TEMPERATURE AND HUMIDITY CONTROLLER
FOR ONE-BATTERY AIR HANDLING UNIT
C BUS
DTU 614
C2 Eng.
• Temperature and relative humidity control in air handling units
• 24-hour, 7-day, and yearly period programming
• Communication systems:
– telemanagement C-Bus
• 24 V power supply; DIN rail mounting
1. APPLICATION
DTU 614 is designed for temperature and humidity control in air handling units composed of:
• 1 hot/chilled water or vapor battery with 3-wire modulating control
or
or
• 1 adiabatic humidifying unit with On-off control
or
• 1 air mixing unit with 0...10 V– air damper actuators
or 1 heat recuperator with 0...10 V– or On-Off control (CSV 304 converter).
The equipment can be included in a Telemanagement system through the C-Bus connection.
2. FEATURES
The main features of DTU 614 are as follows:
• One 3-wire modulating output, or 2-stage On-off (two equal loads) or 3-stage (two unequal loads) outputs,
configurable for:
– room temperature control (heating or cooling) with summer external compensation if desired, minimum
and maximum flow limits to prevent cold drafts, hot air stratification and condensing in the air ducts.
– flow temperature control (heating or cooling) with winter and summer compensation if desired
– pre-heating temperature control at variable values according to room temperature and humidity
– battery antifreeze temperature control
– One On-off output for winter adiabatic humidifying unit control
• One 0...10 V– progressive output, configurable for:
– air mixing control based on temperature comparison, with minimum external air limit
– external air control for room dehumidification with compensation of dew temperature on glass windows and
with minimum external air limit
– heat recuperator On-Off control according to room-external temperature comparison
– vapor-operated humidifier setting by means of a 0...10 V– control
• One 3-wire On-Off output for manual or automatic seasonal switching.
• Two On-Off outputs for fan and pump control according to time setting in use
• Winter battery frostprotection temperature control
• Time setting including 25 24-hour programs, 5 7-day programs, and 25 yearly period programs
• Alarms for detector short and open circuits and for system and equipment malfunction.
3. ACCESSORIES
No.
Description
1
Duct flow air temperature detector
1
Duct outside air temperature detector
or
wall outside air temperature detector SAE 001
1
Duct extract air temperature detector
or
room air temperature detector
1
Duct pre-heating temperature detector
or
dew point temperature detector
1
Room relative humidity and temperature detector
or duct relative humidity detector
or duct relative humidity detector (swimming pools) SUR 051
1
Battery frostprotection temperature detector – flush SAF 010
or
immersed
1
0...10 V – to 2-stage On-Off Duct converter
1
Temperature set-point adjuster
1
Relative humidity set-point adjuster
1
Outside air minimum distance positioner
We reserve the right to make changes without notice
COSTER
electric batteries with 1-,2-, or 3-stage On-Off control
direct expansion batteries with 1- or 2-stage On-Off control
vapor-operated, with 0...10 V– control (alternative to air damper control)
STA 010
STA 001
STA 010
SAB 010
STA 010
STV 010
SAU 012
SUR 012
SIH 010
CSV 304
CDB 100
CDB 200
PCS 04
Type
Application Range
0...60 °C
–30...+40 °C
–30...+40 °C
0...40 °C
0...40 °C
0...40 °C
0...40 °C
0...40 °C ; 20...80 %
20...80 %
10...90 %
0...40 °C
0...40 °C
± 5 °C
± 5 %H
E 121 - DTU 614
C2 Eng. 04.07.01
E 121
04.07.01
Code Data sheet
Sensing element t°
NTC 10 kΩ
B1
NTC 1 kΩ
B2
NTC 1 kΩ
B2
NTC 10 kΩ
B3
NTC 10 kΩ
B3
NTC 10 kΩ
B4
NTC 10 kΩ
B4
NTC 10 kΩ
B3-B6
B6
B6
NTC 10 kΩ
B7
NTC 10 kΩ
B7
U1
Rt°
RH
Rs
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DTU 614 C2 Eng. and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Coster DTU 614 C2 Eng.

