Case-to-case, refrigerated service to refrigerated service case adjoinment, ambient service to refrigerated service case adjoinment, refrigerated or ambient service to refrigerated or ambient self-service adjoinment, ambient service to ambient service cas
Do you have a question about the Reveal and is the answer not in the manual?
Questions and answers
Subscribe to Our Youtube Channel
Summary of Contents for Structural Concepts Reveal
Page 1
Refrigerated or Ambient Service To Refrigerated or Ambient Self-Service Adjoinment Ambient Service To Ambient Service Case Adjoinment P/N 21-08289 888 E. Porter Road ∙ Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com Operating Manuals\Specialty\Reveal Case Adjoinment Guide_21-08289.pub Rev A Date: 6.12.2019...
Table of Contents Refrigerated Service To Refrigerated Service Case Adjoinment Section .………………. Refrigerated Service To Refrigerated Service Case Adjoinment Kit Information ..…..… Refrigerated Service To Refrigerated Service Case Adjoinment Guide ..………………... 5-13 Ambient Service To Refrigerated Service Case Adjoinment Section .……...……………. Ambient Service To Refrigerated Service Case Adjoinment Kit Information ...………..
Corporation’s Reveal® Refrigerated Service to Refrigerated Service Merchandisers only. >> Adjoinment Kit: Structural Concepts Kit #20-92359SS contains all of the components as part of this adjoinment process. The list of parts is listed below. If list is included in kit box, it supersedes this list.
Refrigerated Service To Refrigerated Service Case Adjoinment Guide >> Case Adjoinment Process: 1. Before adjoining case, apply a CONTINUOUS bead of SCC supplied silicone sealant at center of Caution! Before beginning adjoinment process, glass edge, on uprights, and on sides of case. Note: make sure case is not connect to any power Sealant is represented by dashed lines for illustrative source.
Page 6
Refrigerated Service To Refrigerated Service Case Adjoinment Guide, Continued >> Case Adjoinment Process: 2 Remove screws at upright’s upper raceway covers. 3. Remove screws at upright’s lower raceway covers. >> Adjoinment instructions continue on next page. Note: Illustrations Shown May Not Reflect Every Feature Or Option Of Your Particular Case.
Page 7
Refrigerated Service To Refrigerated Service Case Adjoinment Guide, Continued >> Case Adjoinment Process, Continued: 4. Remove rear-left raceway covers from case. 5. Remove rear-right raceway covers from case. >> Adjoinment instructions continue on next page. Note: Illustrations Shown May Not Reflect Every Feature Or Option Of Your Particular Case.
Page 8
Refrigerated Service To Refrigerated Service Case Adjoinment Guide, Continued >> Case Adjoinment Process, Continued: 6. Use SCC-supplied screws, washers and nuts to adjoin case at upper uprights. 7. Use SCC-supplied screws, washers and nuts to adjoin case at lower uprights. >>...
Page 9
Refrigerated Service To Refrigerated Service Case Adjoinment Guide, Continued >> Case Adjoinment Process, Continued: 8. Reattach rear-left raceway cover to case (see step #2 in this guide for attachment locations). 9. Reattach rear-right raceway covers to case (see step #3 in this guide for attachment locations). >>...
Page 10
Refrigerated Service To Refrigerated Service Case Adjoinment Guide, Continued >> Case Adjoinment Process, Continued: 10. Use SCC-supplied screws, washers and nuts to adjoin upper glass support brackets. 11. Use SCC-supplied screws, washers and nuts to adjoin lower glass support brackets. >>...
Page 11
Refrigerated Service To Refrigerated Service Case Adjoinment Guide, Continued >> Case Adjoinment Process, Continued: 12. Use SCC-supplied screws, washers and nuts to adjoin case at front-lower base area. 13. Use SCC-supplied screws, washers and nuts to adjoin case at rear-lower base area. >>...
Page 12
Refrigerated Service To Refrigerated Service Case Adjoinment Guide, Continued >> Case Adjoinment Process, Continued: Note: Proper silicone sealant helps to maintain proper case temperature by preventing warm air from entering case (or cool air from exiting case). Carefully follow these instructions! 14.
Page 13
Refrigerated Service To Refrigerated Service Case Adjoinment Guide, Continued >> Case Adjoinment Process, Continued: place atop (horizontal) and against (vertical) UV-bonded glass adjoinment areas and secure in Note: Proper silicone sealant helps to maintain place with tape. Allow time for curing. Remove proper case temperature by preventing warm air tape after trim has cured.
