ���� POWER TAPE Models covered: Solo Movie 2.1...
  • Page 2: Table Of Contents

    Solo Movie 2.1 2.7 onwards Solo Movie 5.1 2.7 onwards The latest version of this document is available on the Arcam Dealer extranet accessed via www.arcam.co.uk/extranet If you cannot yet access the Dealer extranet, please apply by email to nadinec@arcam.co.uk RS232 Arcam (A&R Cambridge Ltd), Pembroke Avenue, Waterbeach, CAMBRIDGE, CB25 9QR, England...
  • Page 3: Controlling The Arcam Solo Movie Via Rs232

    Introduction Solo Movie is fitted with an RS232 serial connector that allows remote control from a PC, or similar device. This section of the document describes the protocol for controlling Solo Movie 2.1 or 5.1 via the RS232 interface. Conventions <...
  • Page 4: Example Command And Response Sequence

    Zone Data 0x21 0x01 0x0A 0x02 0x01 0x04 0x0D Note: RS232 control is disabled if the iPod option is enabled. RS232 Arcam (A&R Cambridge Ltd), Pembroke Avenue, Waterbeach, CAMBRIDGE, CB25 9QR, England (solo movie) +44 (0)1223 203200 www.arcam.co.uk/extranet...
  • Page 5: Rs232 Commands

    … 0x21 0x01 0x05 0x01 0x65 0x0D Command: 0x6B = +7 0x21 0x01 0x05 0x01 0x01 0x65 0x0D 0xF0 = Query Response: RS232 Arcam (A&R Cambridge Ltd), Pembroke Avenue, Waterbeach, CAMBRIDGE, CB25 9QR, England (solo movie) +44 (0)1223 203200 www.arcam.co.uk/extranet...
  • Page 6: Treble

    1: 0xF0 = Query 0x21 0x01 0x0A 0x01 0x01 0x0D Command: 0x21 0x01 0x0A 0x01 0x01 0x01 0x0D Response: RS232 Arcam (A&R Cambridge Ltd), Pembroke Avenue, Waterbeach, CAMBRIDGE, CB25 9QR, England (solo movie) +44 (0)1223 203200 www.arcam.co.uk/extranet...
  • Page 7: Stand-By Display Brightness

    0x01 (Zone) 0x37 (Reply Code) 0x01 (Answer code) 0x01 (Number of bytes) DATA 0x00 = DAB/FM module fitted 0x01 = AM/FM module fitted RS232 Arcam (A&R Cambridge Ltd), Pembroke Avenue, Waterbeach, CAMBRIDGE, CB25 9QR, England (solo movie) +44 (0)1223 203200 www.arcam.co.uk/extranet...
  • Page 8: Radio Station

    Response to the DAB MPEG mode request: 0x00 Response to the DAB data rate request: 0x00 Response to the signal strength request: 0x00 RS232 Arcam (A&R Cambridge Ltd), Pembroke Avenue, Waterbeach, CAMBRIDGE, CB25 9QR, England (solo movie) +44 (0)1223 203200 www.arcam.co.uk/extranet...
  • Page 9: Radio Programme Type

    (See IR section/document for details) 0x21 0x01 0xE9 0x02 0x10 0x21 0x0D Command: 0x21 0x01 0xE9 0x02 0x02 0x10 0x21 0x0D Response: RS232 Arcam (A&R Cambridge Ltd), Pembroke Avenue, Waterbeach, CAMBRIDGE, CB25 9QR, England (solo movie) +44 (0)1223 203200 www.arcam.co.uk/extranet...
  • Page 10: Dvd Player Status

    0x21 0x01 0x50 0x01 0x02 0x01 0x05 0x0D Response: 0x01 (Zone) 0x50 (Reply Code) 0x01 (Answer code) 0x02 (Number of bytes) MSB = Current Angle LSB = Total Angles RS232 Arcam (A&R Cambridge Ltd), Pembroke Avenue, Waterbeach, CAMBRIDGE, CB25 9QR, England (solo movie) +44 (0)1223 203200 www.arcam.co.uk/extranet...
  • Page 11: Dvd Subtitle

    0x01 (Zone) 0x55 (Reply Code) 0x01 (Answer code) 0x03 (Number of bytes) DATA MSB = Hours Byte = Minutes LSB = Seconds RS232 Arcam (A&R Cambridge Ltd), Pembroke Avenue, Waterbeach, CAMBRIDGE, CB25 9QR, England (solo movie) +44 (0)1223 203200 www.arcam.co.uk/extranet...
  • Page 12: Dvd Total Disc-Group-Title-Time Information

    0x06 (Number of bytes) DATA MSB = Current Group/Title (0~99) BYTE = Total Group/Title(0~99) BYTE(2) = Current Chapter/Track (0~999) LSB(2) = Total Chapters/Tracks (0~999) RS232 Arcam (A&R Cambridge Ltd), Pembroke Avenue, Waterbeach, CAMBRIDGE, CB25 9QR, England (solo movie) +44 (0)1223 203200 www.arcam.co.uk/extranet...
  • Page 13: Playback Time

    0x21 0x01 0x47 0x01 0x03 0x0D Command: 0x04 = 1080i 0x21 0x01 0x47 0x02 0x01 0x03 0x0D Response: 0x06 = 768p 0x80 = Auto 0xF0 = Query RS232 Arcam (A&R Cambridge Ltd), Pembroke Avenue, Waterbeach, CAMBRIDGE, CB25 9QR, England (solo movie) +44 (0)1223 203200 www.arcam.co.uk/extranet...
  • Page 14: Audio Stream Decode Mode

    0x00 = 0 minutes … 0x3B = 59 minutes Seconds 0x00 = 0 seconds … 0x3B = 59 seconds DATA 0xF0 = Query RS232 Arcam (A&R Cambridge Ltd), Pembroke Avenue, Waterbeach, CAMBRIDGE, CB25 9QR, England (solo movie) +44 (0)1223 203200 www.arcam.co.uk/extranet...
  • Page 15: Ir Remote Commands

    IR remote commands The following tables give the IR (infrared) remote commands accepted by the Arcam Solo Movie. AMP commands TUN commands System code 16 System code 17 Decimal Code Command Decimal Code Command 16-0 Source SAT 17-0 Tuner Number 0...
  • Page 16: Aux Commands

    Standby On 25-30 DVD Slow Play Forward 25-31 DVD Slow Play Back 25-32 DVD Track Forward 25-33 DVD Track Back 25-37 Trims RS232 Arcam (A&R Cambridge Ltd), Pembroke Avenue, Waterbeach, CAMBRIDGE, CB25 9QR, England (solo movie) +44 (0)1223 203200 www.arcam.co.uk/extranet...
  • Page 17 SH194 Issue 3 A&R Cambridge Ltd, Pembroke Avenue, Waterbeach, CAMBRIDGE, CB25 9QR, England +44 (0)1223 203200 www.arcam.co.uk/extranet...

This manual is also suitable for:

Solo movie 5.1

Table of Contents