Manual for motor FM_VM R5_R7 ( Date of publication 01/2018)
If the engine still does not start, it is necessary to contact an authorized service center or the
manufacturer directly.

7. Running motor

Each motor is factory-tested and adjusted to the basic setting. Use a fuel with a higher ratio of oil
(see section 3 of this manual), ie. 1:25. While running is not recommended long term exceed the
motor speed 2500 / min while controlling the temperature of the engine. Do not keep a constant
speed but motor flush with the occasional addition / slow down the gas. This mode observe about
the first 30 minutes of operation. After a short time, you can gradually increase the speed up to
higher allowed RPM . Total time of run is about 2 hours.

8. Install the motor inside the model

When thinking about the placement of the engine into the model, keep in mind that it is absolutely
necessary to ensure proper cooling. Use all screws to attach the motor to the motor mount. Engine
mount directly without dampers. Use self-locking nuts and / or thread adhesive of medium strength.

9. Transport status of motor

The 250 R5 is delivered due to transport and the risk of damage with the dismantled carburettor.
Preparation of the carburettor for assembly, step 1 to 3.
FIALA PROP s.r.o, Vysoká 56, 75641 LEŠNÁ , Czech Republic , e-mail: info@fialaprop.cz
www.fialaprop.com