  • Page 1 COSTER E 121 - DTU 614 C2 Eng. 04.07.01 E 121 TEMPERATURE AND HUMIDITY CONTROLLER 04.07.01 FOR ONE-BATTERY AIR HANDLING UNIT C BUS DTU 614 C2 Eng. • Temperature and relative humidity control in air handling units • 24-hour, 7-day, and yearly period programming •...
  • Page 2: Technical Data

    COSTER E 121 - DTU 614 C2 Eng. 04.07.01 4. TECHNICAL DATA default values in bold print • Electrical data Temp. proportional band (base value): ± 24 V ~ ± 10% ± 1… 2 …± 40 °C Power supply Heating (room) (B3 o B1+B3) ±...
  • Page 3: Wiring Diagram

    COSTER E 121 - DTU 614 C2 Eng. 04.07.01 7. WIRING DIAGRAM 24 V Y : MODULAT I NG 3-Wire Modulating Valve Control Run t i me : x x x s B1 – Flow air temp. detector 0…60 °C B2 –...
  • Page 4 COSTER E 121 - DTU 614 C2 Eng. 04.07.01 8. WIRING Procede as follow : • Separate the base from the cover • Install the base onto the DIN rail and check that it is properly anchored by the securing elements (5.
  • Page 5 COSTER E 121 - DTU 614 C2 Eng. 04.07.01 10. COMMUNICATION C-Bus Telemanagement Communication (for more detailed information please see Technical Sheet T 021) Through the C-Bus output, DTU 614 can be managed remotely (two-way data communication) by means of one or more local PC(s) and/or a remote central computer via telephone network.
  • Page 6 COSTER E 121 - DTU 614 C2 Eng. 04.07.01 11. TEMPERATURE AND HUMIDITY CONTROL – EXAMPLES – Room temperature and humidity control B2 – Outside temp. detector (for compensation only) B3 – Room or extract temp. detector B6 – Room or extract humidity detector DTU 614 Rt°...
  • Page 7 COSTER E 121 - DTU 614 C2 Eng. 04.07.01 12. USE OF YS OUTPUT– EXAMPLES – Temperature comparison air damper optimization B2 – Outside temp. detector 24 V B3 – Room or extract temp. detector Ys – Progressive air damper control Rs –...
  • Page 8 COSTER E 121 - DTU 614 C2 Eng. 04.07.01 13. USE OF Y OUTPUT– EXAMPLES – 1 Preheating modulating battery – 1 Humidifying On-Off unit 24 V B1 – Flow temp. detector B2 – Outside temp. detector (for compensation) B3 – Room or extract temp. detector B6 –...
  • Page 9 COSTER E 121 - DTU 614 C2 Eng. 04.07.01 – 1 Winter heating, summer cooling modulating battery with heat pump season switching – 1 Humidifying On-Off unit 24 V B1 – Flow temp. detector B2 – Outside temp. detector (for compensation) B3 –...
  • Page 10 COSTER E 121 - DTU 614 C2 Eng. 04.07.01 – 1 Winter preheating modulating battery with antifreeze control – 1 Summer cooling/dehumidifying modulating battery – 1 Winter post-heating modulating battery – 1 Summer post-heating On-Off battery – 1 Humidifying On-Off unit B1 –...
  • Page 11: Operation

    COSTER E 121 - DTU 614 C2 Eng. 04.07.01 15. OPERATION DTU 614 is a microprocessor-operated digital controller for temperature and relative humidity control in air handling units composed of: – 1 unit with 3-wire modulating control, or 1, 2 or 3-stage On-Off control. The unit can have the following functions: Preheating;...
  • Page 12 COSTER E 121 - DTU 614 C2 Eng. 04.07.01 Pb Dampe r s Pb Air damper = Pb room heating x 1.0 (= ± 2 °C) Pb He a t Ro om x 1 . 0 d T Re c up e r a t o r = DT recuperator = Pb room heating x 1.0 (=±...
  • Page 13 COSTER E 121 - DTU 614 C2 Eng. 04.07.01 Operating modes The controller can operate in the following modes: – ON Winter; OFF Winter – ON Summer; OFF Summer Cu r r e n t mod e – ON ; OFF W i n t e r depending on: : –...
  • Page 14 COSTER E 121 - DTU 614 C2 Eng. 04.07.01 17. OUTSIDE COMPENSATION OF TEMPERATURE Compensation functions are only enabled if the outside detector B2 is connected. Such functions can be as follows: • Compensation of desired flow Heating and Cooling temperatures;...
  • Page 15 COSTER E 121 - DTU 614 C2 Eng. 04.07.01 18. RELATIVE HUMIDITY CONTROLLER The function is only enabled if detector B6 is connected. De t e c t o r s L a y ou t – – – – – 6 – 8...
  • Page 16: Heat Pump Control

