CHERUBINI MyRoll Instructions Manual

CHERUBINI MyRoll Instructions Manual

Rolling shutter and awnings control unit

Advertisement

Quick Links

A510062 MyRoll
I
CENTRALINA PER AVVOLGIBILI E TENDE DA SOLE
GB
ROLLING SHUTTER AND AWNINGS CONTROL UNIT
D
FUNKEMPFÄNGER FÜR ROLLLADEN UND MARKISEN
F
RÉCEPTEUR POUR VOLET ROULANT ET STORE
E
CENTRALITA PARA PERSIANA Y TOLDO
ISTRUZIONI - INSTRUCTIONS - EINSTELLANLEITUNGEN - INSTRUCTIONS - INSTRUCCIONES

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MyRoll and is the answer not in the manual?

Questions and answers

Summary of Contents for CHERUBINI MyRoll

  • Page 1 A510062 MyRoll CENTRALINA PER AVVOLGIBILI E TENDE DA SOLE ROLLING SHUTTER AND AWNINGS CONTROL UNIT FUNKEMPFÄNGER FÜR ROLLLADEN UND MARKISEN RÉCEPTEUR POUR VOLET ROULANT ET STORE CENTRALITA PARA PERSIANA Y TOLDO ISTRUZIONI - INSTRUCTIONS - EINSTELLANLEITUNGEN - INSTRUCTIONS - INSTRUCCIONES...
  • Page 3: Safety Instructions

    3- Black opening distance of the contacts of at least 3 mm before the circuit. - The MyRoll control unit was explicitly designed to be installed in a junction box or socket boxes. Is not waterproof and has a ligh impact protection.
  • Page 4 COMPATIBLE REMOTE CONTROLS GIRO GIRO Wall LED - display - STOP DOWN DOWN STOP Channel selector GIRO Plus GIRO Lux GIRO P-Lux Activating/ Deactivating the DISPLAY DISPLAY Sun sensor - Activating the Change channel DISPLAY Change Wind sensor Sun sensor channel is “ON”...
  • Page 5: Key To Symbols

    KEY TO SYMBOLS short motor long motor rotation double short GIRO rotation in one in other direction rotation direction STOP DOWN TECHNICAL FEATURES - Power supply 230 V / 50 Hz - Radio frequency 433,92 MHz - Decoder system Rolling code DOWN - Modulation AM/ASK...
  • Page 6 COMMAND SEQUENCES EXAMPLE As we can see from the example, when the sequence ends positively, the motor returns to its starting position in one long rotation. In fact, Most of the command sequences have three distinct steps, at the two short rotations in the same direction correspond to one long end of which the motor indicates if the step has been concluded rotation in the opposite direction.
  • Page 7 SETTING THE FIRST REMOTE CONTROL This operation can only be performed when the control unit is new, or after a total delete of the memory. RESET/AUX During this step, power up only one control unit at time! max 2 sec The rotation direction can be reversed also by interchanging the T1: First remote control to be set BROWN motor wire with the BLACK motor wire.
  • Page 8 REMOTE CONTROL MEMORY CLEARING FULL MEMORY CLEARING The full memory clearing can be performed in two ways: It is possible to delete each memorized remote control individually. As the last one is deleted the control unit initial condition is restored. The 1) WITH THE REMOTE CONTROL same applies to the single channels of a multichannel remote control: Tn: Already programmed remote control...
  • Page 9: Time-Out Setting

    SWITCH TIME-OUT SETTING It is possible to run the motor through a switch connected to the control unit with a wire (Optional switch). The switch must be equipped with mechanical or electrical 90 s interlock, to prevent two commands being sent simultaneously. Furthermore, the switch must be an unstable pushbutton: Time-out is the time during which the releasing it, the switch opens.
  • Page 10: Compatible Devices

    SET BUTTON go off and then perform this sequence: cod. A520012 SELECTOR NB: During the wind-alarm the led inside the MyRoll blinks. SETTING THE SENSOR 2 sec To associate the sensor to the control unit, a remote control must be For the complete description of the functions of this device see the already memorized.
  • Page 11 WINDTEC - Ref. A520007 tuning Sun-sensor 2 sec WINDTEC LUX - Ref. A520008 tuning For the complete description of the functions of these devices see the NB: During the wind-alarm the led inside the MyRoll blinks. instruction booklet that came in the box.
  • Page 12 WindTec sensor returns to normal operational mode. light intensity goes below the threshold set. It is possible to repeat this During the test mode the led inside the MyRoll is on. test several times, so as to find the desired adjustment levels...
  • Page 13: Eu Declaration Of Conformity

    EU DECLARATION OF CONFORMITY during daily use. Power up the control unit, make sure that no other CHERUBINI S.p.A. declares that the product is in conformity with control units having an empty memory are powered up in the same the relevant Union harmonisation legislation: operating range.
  • Page 16 CHERUBINI S.p.A. Via Adige 55 25081 Bedizzole (BS) - Italy Tel. +39 030 6872.039 | Fax +39 030 6872.040 info@cherubini.it | www.cherubini.it CHERUBINI Iberia S.L. Avda. Unión Europea 11-H Apdo. 283 - P. I. El Castillo 03630 Sax Alicante - Spain Tel.

This manual is also suitable for:

A510062

Table of Contents