  • Page 1 Thermoregulator (Water Type) User Manual...
  • Page 2 Follow us on social media! www.instagram.com/ekinendustriyel www.facebook.com/ekinendustriyel www.youtube.com/ekinendustriyel www.linkedin.com/company/ekinendustriyel www.twitter.com/ekinendustriyel www.soundcloud.com/ekinendustriyel www.spotify.com/ekin endustriyel...
  • Page 3 The journey of innovation has started with a question for us too: “How can we develop value-added technologies in Turkey?”. First turning point in this long journey was the birth of MIT (Made in Turkey) brand. MIT made us the first plate heat exchanger producer of Turkey and it’s founding vision was not to become a local alternative, it was to build a high-quality brand that can compete on a global level.
  • Page 4 HEAT TRANSFER PRODUCTS • Gasketed Plate Heat Exchangers • Brazed Heat Exchangers • Shell & Tube Heat Exchangers • Evaporators and Condensers • DC Fan Driven Oil Coolers • Heat Coils • Serpentines / Radiators / Economizers PRESSURE VESSELS • Water Heater Tanks •...
  • Page 5: Table Of Contents

    Contents Instruction Manual ............................1 Working Principle ............................2 Controller ................................3 Menu Entry ............................4 First Start-Up ............................4 Power Connection ..........................6 Mold And Water Connections ......................7 Y Type Water Filter ..........................8...
  • Page 6: Instruction Manual

    All service operations must be carried out by trained personnel without exception. This manual contains all the instructions required for operating and maintenance. MIT-TRG-S series are mostly used in heating and stabilizing the molds of injection molding machines. They are also suitable to use in similar systems.
  • Page 7: Working Principle

    After making the cooling tower connections of the cooling inlet of the mold heater, open all the valves. 3. Turn on the main switch and the low-level lamp will light up with an audible alarm. The MIT- TRG-S series automatically fills up water until this alarm stops.
  • Page 8: Controller

    CONTROLLER MIT-TRG-S Series 6-9-12-24-36 Kw Name Function Instructions After connecting the three Be careful during installation since Power Light phases, it will light green when electrical parts and cable terminals have the main switch is turned on. electrical current. Phases are connected reverse Reverse Phase or there is a short circuit.
  • Page 9: Menu Entry

    MENU ENTRY Power ON MENU Password confirm Monitor Screen Monitor screen 1 Monitor screen 2 Monitor screen MENU MENU Contrast adjust the screen MENU 2 Alarm 4 Temperature 1 Control 3 Output MENU MENU MENU MENU 1- PB 1- Phase Alarm 1- Output Mode 1- H.
  • Page 10 MIT-TRG-S Series Mold Heater can be adjusted up to a maximum temperature of 120 °C. 5. The device automatically adjusts the mold temperature with an accuracy of ± 1 °C WARNING: Check the direction of rotation of the pump. INFORMATION: In order for the device to function continuously without malfunctions and to have a long life, it should be operated within the parameters stated in this manual.
  • Page 11: Power Connection

    Power Connection...
  • Page 12: Mold And Water Connections

    Mold and Water Connections Water Outlet Water Inlet Figure 1 Figure 2 Mold connection pipes are installed in the inlet-outlet pipes on the device as shown in Figure 1. Then the other ends of the hoses are attached to the mold. After that valves behind the device are opened and hose connections are completed for the first start-up.
  • Page 13: Y Type Water Filter

    Y Type Water Filter 1. Cooling water used in the system should be soft and clean. Filter collects the sediment and other particles in the water passing through the pipes to prevent possible damage to the device. 2. Dirty and clogged filter prevents the device from working properly and the temperature rises above the optimal value.
  • Page 14 General Maintenance Date: ../../.... Date: ../../.... Date: ../../.... Check operating functions. Check operating functions. Check operating functions. Check all electrical connections. Check all electrical connections. Check all electrical connections. Check all electrical cables. Check all electrical cables. Check all electrical cables.
  • Page 16 CERTIFICATES...
  • Page 18 PROFESSIONAL SYSTEM SOLUTION CENTER From our MIT professional system solution center, you can get help with problems with your pumps, heat exchangers and your system. Our solution center consisting of our expert engineers will be happy to help you. • Domestic hot water installations.
  • Page 19 Today; 135 points in the world.
  • Page 20 3 5 4 6 Dudullu Organize Sanayi Bölgesi - Des Sanayi Sitesi 107. Sk. B14 Blok No: 2 Ümraniye / İstanbul / Turkey Phone: +90 216 232 24 12 Fax: +90 216 660 13 08 info@ekinendustriyel.com - www.ekinendustriyel.com...

This manual is also suitable for:

Trg-s-9Trg-s-12Trg-s-24Trg-s-36Trg-bs-6Trg-bs-12