Maintenance; Storage; Technical Data - Grizzly HDR 21-150 Translation Of The Original Instructions For Use

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 15
GB
Always keep the washer clean. Do not
use any detergents or solvents.
Always keep the ventilation slots
clean and free.
Only clean the pressure washer with a
soft brush or a slightly moist cloth.
In case a nozzle of the jet tube (17/18)
is clogged up, use the nozzle cleaning
pin (20) to remove the object from the
nozzle.

Maintenance

The pressure washer is maintenance free.
Ask our service centre to carry
out any work that is not de-
scribed in these instructions.
Use only original parts.

Storage

Drain all the water from the pressure
washer.
Disconnect the unit from the water
supply. Press the On/Off switch (10)
to turn on the pressure washer for no
longer than 1 minute until no more
water escapes from the jet gun(1) or
from the attaching parts (17/18). Turn
off the unit.
Protect the pressure washer and its
accessories from frost when they
have not been completely drained of
all water.
Store the pressure washer and its ac-
cessories in a frost-free room.
Waste Disposal and
Environmental Protection
Be environmentally friendly. Return the tool,
accessories and packaging to a recycling
centre when you have finished with them.
Electric appliances should not be
disposed of in the domestic gar-
bage.
22
Hand the tool in at a recycling centre. The
plastics and metal parts can be separated
and recycled. Ask your Service Center
about this.

Technical data

Pressure Washer ................HDR 21-150
Mains connection................230 V~, 50 Hz
Power consumption ...................... 2100 W
Mains cable .........................................5 m
Weight (without accessories) ......... 10,2 kg
Safety class .........................................
Degree of protection .......................... IPX5
Rated/operating pressure (p).........11 MPa
Max. permissible pressure (p max) ..15 MPa
Max. inflow pressure (p in max)... 0.8 MPa
Max. inflow temperature (T in max) ...40°C
Pumping rate, water (Q) .............. 5.5 l/min
Max. pumping rate, water
(Q max) ........................................ 7.5 l/min
Sound pressure level
(L
) ...................... 78.2 dB(A); K
pA
Sound power level
(L
measured ....... 91.7 dB(A); K
guaranteed
............................98.0 dB(A)
Vibration
(a
) ..................... 0.496 m/s
h
Do not exceed the maximum permitted
network impedance of 0.277 Ohms at the
electrical connection point.
The user must ensure that the device is
operated only on a power supply network
that fulfils this requirement.
If necessary, the local power supply com-
pany can be asked for the system imped-
ance.
Technical and optical changes can be car-
ried out in the course of further development
without notice. All dimensions, references
and information of this instruction manual
are therefore without guarantee. Legal
claims, which are made on the basis of the
instruction manual, cannot thus be consid-
ered as valid.
= 3.0 dB
pA
)
WA
= 3.0 dB
WA
; K=1.5 m/s²
2
II

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents