    7. Important Product & Safety Instructions 8. Warnings 9. Notices 10. Cautions 11. Regulatory Appendix. Configuration Downlink Command Appx. 1 Payload Appx. 2 Configuration Command Appx. 2.1 Payload Appx. 2.2 Command Description Appx. 3 Response Content © 2019 Browan Communications Inc. All rights reserved.
  • Page 3: Specifications

    EU: +17dBm LEDs One blue LED Rx Sensitivity -135dBm 2.7 Additional Features Antenna Gain -2dBi Peak, -5dBi Avg PCB Temperature 2.4 Certifications and Conformity Battery Monitoring FCC ID: 2AMUGTBSP100 IC: 22980-TBSP100 ROHS REACH © 2019 Browan Communications Inc. All rights reserved.
  • Page 4: Operation

    Additionally, the device will send a status message every 10 minutes while in the occupied state and every 1 hour while in the vacant state. © 2019 Browan Communications Inc. All rights reserved.
  • Page 5: Messages

    (4) When the device didn't trigger by the occupied state again within 5 minutes from the last message, status changes from occupied to free mode and send a message. 4.1.2 Payload Port Payload Length 8 bytes Bytes Field Status Battery Temp Time Count © 2019 Browan Communications Inc. All rights reserved.
  • Page 6: Payload (Continue)

    Total count of event-triggered Bits [23:0] unsigned value, range 0 – 16,777,215. *Note: little-endian format. Note: This value is not stored persistently on the device, and may reset whenever the device is power-cycled or rebooted. © 2019 Browan Communications Inc. All rights reserved.
  • Page 7: Battery

    Replace only with the same or equivalent type recommended by the manufacturer. Discard used batteries according to the manufacturer’s instructions. Risk of Explosion if Battery is replaced by an Incorrect Type. Dispose of Used Batteries According to the Instructions. © 2019 Browan Communications Inc. All rights reserved.
  • Page 8: Label Format Information

    Uses a hexadecimal representation resulting in 16 characters. 6.1.3 DevEUI 58A0CBFFFFFEFFFF. Uses a hexadecimal representation resulting in 16 characters 6.1.4 Model number Non-reserved characters(except ":" and space) with a maximum length of 20 characters. © 2019 Browan Communications Inc. All rights reserved.
  • Page 9: Factory Check Code

    ● The GS1 Application Identifier (21) indicates that the GS1 Application Identifier data field contains a serial number. ● The GS1 Application Identifier (92) assigned to the company’s internal information is DevEUI. © 2019 Browan Communications Inc. All rights reserved.
  • Page 10: Important Product & Safety Instructions

    (whether integrated or removable) can cause an explosion or fire. ● Do not dry the sensors or battery with an external heat source such as a microwave oven or hairdryer. © 2019 Browan Communications Inc. All rights reserved.
  • Page 11: Warnings

    If contact has been made, wash the affected area with copious amounts of water and seek medical advice. ● Do not use any charger other than that specifically provided for use with the equipment. © 2019 Browan Communications Inc. All rights reserved.
  • Page 12: Notices

    ​ E XPLOSION Incorrect Type. Dispose of Used Batteries or leakage of flammable liquid or gas. According to the Instructions. Discard used batteries according to the manufacturer's instructions. © 2019 Browan Communications Inc. All rights reserved.
  • Page 13: Regulatory

    11. Regulatory Hereby, Browan Communications Inc. declares that the radio equipment for Tabs products is in compliance with Directive 2014/53/EU. This device complies with Part 15 of the FCC Rules and RSS Standards of Industry Canada. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 14: Appendix. Configuration Downlink Command

    β, range 0 – 15; Bits [16:13] blind time in sec = (β + 1) × 0.5. Default: 15 (8 sec) Bits [24:17] detection threshold, range 0 – 255. Default: 16 Bits [31:25] © 2019 Browan Communications Inc. All rights reserved.
  • Page 15: Appx. 2 Configuration Command

    Occupied interval in sec 2 bytes *Note: little-endian format. (Must be lesser than “keep-alive time”) 0x03 Free detection time in min 1 byte 0x04 Trigger Count in the occupied status 2 bytes *Note: little-endian format. © 2019 Browan Communications Inc. All rights reserved.
  • Page 16: Appx. 2.2 Command Description

    => Occupied override : 0x0258 -> 600 sec 03 05​ => Free detection time : 0x05 -> 5 min => ​ 04 0000​ T rigger Count in the occupied status 05 00148101​ => PIR parameter : 0x01811400 © 2019 Browan Communications Inc. All rights reserved.