Element4 POWERFAN MKII Installation & User Manual

Element4 POWERFAN MKII Installation & User Manual

Advertisement

Quick Links

INSTALLATION & USER MANUAL
P O W E R F A N M K I I
P L E A S E L E AV E T H I S M A N UA L W I T H T H E F I R E P L AC E FO R F U T U R E R E F E R A N C E

Advertisement

Table of Contents
loading

Summary of Contents for Element4 POWERFAN MKII

  • Page 1 INSTALLATION & USER MANUAL P O W E R F A N M K I I P L E A S E L E AV E T H I S M A N UA L W I T H T H E F I R E P L AC E FO R F U T U R E R E F E R A N C E...
  • Page 3: Preface

    CSA 2.22 Edition: 2014/02/01 CSA P.4.1: 2015 Ed.3 In connection with the CE inspection, the PowerFan MkII should only be sold as a set and not as individual parts. This declaration loses its validity when changes to the device are made without written permission of Element4.
  • Page 5: Table Of Contents

    I N STA L L AT I O N A N D US E R M A N UA L CONTENTS PREFACE CE DECLARATION 1 INSTALLATION Delivery check Points of attention during installation Assembly Flue material Terminals Fire safety 2 LOCATION OF THERMINALS Vertical terminal location (C11) Horizontal terminal location (C31) 3 FLUE SYSTEM...
  • Page 6: Installation

    When the PowerFan is not connected to the receiver of the fireplace, it will function as a regular fan when connected to the It is recommended that the PowerFan MkII be placed in a room socket. It is therefore important to check that the PowerFan is that is large enough for the PowerFan to be removed without correctly connected.
  • Page 7: Flue Material

    The performance declaration provides more information on this (see Table 1.1). Table 1.1 PowerFan Gaspipe to MkIII Burner Gas Block Module Receiver Figure 1.2 - Mounting possibilities PF MkII Figure 1.3 - Connection scheme PowerFan MkII...
  • Page 8: Terminals

    I N STA L L AT I O N A N D US E R M A N UA L 1.5 Terminals For the proper functioning of your PowerFan, the supply of air and the discharge of combustion gases must not be impeded. You can end up both horizontally (by means of a wall terminal) and vertically (by means of a roof terminal).
  • Page 9: Fire Safety

    Figure 1.7 - Roof terminal supplies and ventilation option for the inner pipe. Note: Please make sure that no heat bridges can occur by brackets around the concentric or single-tube material. Figure 1.8 - Ventilation around PowerFan MkII...
  • Page 10: Location Of Therminals

    I N STA L L AT I O N A N D US E R M A N UA L 2 LOCATION OF THERMINALS 2.1 Vertical terminal location (C11) 2.2 Horizontal terminal location (C31) Terminal position Distance Terminal 1,2 of 3 Directly below an opening, ventilation stone, On the same roof level >...
  • Page 11: Flue System

    = Concentric channel Diameter is Ø200/130 mm or Ø150/100 mm Figure 3.1 - Adapter 200/130 Note: In the event that a PowerFan MkII is applied to a fireplace Adapter 200/130 with a Ø150/100 flue connection, the flue must be increased Ø1 to Ø200/130 on the supplied adapter / splitter or a separate...
  • Page 12: Configurations

    I N STA L L AT I O N A N D US E R M A N UA L 3.2 Configurations With the PowerFan MkII, the discharge of the fireplace can be constructed in two ways, respectively directly with separate supply and discharge and with a (partially) concentric structure.
  • Page 13 I N STA L L AT I O N A N D US E R M A N UA L ( 2 ) ( 1 ) Figure 3.3 - Adapter directly on the fireplace and with Figure 3.4 - Roof terminal with horizontal terminal in a different area direct split by adapter ( 2 )
  • Page 14: Calculating The Length Of The Flue

    I N STA L L AT I E H A N D L E I D I N G 3.3 Calculating the length of the flue 3.3.1 Flue construction - type 1 figure 3.10) Immediate split supply and removal (See Maximum discharge lengths for the When air supply and flue gas discharge are split directly on the fireplace, the total length of both may cover 40 meters with the...
  • Page 15 I N STA L L AT I O N A N D US E R M A N UA L Flue lengths construction - type 2.2 figure 3.12) Partial concentric flue - size Ø200 / 130 (See In this situation, a part of the flue is executed concentrically, after which the supply and discharge are split and end up separately.
  • Page 16: Extra Resistance In The Channel

    I N STA L L AT I E H A N D L E I D I N G 3.4 Extra resistance in the channel 90° 45° As with a regular, non-mechanical flue situation, adding bends in the flue configuration of the PowerFan also provides extra resistance.
  • Page 17: Sample Flue Configuration Calculation

    I N STA L L AT I E H A N D L E I D I N G 3.5 Sample flue configuration calculation 20 m 10,5 m 20,5 m 6,25 m Step 1 19,25 m 11 m 12,5 21 m Consider which flue configuration is required 1,5 m 19 m...
  • Page 18 I N STA L L AT I O N A N D US E R M A N UA L 3.5.1 Example Step 1 Figure 3.16 Table 3.3. See the desired setup in The first part of the flue is designed concentrically, after which the supply and flue are split.
  • Page 19: Condensation

    I N STA L L AT I O N A N D US E R M A N UA L 3.6 Condensation If the entire flue configuration is more than 15 meters or if it is expected that condensation will otherwise occur in the flue, e.g. figure 3.17) when a large horizontal flue stretch is present...
  • Page 20: Adjusting The Powerfan

    The fan checks the system for correct operation for 60 seconds. If the system works properly, the blinking stops and the LED stays green Figure 4.1 - Service cover PowerFan MkII LED flashes red If the green light does not stop blinking or changes to red, increase the fan speed by 1 step and observe the waiting time of 60 seconds again.
  • Page 21: Function Of The Remote

    I N STA L L AT I O N A N D US E R M A N UA L 5 FUNCTION OF THE REMOTE 6 TECHNICAL DATA By pressing the "Start button" (top left buttom) the fireplace and The following specifications apply to every Element4 PowerFan the PowerFan will start simultaneously. MkII Note:...
  • Page 22: Technical Drawings

    I N STA L L AT I O N A N D US E R M A N UA L 7 TECHNICAL DRAWINGS Figure 7.1 - Dimensions of the adapter...
  • Page 23 I N STA L L AT I O N A N D US E R M A N UA L Figure 7.2 - Dimensions PowerFan MkII...
  • Page 24 E L E M E N T 4 B .V. Paxtonstraat 23 8013 RP Zwolle The Netherlands Info@element4.nl www.element4.nl R E L E A S E DAT E | 0 9 / 0 7 / 1 9...

Table of Contents