Download Print this page

Hatco FTBR-1 Manual page 2

Remote drop-in frost tops
Hide thumbs Also See for FTBR-1:

Advertisement

Ordering Instructions:
Please specify the following with
each order:
1. Desired Voltage:
120 or 220-240V
2. Number of Full-Size
Sheet Pans Accommodated:
1-, 2-, 3-pan as rectangular,
sheet pan with Slim or
Standard configuration
Model FTBR-1, -2, -3
FTBX-1, -2, -3
FTBR-1, FTBX-1: 28.94" (735 mm)
FTBR-2, FTBX-2: 39" (991 mm)
FTBR-3, FTBX-3: 57" (1448 mm)
FTBR-1, FTBX-1: 28.94" (735 mm)
FTBR-2, FTBX-2: 39" (991 mm)
FTBR-3, FTBX-3: 57" (1448 mm)
.84"
(21 mm)
5.05"
.84"
(128 mm)
(21 mm)
Solenoid Valve
(FTBX only)
5.05"
(128 mm)
(FTBX only)
Solenoid Valve
Model FTBR-S2, -S3
FTBX-S2, -S3
.84"
(21 mm)
5.05"
.84"
(128 mm)
(21 mm)
Solenoid Valve
(FTBX only)
5.05"
(FTBX only)
(128 mm)
Solenoid Valve
(FTBX only)
(FTBX only)
All Models
Control Panel
May be field mounted
up to 9' (2.7 meters)
8.188"
from unit
(208 mm)
6.5"
(165 mm)
Minimum:
(A)
11.36" (289 mm)
Maximum:
Well Opening
11.81" (300 mm)
(B)
Minimum: 13.64" (347 mm)
Maximum:17.38" (442 mm)
Form No. FTBR, FTBX Spec Sheet
Remote Drop-In Frost Tops
Models: FTBR-1, -2, -3, -S2, -S3, FTBX-1, -2, -3, -S2, -S3
3. Remote Refrigeration:
Note: Shipped loose: Frost Top, Control
Panel (Probe wires are 9 feet [2.7 meters])
and a TXV valve
A. FTBR with a condensing unit - may be
field mounted up to 50' (15.24 meters) of
tubing from the unit - that is
shipped loose
(FTBX only)
(FTBX only)
FTBR-S2, FTBX-S2: 54.94" (1395 mm)
FTBR-S3, FTBX-S3: 80.81" (2053 mm)
FTBR-S2, FTBX-S2: 54.94" (1395 mm)
FTBR-S3, FTBX-S3: 80.81" (2053 mm)
4.523"
(115 mm)
Cutout Dimensions for Remote Frost Tops
Model
Minimum Width (A)
FTBR-1, FTBX-1
27.44" (697 mm)
FTBR-2, FTBX-2
37.375" (949 mm)
FTBR-3, FTBX-3
55.375" (1407 mm)
Minimum: 10.75" (273 mm)
Maximum: 12.09" (307 mm)
FTBR-S2, FTBX-S2
53.31" (1354 mm)
FTBR-S3, FTBX-S3
79.19" (2011 mm)
HATCO CORPORATION
l
(800) 558-0607
(414) 671-6350
3.06"
(77 mm)
3.06"
(77 mm)
.5"
No drain on
(13 mm)
FTBR-1 or FTBX-1
.5"
No drain on
(13 mm)
FTBR-1 or FTBX-1
FRONT VIEW
FRONT VIEW
FRONT VIEW
FRONT VIEW
Model FTBR only
Condensing Unit
May be field mounted up to
50' (15.24 meters) from unit
Field
Connection
4.87"
Location
(124 mm)
6.75"
(171 mm)
9.125"
(232 mm)
Maximum Width (A)
28" (711 mm)
38" (965 mm)
56" (1422 mm)
54" (1372 mm)
79.875" (2029 mm)
l
P.O. Box 340500 Milwaukee, WI 53234-0500 U.S.A.
l
l
www.hatcocorp.com
support@hatcocorp.com
Page 2 of 3
B. FTBX without a condensing unit
(Solenoid Valve attached to Frost Top)
FTBR-1 FTBX-1: 21.06" (535 mm)
FTB-2,-3 FTBX-2,-3: 28.94" (735 mm)
FTBR-1 FTBX-1: 21.06" (535 mm)
FTB-2,-3 FTBX-2,-3: 28.94" (735 mm)
.84"
(21 mm)
SIDE VIEW
.84"
(21 mm)
SIDE VIEW
3.06"
(77 mm)
3.06"
Field
(77 mm)
.5"
Connection
4.87"
(13 mm)
Location
(124 mm)
.84"
.5"
(21 mm)
(13 mm)
.84"
(21 mm)
6.75"
(171 mm)
9.125"
(232 mm)
11.36" (289 mm)
13.64" (347 mm)
Minimum Depth (B)
Maximum Depth (B)
19.44" (494 mm)
20.125" (511 mm)
27.31" (694 mm)
28" (711 mm)
27.31" (694 mm)
28" (711 mm)
19.44" (494 mm)
20.125" (511 mm)
19.44" (494 mm)
20.125" (511 mm)
FTBR-S2,-S3, FTBX-S2,-S3:
21.06" (535 mm)
FTBR-S2,-S3, FTBX-S2,-S3:
21.06" (535 mm)
SIDE VIEW
SIDE VIEW
10.75" (273 mm)
May 2019