Advertisement

ENERGY AND INFORMATION DEVICE
USER MANUAL
TRIOMED COMPACT
Version 4
Introduced on 20.03.2015
Tallinn 2015

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the COMPACT and is the answer not in the manual?

Questions and answers

Summary of Contents for Triomed COMPACT

  • Page 1 ENERGY AND INFORMATION DEVICE USER MANUAL TRIOMED COMPACT Version 4 Introduced on 20.03.2015 Tallinn 2015...
  • Page 2 Address: Maealuse 4, EE-12618 Tallinn, Estonia Telephone: +(372)56888978 E-mail: triomed-eu.eu Triomed EU OU (Ltd) does hereby declare that we are solely responsi- ble for the following product: Energy and information device “TRIOMED COMPACT“ (with inte- grated emitters, options: 40-43 GHz)
  • Page 3 TRIOMED COMPACT. USER MANUAL Dear Consumer! This manual on how to use the TRIOMED COMPACT device 2274 is meant for users and medical staff. The device is supplied ready for use and can be implemented only for its intended purpose in strict compliance with the operation instruc- tions, safety measures and rules of therapeutic application.
  • Page 4 TRIOMED COMPACT. USER MANUAL THE FOLLOWING SIGNS HAVE BEEN USED IN THE MANUAL AND FOR LABELLING THE DEVICE: 2274 CE labelling Consult instructions for use Non-ionising electromagnetic Fragile, radiation handle with care! Caution, consult Device serial number accompanying documents Not for general...
  • Page 5: Table Of Contents

    TABLE OF CONTENTS 1. PURPOSE 2. MECHANISMS OF THERAPEUTIC EFFECTS 2.1. General mechanisms of action 2.2. Mechanisms of specialised action of MM radiation 3. INDICATIONS AND CONTRAINDICATIONS FOR USE 3.1. Indications 3.2. Contraindications for using MM radiation: 4. TECHNICAL AND OPERATIONAL CHARACTERISTICS 4.1.
  • Page 6: Purpose

    TRIOMED COMPACT. USER MANUAL 1. PURPOSE The TRIOMED COMPACT device has been designed for maintaining and strengthening the health of the elderly as well as for treating and preventing various pathological conditions by stimulating the skin with low intensity (up to 10 μW/cm...
  • Page 7 TRIOMED COMPACT. USER MANUAL functions, restore (optimise) physical capacity, increase the functional reserves of the body and improve the quality of life in medical terms. MM therapy can be used in compre- hensive programmes at early and later states of restorative treatment of diseases and injuries, during rehabilitation and in the case of chronic diseases during a non-acute period.
  • Page 8: Mechanisms Of Therapeutic Effects

    TRIOMED COMPACT. USER MANUAL 2. MECHANISMS OF THERAPEUTIC EFFECTS 2.1. General mechanisms of action Electromagnetic waves in the millimeter (MM) range have a low capacity to penetrate biological tissues (0,2-0,6 mm), are almost fully absorbed by the upper layers of the skin and by the water, hydrated proteins and collagen fibres con- tained in them and do not have a thermal effect.
  • Page 9: Mechanisms Of Specialised Action Of Mm Radiation

    TRIOMED COMPACT. USER MANUAL IR radiation is absorbed by acceptor molecules and cel- lular membranes. The mechanisms of impact of IR radiation on biological tissues comprise the totality of molecular and cellular ef- fects including the local activation of energy-binding proc-...
  • Page 10 TRIOMED COMPACT. USER MANUAL demonstrate a great harmonising potential and biological effect and at the same time have a lower mean power. Each therapeutic programme uses several low-frequen- cy modulations which have a positive directed impact on the cells of various organs as well as on blood and lymphatic...
  • Page 11: Indications And Contraindications For Use

    TRIOMED COMPACT. USER MANUAL 3. INDICATIONS AND CONTRAINDICATIONS FOR USE MM therapy can be used in prevention programmes, in comprehensive treatment of acute diseases and exacerba- tions of chronic illnesses as well as in restorative treatment (rehabilitation) programmes, including follow-up treatment.
  • Page 12 TRIOMED COMPACT. USER MANUAL I-II degree arterial hypertension: to lower high arterial • blood pressure by adjusting sympathetic-adrenal and parasympathetic influences on the regulation of the heart function, improve the overall health; • organic diseases of the central nervous system (is-...
  • Page 13 TRIOMED COMPACT. USER MANUAL • chronic inflammatory diseases of the respiratory tract (chronic bronchitis, chronic obstructive pulmonary disease, asthma): to improve bronchial permeability, normalise metabolic activity, stabilise the membranes of phagocyteised neutrophils, lower the intensity of per- oxidation of lipids, lower the non-specific hyperactivity of the bronchi, improve the functions of external respi- ration, activate the discharge of bronchial mucus, reduce the frequency of coughing fits;...
  • Page 14 TRIOMED COMPACT. USER MANUAL • chronic prostatitis: to relieve pain, reduce inflammation, normalise urination, restore erection and copulative function, alleviate psychoemotional problems; • light depression: for mild sedative and anti-stress ef- fect, to lower irritability and psycho-emotional distress, to correct sleep disorders and raise spirits;...
  • Page 15: Contraindications For Using Mm Radiation

