Ametek Land NIR-B Series Pre-Installation Manual

Ametek Land NIR-B Series Pre-Installation Manual

With pneumatic auto retract

Advertisement

NIR-B with Pneumatic Auto Retract
PRE-INSTALLATION GUIDE
PUBLICATION N
812409
O
LANGUAGE: ENGLISH
NIR-B-Glass-90-18-3-25-PAR - Model Nº 812144
i
Q U A L I T Y C U S T O M E R S O L U T I O N S

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NIR-B Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ametek Land NIR-B Series

  • Page 1 NIR-B with Pneumatic Auto Retract PRE-INSTALLATION GUIDE PUBLICATION N 812409 LANGUAGE: ENGLISH NIR-B-Glass-90-18-3-25-PAR - Model Nº 812144 Q U A L I T Y C U S T O M E R S O L U T I O N S...
  • Page 2 IMPORTANT INFORMATION - PLEASE READ Health and Safety Information Read all of the instructions in this booklet - including all the WARNINGS and CAUTIONS - before using this product. If there is any instruction which you do not understand, DO NOT USE THE PRODUCT.
  • Page 3 +91 - 80 67823240 Email: land.enquiry@ametek.com Email: land.enquiry@ametek.com Web: www.landinst.com Web: www.landinst.com For further details on all AMETEK Land offices, distributors and representatives, please visit our websites. Contact SVA Industrie Fernseh GmbH Marie-Curie-Straße 11 40721 Hilden Germany Tel.: +49(0)21 03–33 55 00 Fax: +49(0)21 03–33 55 01...
  • Page 4: Table Of Contents

    Pneumatic Auto Retract System Near-Infrared Borescope Contents Introduction Safety Instructions System Overview System Components Component Checklist NIR-B Camera Media Bar Air Filter Unit Remote Control Unit Media Cabinet Retraction Device Spares & Accessories System Service Requirements Electrical Power Supply Air Supply Water Supply Operating Temperature Limits.
  • Page 5: Introduction

    INTRODUCTION...
  • Page 6 Fig. 1-1 Pneumatic Auto Retract System for NIR-B Borescope Fig. 1-2 Pneumatic Auto Retract System typical Furnace Installation...
  • Page 7: Safety Instructions

    Also, make sure that all the work described in this guide is completed before AMETEK Land / SVA supervise the installation of the retraction device and camera. If you are in any doubt about anything described in this guide, contact AMETEK Land for further information.
  • Page 8 Pneumatic Auto Retract System Near-Infrared Borescope 1 - 2 Pre-Installation Guide...
  • Page 9 Near-Infrared Borescope Pneumatic Auto Retract System Pre-Installation Guide 1 - 3...
  • Page 10: System Components

    SYSTEM COMPONENTS...
  • Page 11: Component Checklist

    NIR-B-Glass-90-18-3-25-PAR - Model Nº 812144 Refer to the tables on the following pages. Check that you have been supplied with all the components listed. If any components are missing or damaged, contact AMETEK Land immediately. Component Present (Tick box) Furnace Mounting Assembly...
  • Page 12 Pneumatic Auto Retract System Near-Infrared Borescope Component Present (Tick box) Furnace Seal Assembly Media Bar Air Filter Unit Air Filter Cartridge Set Remote Control Unit Media Cabinet Camera Cables (1 x 25 m Power Cable, 1 x 25 m Ethernet Cable) 25m Silicone Cable (Remote Control Unit to Media Cabinet) PTFE Hose Set...
  • Page 13: Nir-B Camera

    Near-Infrared Borescope Pneumatic Auto Retract System WARNING The Auto Retract System contains moving parts. When choosing an installation location make sure that there is sufficient room for the system to move freely along the entire length of the Pneumatic Slide - especially when the System is retracted fully. Refer to the Installation Diagrams (Section 4 of this Guide).
  • Page 14: Retraction Device

