5.
MAINTENANCE
WARNING! Before attempting any maintenance ensure the unit is unplugged from the mains power supply, that it is cool and it is on level ground.
p
DO NOT touch the lamp glass, even when cold.
7
DO NOT use the heater without the guards fitted.
7
5.1
Cleaning.
5.1.1.
To clean the reflector, remove the guard by unscrewing the retaining screws and wipe the reflector with a clean dry cloth. DO NOT use abrasives or
solvents. The surface of the reflector is very soft and scratches may cause it to overheat. Replace the guard.
5.2.
Changing a lamp (110V models).
WARNING! Lamps should only be changed by a qualified electrician.
p
5.2.1.
Remove the front grille by unscrewing the retaining screws.
5.2.2.
Remove the side reflectors by unscrewing the retaining screws.
5.2.3.
Ease the spring clips on the ends of the lamp and pull the lamp forward such that it clears the edge of the clips but is still retained in the clips.
5.2.4.
Remove the back panel of the unit by unscrewing the retaining screws.
Note:
The back panel of the IRC153 provides rigidity when fitted. Removal of the back panel renders the heater unstable.
5.2.5.
Disconnect the lamp supply leads from the switch inside the heater.
5.2.6.
Remove the lamp from the spring clips.
5.2.7.
Fitting the new lamp is the reverse of paragraphs 5.2.1. to 5.2.6. NEVER TOUCH THE LAMP GLASS DIRECTLY WITH FINGERS, ONLY TOUCH THE
CERAMIC EDGES OR USE A SOFT CLOTH, OTHERWISE THE LAMP COULD BE DAMAGED!
Changing a lamp (230V models).
5.2.8.
Remove the front grille by unscrewing the retaining screws.
5.2.9.
Remove the side reflectors by unscrewing the retaining screws.
5.2.10. Carefully extract the lamp from side fittings.
5.2.11.
Extract the new lamp form the shipping carton. NEVER TOUCH THE LAMP GLASS DIRECTLY WITH FINGERS, ONLY TOUCH THE CERAMIC EDGES
OR USE A SOFT CLOTH, OTHERWISE THE LAMP COULD BE DAMAGED!
5.2.12. Carefully insert the lamp into the two push-in side fittings with a gentle pressure.
5.2.13. Check the lamp is properly locked.
5.2.14. Reassemble side reflectors and front guard.
IRS153.V2 & IRS153.110V
Declaration of Conformity
INFRA-RED SPACE WARMERS
Models: IRC153.V2, IRC153.110V,
IRS153.V2 & IRS153.110V
73/23/EEC Low Voltage Directive
89/336/EEC EMC Directive
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
We, the sole importer into the UK, declare that the products listed here are in conformity with the following standards and directives.
The construction files for these products are held by the Manufacturer and may be inspected, by a national authority,
upon request to Jack Sealey Ltd.
Sole UK Distributor
Sealey Group,
Bury St. Edmunds, Suffolk.
IRC153.V2 & IRC153.110V
Signed by Mark Sweetman
For Jack Sealey Ltd. Sole importer into the UK of Sealey Power Products.
01284 757500
01284 703534
1st July 2004
www.sealey.co.uk
Web
sales@sealey.co.uk
email
IRC153.V2, IRC153.110V, IRS153.V2, IRS153.110V - 1 - 010704

Advertisement

loading

This manual is also suitable for:

Irc153.110vIrs153.v2Irs 153.110v