    TRIOMED COMPACT. USER MANUAL 3.2. Contraindications for using MM radiation: • general contraindications to physical therapy; • unknown diagnosis; • idiosyncrasy to electromagnetic millimeter stimulation; • febrile states of unclear aetiology; • patients having an implanted device with autonomous power supply (in the area of the device installation). Contraindications for using IR radiation: • benign or malignant neoplasms, • active forms of tuberculosis, • III-degree hypertension, bleeding and II-III...
  • Page 16: Technical And Operational Characteristics

    CHARACTERISTICS 4.1. General technical characteristics The device is produced without using any harmful chemi- cal substances in compliance with the TRIOMED EU Ltd tech- nical documents and meets the requirements of Directives 93/42/EEC and 2007/47/EC. As far as potential risks of use are concerned, the device...
  • Page 17 1-8 correspond- ing to the programmes numbered 31-38 in accordance with the unified register of the manufacturer. The main technical characteristics of the TRIOMED COMPACT device are given in Table 1 below. Table 1 No Characteristics Description Start–up time...
  • Page 18: Structure And Functioning

    TRIOMED COMPACT. USER MANUAL Millimeter electromagnetic radiation is modulated by a simple low-frequency or complexly modulated signal. The frequency, duration and form of modulating signals are changed during the treatment session according to original programmes labelled by identification numbers. The mod-...
  • Page 19 TRIOMED COMPACT. USER MANUAL Figure 1. General view 1 – light indicators 2 – control button 3 – hanging loop 4 – battery holder 5 – strap fastening 6 – speaker Figure 2. Bottom panel 1 – IR radiator 2 – location of the MM EMR generator 3 –...
  • Page 20: Use Of The Device

    TRIOMED COMPACT. USER MANUAL To confirm that the device is working in accordance with the programme selected, the corresponding LEDs (fig 3-10) are switched on and a sound signal is produced briefly at certain intervals (3-4 sec). To use the device without sound, enter again the pro- gramme selection mode by pressing and holding the con- trol button.
  • Page 21 TRIOMED COMPACT. USER MANUAL If you want to use the programme that was running dur- ing the previous session, switch on the device by briefly pressing the control button. The LED indication of the programmes in the selection and operation modes is shown in Fig. 3-10.
  • Page 22: Package Contents

    TRIOMED COMPACT. USER MANUAL 5. PACKAGE CONTENTS Package contents: • TRIOMED COMPACT device; • CR2032 battery installed; • user manual; • consumer packaging; • warranty. 6. LABELLING The marking is shown on the label placed at the bottom of the device. The label (Fig. 11) specifies: • name and model of the...
  • Page 23: Packaging

    TRIOMED COMPACT. USER MANUAL 7. PACKAGING The packaging protects the device from weather and mechanical damage. The packaging (box) provides all the required information in English and the language of the sell- er’s country about the product, package contents, manufac- turer.
  • Page 24: Preparing The Device For Use

    TRIOMED COMPACT. USER MANUAL 10. PREPARING THE DEVICE FOR USE 10.1. Operating restrictions The device can be used only after reading the User Manual. IT IS FORBIDDEN: • to use the device without reading the User Manual; • to use the faulty or damaged device; • to use the device in rooms with high humidity; • to put the device into water; • to let water and chemical substances get in- side the device;...
  • Page 25: Safety Precautions

    TRIOMED COMPACT. USER MANUAL 10.2. Safety precautions • no special safety precautions are required for the patient in the case of device fail- ure, emergency or urgent evacuation of the medical staff; • the patient can assume any comfortable posi- tion during the treatment with the device.
  • Page 26: List Of Possible Faults And Suggested Remedies

    TRIOMED COMPACT. USER MANUAL • insert a new CR2032 battery into the battery holder observing the polarity; • reinstall the top panel and fasten it to the bottom panel with the screws. The level of the battery charge is indicated by the bright- ness of the LEDs. The serviceability of the device should be checked before every use. The normal functioning of the device is described in Section 4.2 “Structure and functioning”.
  • Page 27: Technical Maintenance

    TRIOMED COMPACT. USER MANUAL The device does not Electric Send the device to be exit the selection mode circuit failure repaired and does not switch off mute mode Electric Send the device to be cannot be selected circuit failure repaired...
  • Page 28: Procedure For Using The Device

    This User Manual regulates the therapeutic use of the device. By exposing areas of the skin to a MM electromagnetic field using the TRIOMED COMPACT device, you can exert a positive effect on the internal organs and vital functions of the organism.
  • Page 29: Programme Description

