Water inlet & outlet adaptor Handle Switch Socket Tank (with evaporator) Base Compressor Fan motor Condenser Water temperature sensor Filter (front cover) Front cover PERFORMANCE CURVE THE REFRIGERATION PERFORMANCE TEST IS INDICATED WHEN THE AMBIENT TEMPERATURE IS 86°F 1/10 HP www.hydrotek.ca...
13 - 50 GAL (50-190 L) Weight 34 lbs Size 16.5 " x 10 " x 14.5 " * The BTU is measured at an ambient temperature of 97°F (36°C) and the Chiller is working at 1100W/9.6A power. Recommended Pump: 160 or 250 GPH www.hydrotek.ca...
Page 4
Front trim cover Circuit board Back cover of circuit board Seal sleeve Condenser Back cover Handle Compressor Base Tank (with evaporator) Top cover PERFORMANCE CURVE THE REFRIGERATION PERFORMANCE TEST IS INDICATED WHEN THE AMBIENT TEMPERATURE IS 86°F 1/4 HP www.hydrotek.ca...
Page 5
52 GAL to 132 GAL. When reservoir capacity falls, the water temperature will drop faster. * The BTU is measured at an ambient temperature of 97°F (36°C) and the Chiller is working at 1100W/9.6A power. Recommended Pump: 250 or 550 GPH www.hydrotek.ca...
• The compressor protection device system is built to shut off the circuit automatically to prevent the motor from burning out when the motor is overheating • Temperature memory system that allows the chiller to refrigerate continuously according to the previous temperature setting www.hydrotek.ca...
Reset temperature decreased or there is no temperature refrigeration Clean the air inlet/outlet with a brush The air inlet or outlet are clogged or a vacuum cleaner Loud Operation Not installed on a flat surface Reinstall correctly www.hydrotek.ca...
Page 13
2. Plug the chiller into a grounded outlet and ensure the power switch located on the back of the unit is in the “ON” (I) posi on. www.hydrotek.ca...
Page 14
Over me, nutrient deposits and other debris may accumulate inside the chiller, impeding the operability. To prevent clogging and minimize maintenance, we recommend use of our 6" or 10" filter bag with your submersible pump. www.hydrotek.ca...
Page 15
We recommend that the power source support ONLY the chiller unit and no addi onal appliances in order to prevent a power surge or circuit overload. Remote operation of the chiller unit outside of the grow space will reduce the amount • of heat generated within the garden. Warnings: www.hydrotek.ca...
Page 16
"Spare Fuse". STEP 7 STEP 8 STEP 9 "Spare Fuse" "Fuse in Use" Remove "Spare Fuse" from side Insert the "spare fuse" into the Insert fuse cover and push in. "fuse in use" slot. compartment. ® www.hydrotek.ca...