E683x Series Installation Guide
Dimensions
Installation
ZL0170-0A
Page 2 of 2
Alta Labs, Enercept, Enspector, Hawkeye, Trustat, Aerospond, Veris, and the Veris 'V' logo are trademarks or registered trademarks of Veris Industries, L.L.C. in the USA and/or other countries.
1.05 in. (26.50 mm)
2.84 in.
(72 mm)
3.76 in. (96 mm)
5.76 in. (146 mm)
7.52 in. (191 mm)
11.28 in. (287 mm)
(FOR REFERENCE ONLY)
DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
• Do not use this product for life or safety applications.
• Do not install this product in hazardous or classified locations.
• Mount this product inside a suitable fire and electrical enclosure.
• Apply appropriate personal protective equipment (PPE) and follow safe electrical
work practices. See NFPA 70E in the USA, CSA Z462 or applicable local standards.
• This equipment must only be installed and serviced by qualified electrical personnel.
• Read, understand and follow the instructions before installing this product.
• Turn off all power supplying equipment before working on or inside the equipment.
• Product may use multiple voltage/power sources. Disconnect all sources before
servicing.
• Use a properly rated voltage sensing device to confirm that power is off. Do not
depend on this product for voltage indication.
• Current transformer secondaries must be shorted or connected to a burden at all times.
• Replace all doors, covers and protective devices before powering the equipment.
Failure to follow these instructions will result in death or serious injury.
Electrical equipment should be installed, operated, serviced and maintained only by
quali ed personnel. No responsibility is assumed by Veris Industries for any
consequences arising out of the use of this material. A quali ed person is one who has
skills and knowledge related to the construction, installation and operation of
electrical equipment and has received safety training to recognize and avoid the
hazards involved.
Installation, wiring, testing and service must be performed in accordance with all local
and national electrical codes.
If this product is be used in a manner not speci ed by the manufacturer, the
protection provided by the product may be impaired.
1. Turn off all power supplying this device and the equipment in which it is
installed before working on the device or equipment.
2. Always use a properly rated voltage sensing device to confirm that all
power is off.
3. Connect the CT output leads to the meter inputs. The white wire is the x1
lead. An arrow points to the load side.
4. Release the clasp on one side of the CT and open it on the hinge.
5. Fit the Rogowski coil around the conductor, bringing the coil ends
together.
6. Lock the coil by turning the ring clockwise as shown in the diagram
at right.
7. Reconnect power to the panel.
©2018 Veris Industries USA 800.354.8556 or +1.503.598.4564 / support@veris.com
Other companies' trademarks are hereby acknowledged to belong to their respective owners.
8 ft. (2.45 m)
7.7 ft. (2.35 m)
0.33 in. (8.3 mm)
12 in. (300 mm)
18 in. (460 mm)
24 in. (600 mm)
36 in. (900 mm)
TM