    TRIOMED COMPACT. USER MANUAL 11.1. Programme description Programme no. 1 Harmony (30 minutes). Distant stimulation. It is used as the main mode: • to prevent acute conditions and exacer- bations of chronic diseases; • to reduce the risk of complications in the case of acute and chronic diseases by ac-...
  • Page 30 TRIOMED COMPACT. USER MANUAL Programme no. 2 Universal (10 minutes) is designed to prevent the occurrence of acute conditions and exacerbations of chronic illnesses by improving the func- tion of the autonomic nervous and im- mune systems and optimising the re- sponse of the body.
  • Page 31 TRIOMED COMPACT. USER MANUAL This programme is recommended for local stimulation in the pathological focus or in painful areas of the projection of the organs in the Head’s zones. The duration of stimulation of one zone is 15 minutes 1-2 times per day.
  • Page 32 TRIOMED COMPACT. USER MANUAL artery in the area of the wrist (I), the tragus area (II) and (III) the centre of the left palm (in slow circular motions). The duration of stimulation of one zone is 12 minutes once a day. The course of treatment consists of 10 sessions.
  • Page 33 TRIOMED COMPACT. USER MANUAL Programme no. 6 Edelweiss (12 minutes) has an antihypoxic and antioxidant ef- fect. This mode enhances the resistance to hemic, circulatory and tissue hypoxia. The programme improves microcircula- tion and tissue respiration and normalises the functioning of the respiratory chain...
  • Page 34 TRIOMED COMPACT. USER MANUAL from overfatigue). It is recommended for acute and chronic diseases accompanied by intoxication and disturbed micro- circulation or exacerbated by respiratory failure or circulatory deficiency. To activate antihypoxic and antioxi- dant effects it is recommended to use programme no.6 in the zone at the...
  • Page 35 TRIOMED COMPACT. USER MANUAL Programme no. 7 Youth (12 minutes) is used in the case of disturbed metabolism and to slow down aging. This mode restores the nourishment of the tissues and normal- ises the metabolism. The programme helps restore cells and tissues, increase the sensi-...
  • Page 36 TRIOMED COMPACT. USER MANUAL Programme no. 8 Photon (5 minutes) – low-intensity IR stimulation allows to opti- mise the energy supply to the cells, normal- ise the system of intracellular regulation and intensify biosynthetic processes. It fa- cilitates resonant absorption of energy by...
  • Page 37: Selecting The Impact Position

    The course of treatment consists of 10 sessions. 11.2. Selecting the impact position In accordance with the rules and principles of physical ther- apy and restorative medicine (rehabilitation), the TRIOMED COMPACT device can be used to stimulate the following areas: • the pathological focus or the area of its projection, • the projection of the organs in the Head’s zones, • areas of biologically active points and zones...
  • Page 38: Use Of Device In Head Zones

    TRIOMED COMPACT. USER MANUAL effect which builds up in the next 2-3 weeks after a course of stimulation. That is why a pause of 2 to 6 weeks (depend- ing on the patient’s state of health) is necessary between the courses. If necessary courses can be repeated.
  • Page 39 TRIOMED COMPACT. USER MANUAL The majority of therapeutic effects on the damaged inter- nal organs are achieved through the Head’s zones. The figure shows the zones of increased skin sensitivity (hyperesthesia) which are called the Head’s projection zones. In these areas of the skin, any normally painless irrita- tion in the form of pressure, touch, heat or cold causes pain or discomfort.
  • Page 40: Stimulation Of Biologically Active Zones

    TRIOMED COMPACT. USER MANUAL which the affected organs send their signals of distress. Such points are easy to locate. When stimulated, they become sensitive, and even cause pain. Hypersensitivity disappears after the functioning of the organ or system of organs has been normalised.
  • Page 41 TRIOMED COMPACT. USER MANUAL Stimulation should be car- ried out at the level of the 4th cervical vertebra and the 3rd thoracic vertebra (C4-T3) paravertebrally covering the zone of the shoulder girdle top-down in slow rectilin- ear, zig-zag and longitudi-...
  • Page 42 TRIOMED COMPACT. USER MANUAL by staying longer on the most painful spots. The course of treatment comprises 10-15 sessions: 2-3 session a day. Stimulation of the lumbosacral area improves the blood circulation and the trophism of the tissues in the zone of stimulation, in the lower extremities as well as in the pelvic organs.
  • Page 43: Stimulation Of Reflexogenic Zones

    TRIOMED COMPACT. USER MANUAL and the internal genitourinary organs. Stimulation of the anterior abdominal wall allows to influence actively the state of these organs. The radiator should be slowly moved in the lower part of the abdominal wall in alternating rectilinear, circular and zigzag motions.
  • Page 44 TRIOMED COMPACT. USER MANUAL session, the control button needs to be pressed. When the device is working normally, the LEDs are periodically switched on in the combination that corresponds to the programme selected; the speaker produces sound. • The duration of the stimulation is determined by the programme.