World Wide Web: www.forcecomputers.com Headquarters The Americas Europe Asia Inc. GmbH Japan KK ORCE OMPUTERS ORCE OMPUTERS ORCE OMPUTERS 2001 Logic Drive Prof.-Messerschmitt-Str. 1 Miyakeya Building 4F San Jose, CA 95124-3468 D-85579 Neubiberg/München 1-9-12 Hamamatsucho U.S.A. Germany Minato-ku, Tokyo 105 Japan Tel.: +1 (408) 369-6000 Tel.: +49 (89) 608 14-0...
(Section 3, “Configuration and Connections”) • rack mount installation guidelines (Section 4, “Rack Mounting”) • power requirements and equipment specifications (Section 5, “Requirements and Specifica- tions”) • a copy of the Force Computers Product Error Report. Publication History Revision Date...
Page 9
Preface Centellis CT Series 16000 User’s Manual WARNING Danger: personal injury or equipment damage possible. CAUTION Warning: no danger to people, but equipment damage or loss of data possible. IMPORTANT Special Message: important product features, instructions, and user tips and information.
Centellis CT Series 16000 User’s Manual Introduction 1.0 Introduction General Information The Centellis CT Series 16000 is a CompactPCI, rackmountable system chassis that offers a cost- effective CompactPCI environment suitable for the U.S., European, and Asian marketplaces. The chassis’s rugged construction and integral mounting points provide the high quality and versatility necessary for peak product performance.
Introduction Centellis CT Series 16000 User’s Manual 6 U E x p a n s i o n S l o t s 6 U E x p a n s i o n S l o t s Serviceable Fan Module Figure 1: Centellis Internal Modules (Chassis Front View) Pending receipt of graphic from Pocheng.
Centellis CT Series 16000 User’s Manual Introduction System Features CompactPCI and the H.110 CT bus, the primary technologies of the Centellis CT Series 16000, provide high-speed performance, manageability, and flexibility for growing telephony applica- tions. Key hardware and software features include: •...
Introduction Centellis CT Series 16000 User’s Manual Chassis Modular Components The Centellis CT Series 16000 chassis contains four functional hardware modular components. Each component mounts in or to the Centellis chassis frame. The modular components of a Centellis CT Series 16000 chassis are: •...
Use ferrite bead on the following cables: parallel, serial, Ethernet, mouse, and keyboard. Wind the cable around the ferrite bead one full turn. • FORCE COMPUTERS, Inc. is not responsible for regulatory compliance or malfunction of any user-modified product. 20000325 420 000 AB...
Installation Centellis CT Series 16000 User’s Manual CAUTION ESD PRECAUTIONS - Static Destroys Products • The chassis contains static-sensitive devices. Good static control procedures should be used when installing, removing, and handling all components. Use an antistatic wrist strap at all times. Never touch the board components with any conductive objects.
Centellis CT Series 16000 User’s Manual Installation CPCI-720 Processor Board 14 6U User I/O Slots CPCI-720 Processor Board 5.25” Drive Bay 19” or 23” Rackmount 14 6U User Flange I/O Slots Pluggable Fan Tray 5.25” Drive Bay with Air Intake 19”...
Installation Centellis CT Series 16000 User’s Manual Chassis Rear Description The back of the Centellis 16000 chassis contains two seven-slot user I/O segments, two 80mm transition boards, two hot swappable power supplies, and a power connector (with chassis On/Off and AC switches). Figure 5 shows the rear of the chassis and the rear-accessible modules. Top rear air exhaust 16 slot...
Ethernet address, the host ID address, and all other RTC/NVRAM contents may be lost. Contact Force Computers before ten years of actual battery use have elapsed. There is a danger of explosion if the battery is incorrectly replaced. Replace the...
Installation Centellis CT Series 16000 User’s Manual battery only with the same or an equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions. Force Computers strongly suggests that only authorized service personnel exchange the RTC/NVRAM and the lithium battery.
Centellis CT Series 16000 User’s Manual Installation For hard disk drives, mount the drive onto the HDD mounting bracket with • a 6/32" x 1/4" Phillips pan head screw, a #6 split lock washer, and a #6 flat washer at each of the four positions. Do not mount this assembly to the peripheral tray yet;...
Installation Centellis CT Series 16000 User’s Manual 2.10.2 Powering Up 1. Connect the power cable to the AC connector. 2. Turn on each power supply switch. (This is the black switch on each power supply.) 3. Turn on the green power switch at the back of the chassis. After a few seconds, a message will appear on the connected monitor.
Centellis CT Series 16000 User’s Manual Chassis Layout and Interconnection 3.0 Configuration and Connections The Centellis CT Series 16000 is a CompactPCI-based system chassis designed for CompactPCI in an industrial environment. The 16000’s modularity ensures easy operation, flexibility, and easy rack mounting.
Chassis Layout and Interconnection Centellis CT Series 16000 User’s Manual 3.2.1 Serial COM Port Devices There are two serial com ports: Com 1 and Com 2. Com 1 is located on the front and rear panels of the Centellis chassis, while Com 2 is only found on the chasis rear. Serial devices that may be at- tached to these ports include printers, terminals, and modems.