    • Hanger Assembly; • NIR-B Camera Housing; The Retraction Device must be installed under the supervision of AMETEK Land Personnel. 2.8 Spares & Accessories The following table gives a list of spare parts and accessories available from AMETEK Land / SVA.
  • Page 15: System Service Requirements

    SYSTEM SERVICE REQUIREMENTS...
  • Page 16 Pneumatic Auto Retract System Near-Infrared Borescope Fig. 3-1 Media Cabinet Dimensions and Air/Water Inlet/Outlets...
  • Page 17: Electrical Power Supply

    Media Cabinet to the Media Bar must be provided by the customer. Rigid, steel pipe and fittings must be used. AMETEK Land/ SVA supply flexible PTFE hoses to connect the Media Bar to the Retraction System. Refer to Fig. 3-2 (overleaf) for an overview of the customer-supplied components.
  • Page 18: Water Supply

    Pneumatic Auto Retract System Near-Infrared Borescope 3.3 Water Supply (Continued) • Water quality: • Carbonate hardness: Maximum 0.712 mmol/l (2 ºdH) • Without carbonate hardness: Maximum 1.785 mmol/l (5 ºdH) • Suspended solids: Maximum 10 mg/l • Free CO Maximum 0 mg/l •...
  • Page 19 Near-Infrared Borescope Pneumatic Auto Retract System Pre-Installation Guide 3 - 3...
  • Page 20 Pneumatic Auto Retract System Near-Infrared Borescope 3 - 4 Pre-Installation Guide...
  • Page 21: Installation Drawings

    INSTALLATION DRAWINGS...
  • Page 22 Pneumatic Auto Retract System Near-Infrared Borescope 4 - 0 Pre-Installation Guide...
  • Page 23 Near-Infrared Borescope Pneumatic Auto Retract System Fig. 4-2 Auto Retract System - Furnace Installation Dimensions (1 of 3) Pre-Installation Guide 4 - 1...
  • Page 24 Pneumatic Auto Retract System Near-Infrared Borescope Fig. 4-3 Auto Retract System - Furnace Installation Dimensions (2 of 3) 4 - 2 Pre-Installation Guide...
  • Page 25 Near-Infrared Borescope Pneumatic Auto Retract System Total weight 63 kg Fig. 4-4 Auto Retract System - Furnace Installation Dimensions (3 of 3) Pre-Installation Guide 4 - 3...
  • Page 26 Pneumatic Auto Retract System Near-Infrared Borescope 4 - 4 Pre-Installation Guide...
  • Page 27 Near-Infrared Borescope Pneumatic Auto Retract System Pre-Installation Guide 4 - 5...
  • Page 28 Pneumatic Auto Retract System Near-Infrared Borescope Fig. 4-7 Media Cabinet Dimensions and Air/Water Inlet/Outlets 4 - 6 Pre-Installation Guide...
  • Page 29 Near-Infrared Borescope Pneumatic Auto Retract System Pre-Installation Guide 4 - 7...
  • Page 30 Pneumatic Auto Retract System Near-Infrared Borescope Fig. 4-9 Air Filter Unit Dimensions Fig. 4-10 Remote Control Unit Dimensions 4 - 8 Pre-Installation Guide...
  • Page 31 AMETEK Land/SVA. The NIR-B Camera is covered by 36 Months Warranty. NOTE: If the system is not commissioned by AMETEK Land/SVA, then there is a risk of damage to the equipment which will not be covered by any warranty.
  • Page 32 NIR-B HIGH PRECISION RADIOMETRIC THERMAL IMAGING IN FURNACES AMETEK Land China Service AMETEK Land India Service Land Instruments International AMETEK Land - Americas Part A, 1st Floor No. 460 Divyasree N R Enclave,Block A, Dronfield, S18 1DJ, 150 Freeport Road, Pittsburgh,...

This manual is also suitable for:

Nir-b-glass-90-18-3-25-par812144