Corporation’s Reveal® Ambient Service to Refrigerated Service Merchandisers only. >> Adjoinment Kit: Structural Concepts Kit #20-92359SS contains all of the components as part of this adjoinment process. The list of parts is listed below. If list is included in kit box, it supersedes this list.
Ambient Service To Refrigerated Service Case Adjoinment Guide >> Case Adjoinment Process: 1. Remove screws at upright’s upper raceway covers. Note: Illustrations Shown May Not 2. Remove screws at upright’s lower raceway covers. Reflect Every Feature Or Option Of Your Particular Case. >>...
Page 17
Ambient Service To Refrigerated Service Case Adjoinment Guide, Continued >> Case Adjoinment Process, Continued: 3. Remove rear-left raceway cover from case. Note: Illustrations Shown May Not 4. Remove rear-right raceway cover from case. Reflect Every Feature Or Option >> Adjoinment instructions continue on next page. Of Your Particular Case.
Page 18
Ambient Service To Refrigerated Service Case Adjoinment Guide, Continued >> Case Adjoinment Process, Continued: 5. Use SCC-supplied screw, washer and nut to adjoin case at upper upright. 6. Use SCC-supplied screw, washer and nut to adjoin case at lower upright. >>...
Page 19
Ambient Service To Refrigerated Service Case Adjoinment Guide, Continued >> Case Adjoinment Process, Continued: 7. Reattach rear-left raceway cover to case (see step #2 in this guide for attachment locations). 8. Reattach rear-right raceway covers to case (see step #3 in this guide for attachment locations). >>...
Page 20
Ambient Service To Refrigerated Service Case Adjoinment Guide, Continued >> Case Adjoinment Process, Continued: 9. Use SCC-supplied screw, washer and nut to adjoin case at front-lower base area. 10. Use SCC-supplied screw, washer and nut to adjoin case at rear-lower base area. >>...
Page 21
Ambient Service To Refrigerated Service Case Adjoinment Guide, Continued >> Case Adjoinment Process, Continued: Note: Proper silicone sealant helps to maintain proper case temperature by preventing warm air from entering case (or cool air from exiting case). Carefully follow these instructions! 11.
Page 22
Ambient Service To Refrigerated Service Case Adjoinment Guide, Continued >> Case Adjoinment Process, Continued: 13. Apply TWO beads of SCC-supplied silicone sealant to underside of trim covers. Carefully Note: Proper silicone sealant helps to maintain place atop (horizontal) and against (vertical) proper case temperature by preventing warm air UV-bonded glass adjoinment areas and secure in from entering case (or cool air from exiting case).
Refrig. or Ambient Service To Refrig. or Ambient Self-Service Case Adjoinment Section REFRIGERATED OR AMBIENT SERVICE REFRIGERATED OR AMBIENT SELF-SERVICE CASE ADJOINMENT SECTION...
Corporation’s Reveal® Refrigerated or Ambient Service to Refrigerated or Ambient Self-Service Merchandisers only. >> Adjoinment Kit: Structural Concepts Kit #21-09193 contains all of the components as part of this adjoinment process. The list of parts is listed below. If list is included in kit box, it supersedes this list.
Page 25
Refrig. or Ambient Service To Refrig. or Ambient Self-Service Case Adjoinment Guide >> Case Adjoinment Process: 1. Before adjoining case, apply a CONTINUOUS bead of SCC supplied silicone sealant on uprights Caution! Before beginning adjoinment process, and sides of case. Note: Sealant is represented by make sure case is not connect to any power dashed lines for illustrative purposes only.
Page 26
Refrig. or Ambient Service To Refrig. or Ambient Self-Service Case Adjoinment Guide, Cont’d >> Case Adjoinment Process, Continued: 2. Disconnect LED lights from its plugs. Remove shelves from case (by lifting up and off). Place in secure location away from foot traffic. 3.
Page 27
Refrig. or Ambient Service To Refrig. or Ambient Self-Service Case Adjoinment Guide, Cont’d >> Case Adjoinment Process, Continued: 7. Remove screws securing rear plenum to case. Remove rear plenum from case. Place in secure 4. Remove screw at upright’s upper raceway cover. location away from foot traffic.