    COSTER E 121 - DTU 614 C2 Eng. 04.07.01 20. FROSTPROTECTION TEMPERATURE CONTROL De t e c t o r s L a y ou t The function is only enabled if detector B7 is connected . 100% – – – – – – 7 –...
  • Page 17: Control Outputs

    COSTER E 121 - DTU 614 C2 Eng. 04.07.01 22. CONTROL OUTPUTS Control output Y Outputs Y can be configured as: 100% • Y - MODULATING = modulating control for 3-wire valves or 3-wire signal converters into 0...10 V– or step controllers.
  • Page 18 COSTER E 121 - DTU 614 C2 Eng. 04.07.01 23. OUTPUT Ys Output Ys with 0...10V– control signal is only enabled when the Mv fan is operating, and can be used for: – AIR DAMPER TEMP. = air damper control based on temp. comparison –...
  • Page 19 COSTER E 121 - DTU 614 C2 Eng. 04.07.01 24. SEASON SWITCHING The controller switches the action of output Y and the position of season control Ysc depending on the selection: NO; WINTER; SUMMER; THROUGH ss CONTROL; THROUGH ss + c1 CONTROL;...
  • Page 20 COSTER E 121 - DTU 614 C2 Eng. 04.07.01 25. DATE-TO-DATE PERIOD PROGRAMS DTU 614 can start and shut down the air handling using: – 25 24-hour programs – 5 7-day programs – 25 date-to-date period programs Assigning the program...
  • Page 21: Complementary Functions

    COSTER E 121 - DTU 614 C2 Eng. 04.07.01 26. COMPLEMENTARY FUNCTIONS Password Password selection and enabling. The command disables the use of keys + and –, so that data cannot be modified. Enter the number (1900... 1999) using the + and – keys.
  • Page 22 COSTER E 121 - DTU 614 C2 Eng. 04.07.01 27. ALARMS The controller processes two types of alarms: – alarms related to functional irregularities affecting the controller (LED 6.11) and the controlled systems (led 6. ) and the controlled systems (led 6.
  • Page 23 COSTER E 121 - DTU 614 C2 Eng. 04.07.01 29. SEQUENCE OF DISPLAY PAGES ( data and functions as stored at delivery S i t e - - - - - - - - - - - - P r o g r am Wi n t e r...
  • Page 24 COSTER E 121 - DTU 614 C2 Eng. 04.07.01 M0. NORMAL USE Ref. Display Description Notes Sect. S i t e - - - - - - - - - - - - Site name. Set in M3. R t : 2 0 . 0 c...
  • Page 25 COSTER E 121 - DTU 614 C2 Eng. 04.07.01 M0. NORMAL USE Ref. Display Description Notes Sect. Mu - HUMI D I F . : 1 0 0% Output Mu load: humidification FROSTPROT . : 1 0 0% Battery antifreeze function load 1 2 .
  • Page 26 COSTER E 121 - DTU 614 C2 Eng. 04.07.01 M2. ADJUSTMENT Ref. Display Description Notes Sect. Heating proportional band in ± °C. T empe r . Room Based on this value the controller derives other ± If B3 or B1 and B3 are configured P r op .
  • Page 27 COSTER E 121 - DTU 614 C2 Eng. 04.07.01 M3. SETTING Ref. Display Description Notes Sect. De t e c t o r s L a y o u t Configuration of connected detectors (outputs B-M) 1 : Flow temp. detector B1.
  • Page 28 Reg. Off. Central & Southern TEMPERATURA Viale G. Marconi, 437 Tel. +39.06.5573330 ENERGIA Fax +39.06.5566517 25048 Edolo (BS) Orders and Shipping Via Gen. Treboldi 190/192 Tel. +39.0364.7732.00/02 CISQ/CSQ cert.n°9115.COEE Fax +39.0364.770016 Web: www.coster.info E-mail: info@coster.info We reserve the right to make changes without notice...

Table of Contents