Do you have a question about the 12589-01 and is the answer not in the manual?
Questions and answers
Summary of Contents for L'HOTELLIER 12589-01
Page 1
F9211 4 rue Henri Poincaré 92167 ANTONY CEDEX France Tel No. (33) 01.46.66.08.08 Fax No. (33) 01.46.66.23.24 COMPONENT MAINTENANCE MANUAL WITH ILLUSTRATED PARTS LIST FIRE EXTINGUISHER 12589-01 Initial issue : APR 01/11 Page T-1 26-20-50 APR 01/11 PRINTED IN FRANCE...
Page 2
The document reference is online, please check the correspondence between the online documentation and the printed version.
Page 3
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) RECORD OF REVISIONS REV. REVISION INSERTION REV. REVISION INSERTION N° DATE DATE N° DATE DATE APR 01/11 Page RR-1/RR-2 26-20-50 APR 01/11 PRINTED IN FRANCE The document reference is online, please check the correspondence between the online documentation and the printed version.
Page 4
The document reference is online, please check the correspondence between the online documentation and the printed version.
Page 5
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) RECORD OF TEMPORARY REVISIONS TEMPORARY INSERTED DELETED REVISIONS N° PAGE N° DATE DATE Page RTR-1/RTR-2 26-20-50 APR 01/11 PRINTED IN FRANCE The document reference is online, please check the correspondence between the online documentation and the printed version.
Page 6
The document reference is online, please check the correspondence between the online documentation and the printed version.
Page 7
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) SERVICE BULLETIN LIST SERVICE DATE REV. SUBJECT BULLETIN INSERTED Page SBL-1/SBL-2 26-20-50 APR 01/11 PRINTED IN FRANCE The document reference is online, please check the correspondence between the online documentation and the printed version.
Page 8
The document reference is online, please check the correspondence between the online documentation and the printed version.
Page 9
L’HOTELLIER SERVICE INFORMATION LETTER AIRBUS HELICOPTERS ENGINE/CARGO FIRE EXTINGUISHERS HANDLING SECURITY INSTRUCTIONS A. REASON L’Hotellier receives on a regular basis extinguishers from its customers without safety caps. Extinguishers are pressure vessels. As such, they present a risk of ejection in case of accidental percussion of the burst disc.
Page 10
Fax: +33 1 46 66 66 71 Email : Pierre.deKrassilnikoff@utas.utc.com Mrs Sylvie LA RUFFA Sales Administration Manager L'Hotellier 4 Rue Henri Poincaré, 92167 Antony, FRANCE Tel (Direct line): +33 1 55 59 09 65 Fax: +33 1 46 66 66 71 Email : Sylvie.laruffa@utas.utc.com...
Page 11
10230-00 704A42820043 11536-00 1519324 11683-00 10230-01 704A42820049 10450-00 S262A10A1001 11537-00 1519325 11536-00 1519324 12290-00 S262A10A1003 + 341283-00 (VIS M4x30) 12589-01 M262G00T1002 863487-00 12466-00 13895-00 T262A10T0005 11536-00 1519324 11776-00 1291783 14155-00 704A32820051 14252-00 14253-00 AH FIREX-26-001 REV A SEP 16/15 REF.: SIL AH FIREX-26-001-00-A.DOC Page 3/ 5 The document reference is online, please check the correspondence between the online documentation and the printed version.
Page 13
L’HOTELLIER SERVICE INFORMATION LETTER APPENDIX 3 Secured extinguishers with safety caps Unsecured extinguishers AH FIREX-26-001 REV A SEP 16/15 REF.: SIL AH FIREX-26-001-00-A.DOC Page 5/ 5 The document reference is online, please check the correspondence between the online documentation and the printed version.
