Electrical Specification
220 - 240V
Wiring notes
Installation should only be carried put by a competent person and in accordance with the
current edition of the IEE Wiring Regulations (BS7671: Requirements for Electrical
Installations) and any other applicable statutory regulations.
The heater(s) must be earthed.
The heater(s) should be preceeded by an all pole isolating switch.
Where the heater(s) are installed outdoors, or where water is present they must be
protected by a 30mA Residual Current Device (RCD).
The heater is protected to IP55 and is suitable for outdoor use. All cabling, cable glands,
etc. must have a minimum rating of IP55.
The heater should be mounted horizontally where possible or at a
maximum angle of 30 degrees from
brackets provided to ensure adequate clearances.
If mounted under a parasol ensure the heater is left to completely cool
before closing.
A minimum air gap of 500mm should always be allowed between the top
of the heater and the ceiling, roof or parasol.
A safety distance of 1 mtr should always be left in front of the heater.
Heaters should not be installed in areas where hazardous vapours may be
present as defined in BS5345
Ensure that there is no possibility of inflammable material coming into
contact with the heater.
This product conforms to EU Directive 2002/96/EC.
This appliance bears the symbol of the crossed waste bin. This
indicates that, at the end of its useful life, it must not be disposed
of as domestic waste, but must be taken to a collection centre for
waste electrical and electronic equipment.
responsibility to dispose of this appliance through the appropriate
channels at the end of its useful life. Failure to do so may incur
the penalties established by laws governing waste disposal.
1500W
6.5A
IP55
the horizontal using the mounting
It is the user's
W. Tombling Ltd
Outdoor Infra-red Heater
HLW1500
1500w
W. Tombling Ltd
Wembley House
Dozens Bank
West Pinchbeck
Spalding
Lincolnshire
PE11 3ND
Tel +44 (0) 1775 640049
Fax +44 (0) 1775 640050
www.tombling.com
PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE
INSTALLATION AND RETAIN THEM FOR FUTURE
220 - 240V

Advertisement

loading

Summary of Contents for W. Tombling HLW1500

  • Page 1 Electrical Specification W. Tombling Ltd 220 - 240V 1500W 6.5A IP55 Outdoor Infra-red Heater Wiring notes Installation should only be carried put by a competent person and in accordance with the current edition of the IEE Wiring Regulations (BS7671: Requirements for Electrical Installations) and any other applicable statutory regulations.
  • Page 2 After unpacking make sure that the appliance is complete and shows no signs of visible damage or tampering. • Keep the packing materials away from children. Wall mounting • Check the supply voltage is the same as indicated on the heater. Remove the bracket from the back of the heater by unscrewing the 2 x M8 bolts.