Centellis CT Series 16000 User’s Manual Chassis Layout and Interconnection 3.2.2 Ethernet Interface (RJ-45) Connector The Ethernet Interface, an RJ-45 connector, provides both 10 Mbit (10Base-T) and 100 Mbit (100Base-TX) protocols. The Ethernet interface uses autosensing circuitry to switch between 10 Mbit and 100 Mbit operation.
Chassis Layout and Interconnection Centellis CT Series 16000 User’s Manual 3.2.3 Keyboard Interface Connector The Keyboard Interface allows interfacing to standard PS/2-style keyboard devices. The connector pin-outs are shown in Figure 9, and the pin functions are provided in Table 5. Keyboard connectors are located on the front and the rear panel of the chassis.
Centellis CT Series 16000 User’s Manual Chassis Layout and Interconnection 3.2.4 Mouse Port Connector The Mouse Port Interface allows the hookup of PS/2-style mouse devices. The connector pin-outs are shown in Figure 10, and the pin functions are provided in Table 6. Mouse connectors are located on the front and read panels of the chassis.
Chassis Layout and Interconnection Centellis CT Series 16000 User’s Manual A (Centronics) and Type B (25-pin D-shell) printer connectors. Printer ports are located on the front and rear panels of the 16000 chassis. CAUTION Using both the front-panel and rear-panel I/O connectors simultaneously may cause system damage.
Centellis CT Series 16000 User’s Manual Chassis Layout and Interconnection 3.2.6 AC Power Connector Figure 12 illustrates the chassis AC power connector located at the lower left rear of the chassis. Table 8 identifies the function of each power plug connector pin. Figure 12: AC Power Connector AC Power Connector Table 8:...
Chassis Layout and Interconnection Centellis CT Series 16000 User’s Manual SVGA Video Interface Table 9: Function Green Blue Not Used Ground Red Return Green Return Blue Return Ground Not Used Not Used Horiz. Sync. Vert. Sync. Not Used SCSI Connections SCSI allows the connection of the system unit to external storage units, such as hard disks, cartridge tapes, and compact disk drives.
Page 32
Centellis CT Series 16000 User’s Manual Chassis Layout and Interconnection Wide SCSI-2 Pin-out Table 10: Signal Name Signal Name Number Number Ground SCD12* Ground SCD13* Ground SCD14* Ground SCD15* Ground SCDPH* Ground SCD0* Ground SCD1* Ground SCD2* Ground SCD3* Ground SCD4* Ground SCD5*...
Centellis CT Series 16000 User’s Manual Chassis Layout and Interconnection 3.3.1 SCSI Bus Cable Length Guidelines The SCSI standard sets a maximum of 6.0 meters total length for all SCSI signals. The internal SCSI bus length on the Centellis system chassis is 0.68 meters maximum. For specific information about installing SCSI devices consult the manual that comes with the device.
Centellis CT Series 16000 User’s Manual Chassis Layout and Interconnection 3.4.2 J3: Backplane I/O Connector J3 is a user-defined I/O connector on the Centellis backplane. For pin-out information, consult the appropriate CompactPCI PICMG specifications. 3.4.3 J4 Backplane I/O Connector The J4 connector is used for the H.110 bus. This connector is a 220-pin 2 mm x 2 mm female connector for a 2mm interface.
Page 37
Chassis Layout and Interconnection Centellis CT Series 16000 User’s Manual Page 28 20000325 420 000 AB...
Adequate space must always exist around the fans and the air inlets and outlets for successful airflow. Allow at least 3-1/2" at the front and back of the chassis, and do not cover the side vents. 20000325 420 000 AB Page 29 FORCE COMPUTERS 15172101 420 000 AAPage 29...
Page 39
Rack Mounting Centellis CT Series 16000 User’s Manual Page 30 20000325 420 000 AB FORCE COMPUTERS...
Centellis CT Series 16000 User’s Manual Specifications 5.0 Requirements and Specifications Chassis Identication A system chassis identification label is attached to the lower right side of the chassis. The label provides the following chassis information: • Serial number (bar coded) •...
Specifications Centellis CT Series 16000 User’s Manual 5.2.2 Peripheral Tray Modules Table 16 provides power consumption values for the peripheral tray modules. Power Consumption (Typical Values) Table 16: Device +12V -12V +3.3 Hard Disk Drive 500 mA 1.2 A CD-ROM 400 mA 1.8 A Floppy Disk Drive...
Centellis CT Series 16000 User’s Manual Specifications Safety and Emissions Certification The Centellis CT Series 16000 chassis is tested and certified to the following specifications: • FCC part 15 Class A • UL 1950 (Third Edition, 1995) • CAN/CSA C22.2 No. 950-95 •...
PRESENT DATE: AFFECTED PRODUCT: AFFECTED DOCUMENTATION: HARDWARE SOFTWARE SYSTEMS HARDWARE SOFTWARE SYSTEMS ERROR DESCRIPTION: THIS AREA TO BE COMPLETED BY FORCE COMPUTERS: DATE: PR#: RESPONSIBLE DEPT.: MARKETING PRODUCTION ENGINEERING BOARD SYSTEMS Send this report to the nearest F headquarters listed on the back...