Transcell Technology TI-1500VC Setup And Operation Manual

Weighing transmitter

Advertisement

R
TI-1500VC
Weighing Transmitter
Setup / Operation Manual
Ver 3.5C
2018-05
Transcell Technology, Inc.
Add: 975 Deerfield Parkway Buffalo Grove, IL U.S.A.
Zip: 60089
Tel: 01-800-503-9180
01-847-419-9180
Fax: 01-847-419-1515
Web Site: www.transcell.net
Transcell Technology, Inc.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TI-1500VC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Transcell Technology TI-1500VC

  • Page 1 TI-1500VC Weighing Transmitter Setup / Operation Manual Ver 3.5C 2018-05 Transcell Technology, Inc. Add: 975 Deerfield Parkway Buffalo Grove, IL U.S.A. Zip: 60089 Tel: 01-800-503-9180 01-847-419-9180 Fax: 01-847-419-1515 Web Site: www.transcell.net Transcell Technology, Inc.
  • Page 2: Table Of Contents

    4.3.4 Adjust the Auto Zero Range (F15)……………………………13 4.3.5 Adjust DA (F25) ………………………………………………..13 5. RS485 Communication Port………………………………………15 5.1 Connecting the RS485 output……………………………….15 5.2 Communication Mode of RS485 ……………………………15 5.3 Data Format (TI-1500VC Vision: V3.5C) ………………….16 5.4 Command Format ……………………………………………17 Hardware Vision Explain……………………………………………..18...
  • Page 3: Ti-1500Vc Specifications

    1. TI-1500VC Specifications 2. Dimensions & Installation 2.1 TI-1500VC Dimension: (1) Analog Signal Input: The transmitter can drive 4 x 350Ωload cell. The signals input every channel can be adjusted. The excitation voltage is +5V. (2) Interface: a. 4—20mA analog output (with digital adjust) b.
  • Page 4: Ti-1500Vc Setup Menu

    0.5d input/output are in one network, the last Band Note that the scale must be in TI-1500VC’s J4 should be in standstill to automatically zero. 8d 9d RS485 re-phase short circuit, RS-485 Selections are in Display...
  • Page 5 2 √ Selects the range within which Determines location of the 0√ Zero Range the scale may be zeroed. Note Decimal Pt. decimal point. 0.00 0.000 that the indicator must be in 0.0000 00 standstill to zero the scale. Allows the lb/kg key to be Cr-DIS√...
  • Page 6: User Menu

    3.2 User menu Changing communication mode and formula is in this menu. Allows you to key-in known zero Press ZERO Key-in Zero calibration value in case of key to begin A menu memory loss in the field. sequence Name/Code Description Code/Value Allows you to key-in a known Press ZERO...
  • Page 7: Operation

    2. In F or A menu mode, press and hold “↑” key, back to normal weigh mode. 4.2 Display and Annunciator Definitions of keys function TI-1500VC is utilized a blue 7-segments LCD display. Follow is the display detail: Keyboard Setting Mode...
  • Page 8: Ti-1500Vc Calibration

    A/D count. When the stabile annunciator turns on, press “↓” key to set zero point, Note: Every TI-1500VC has Factory Reset (F21) when it out of then press “SET” key to save the zero value.
  • Page 9: Adjust The Manual Zero Range (F4)

    4.3.5 Adjust DA (F25) The analog output 4-20mA and 0-10V has been adjusted, when the TI-1500VC out of the factory. The parameter should not be adjusted again generally. If necessary, please follow the step: (1) Enter F23 to select the type of analog output.
  • Page 10: Rs485 Communication Port

    Weight State Parity Data Units TI-1500VC adr:00 5.3 Data Format ( TI-1500VC Vision:V3.5c) b. Point to Multi-point Start Transmission (1 bit): STX; TI-1500VC Device Address (2 bits): Address information; adr:01 I/O port state (3 bits): I/O port state information; Weight Data (8 bits): Symbol (1 bit) + Decimal Point (1 bit) + xxxxxx TI-1500VC (6 bits, integer type);...
  • Page 11: Command Format

    Show as follow figure. There is a hardware’s mark label paste near the power terminal. So the different PCB board which marks Operational command (2 bits): different sign can not be changed. Otherwise the TI-1500VC will be GD: Get weight data; destroyed. If the transmitter out of operate because of the GC: Get calibration information;...