Page 28
Refrig. or Ambient Service To Refrig. or Ambient Self-Service Case Adjoinment Guide, Cont’d >> Case Adjoinment Process, Continued: 9. Adjoin service case to self-service case by inserting SCC-supplied screws, washers and nuts at adjoinment 8. Remove service case’s raceway cover location obrounds along uprights.
Page 29
Refrig. or Ambient Service To Refrig. or Ambient Self-Service Case Adjoinment Guide, Cont’d >> Case Adjoinment Process, Continued: 11. Replace service case’s raceway cover. Attachment Note: Illustrations Shown May Not instructions are shown on the next page. Reflect Every Feature Or Option Of Your Particular Case.
Page 30
Refrig. or Ambient Service To Refrig. or Ambient Self-Service Case Adjoinment Guide, Cont’d >> Case Adjoinment Process, Continued: 14. Refrigerated cases only: Reach through rear plenum opening, grasp temperature probe cover and 12. Reattach upright’s upper raceway cover with pull through opening. Reattach to rear plenum with screws that had been removed at earlier step.
Page 31
Refrig. or Ambient Service To Refrig. or Ambient Self-Service Case Adjoinment Guide, Cont’d >> Case Adjoinment Process, Continued: 16. Apply a CONTINUOUS bead of SCC-supplied silicone sealant to seal along upper case adjoinment Note: Proper silicone sealant helps to maintain seam (horizontally).
Page 32
Refrig. or Ambient Service To Refrig. or Ambient Self-Service Case Adjoinment Guide, Cont’d >> Case Adjoinment Process, Continued: 20. Replace decks (by carefully setting in place over tub area. 19. Replace shelves from case (by carefully inserting shelving bracket hooks into upright slots. >>...
Page 33
Refrig. or Ambient Service To Refrig. or Ambient Self-Service Case Adjoinment Guide, Cont’d >> Case Adjoinment Process, Continued: 20. Use SCC-supplied screw, washer and nut to adjoin case at front-lower base area. 22. Use SCC-supplied screw, washer and nut to adjoin case at rear-lower base area. >>...
Corporation’s Reveal® Ambient Service to Ambient Service Merchandisers only. >> Adjoinment Kit: Structural Concepts Kit #20-92359SS contains all of the components as part of this adjoinment process. The list of parts is listed below. If list is included in kit box, it supersedes this list.
Ambient Service To Ambient Service Case Adjoinment Guide >> Case Adjoinment Process: Note: Illustrations Shown May Not 2 Remove screws at upright’s upper raceway covers. Reflect Every Feature Or Option 3. Remove screws at upright’s lower raceway covers. Of Your Particular Case. >>...
Page 37
Ambient Service To Ambient Service Case Adjoinment Guide, Cont’d >> Case Adjoinment Process, Continued: 4. Remove rear-left raceway covers from case. Note: Illustrations Shown May Not 5. Remove rear-right raceway covers from case. Reflect Every Feature Or Option Of Your Particular Case. >>...
Page 38
Ambient Service To Ambient Service Case Adjoinment Guide, Cont’d >> Case Adjoinment Process, Continued: 6. Use SCC-supplied screws, washers and nuts to adjoin case at upper uprights. 7. Use SCC-supplied screws, washers and nuts to adjoin case at lower uprights. >>...
Page 39
Ambient Service To Ambient Service Case Adjoinment Guide, Cont’d >> Case Adjoinment Process, Continued: 8. Remove rear-left raceway covers from case. Note: Illustrations Shown May Not 9. Remove rear-right raceway covers from case. Reflect Every Feature Or Option Of Your Particular Case. >>...
Page 40
Ambient Service To Ambient Service Case Adjoinment Guide, Cont’d >> Case Adjoinment Process, Continued: Note: Illustrations Shown May Not 10. Use SCC-supplied screws, washers and nuts to adjoin Reflect Every Feature Or Option case at front-lower base area. Of Your Particular Case. 11.
Page 41
Ambient Service To Ambient Service Case Adjoinment Guide, Cont’d >> Case Adjoinment Process, Continued: 12. Apply a CONTINUOUS bead of SCC supplied silicone sealant along UV-bonded glass adjoinment points. Note: Sealant is represented by dashed lines for illustrative purposes only. >>...
Page 42
Ambient Service To Ambient Service Case Adjoinment Guide, Cont’d >> Case Adjoinment Process, Continued: place with tape. Allow time for curing. Remove tape after trim has cured. Note: Sealant is If trim is supplied with your adjoinment kit, follow represented by dashed lines for illustrative these instructions.