Page 14
L’HOTELLIER SERVICE INFORMATION LETTER REVISION TRANSMITTAL SHEET AIRBUS HELICOPTERS ENGINE/CARGO FIRE EXTINGUISHERS HANDLING SECURITY INSTRUCTIONS HISTORIC OF DOCUMENT DATE REASON WRITER APPROBATION 16/09/2015 Origin A. DORNEAU P. de KRASSILNIKOFF REVISION SEQUENCE ORIGIN : SEP 16/15 AH FIREX-26-001 REV A SEP 16/15 REF.: SIL AH FIREX-26-001-00-A.DOC Page TIT The document reference is online, please check the correspondence between the online documentation and the printed version.
Page 15
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) LIST OF EFFECTIVE PAGES SUBJECT PAGE DATE SUBJECT PAGE DATE Title page APR 01/11 Disassembly 3006 APR 01/11 BLANK 3007 APR 01/11 3008 APR 01/11 Record of revisions RR-1 APR 01/11 3009 APR 01/11...
Page 19
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) LIST OF ILLUSTRATIONS Pages DESCRIPTION AND OPERATION Figure 1 – Fire extinguisher 12589-01 (Sheet1) Figure 1 – Fire extinguisher 12589-01 (Sheet2) TEST AND FAULT ISOLATION Figure 1001 – Pressure switch electrical schematic 1003 DISASSEMBLY Figure 3001 –...
Page 20
The document reference is online, please check the correspondence between the online documentation and the printed version.
Page 21
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) LIST OF TABLES Pages DESCRIPTION AND OPERATION Table 1 – Specified Data TESTING AND FAULT ISOLATION Table 1001 – Test Equipment and Materials 1001 Table 1002 – Fault Isolation 1007/1008 DISASSEMBLY Table 3001 – Disassembly Tools, Fixtures and Equipment...
Page 22
The document reference is online, please check the correspondence between the online documentation and the printed version.
Page 23
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) INTRODUCTION TASK 26-20-50-990-801-A01 General This Component Maintenance Manual with Illustrated Parts List meets the requirements of the ATA 100 standard. It should allow an engineer who is not familiar with the unit to inspect and repair it.
Page 24
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) TASK 26-20-50-990-804-A01 Updating Revisions, additions and deletions made manually shall be indicated by the letter "R" in the left margin, solely in front that part of the document which has been modified. TASK 26-20-50-990-805-A01...
Page 25
TASK 26-20-50-870-801-A01 Description General This document describes the Fire Extinguisher (FE) P/N 12589-01 and gives information relating to its maintenance. Detailed Description (Refer to Figure 1) The FE is called "container" in the pages that follow. The container is a DUAL outlet steel sphere.
Page 26
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) D. The disc in the filling and safety relief valve will break when the pressure in the container is more than the usual operating pressure. This will release the extinguishing agent through the safety relief valve and prevent damage to the container from too much pressure.
Page 27
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) Fire Extinguisher 12589-01 Figure 1 (Sheet 1)/GRAPHIC 26-20-50-99B-801-A01 Page 3 26-20-50 APR 01/11 PRINTED IN FRANCE The document reference is online, please check the correspondence between the online documentation and the printed version.
Page 28
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) Fire Extinguisher 12589-01 Figure 1 (sheet 2)/GRAPHIC 26-20-50-99B-801-A01Bis Page 4 26-20-50 APR 01/11 PRINTED IN FRANCE The document reference is online, please check the correspondence between the online documentation and the printed version.
Page 29
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) TASK 26-20-50-870-803-A01 Specification Data The specified data are given in Table 1. Table 1 Specified Data DESCRIPTION OR FONCTION CHARACTERISTICS Operating Pressure 595 to 623,5 psig at +68°F (4100 to 4300 kPa (at +20°C)
Page 30
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) TASK 26-20-50-870-804-A01 Related Publication NFL 63010 Specification. Compressed Gas Association (CGA) Pamphlet C-1. Compressed Gas Association (CGA) Pamphlet C-6. United States Department of Transportation (DOT) Code of Federal Regulations (CFR) 49, Part 173.34. Page 6...
Page 31
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) TESTING AND FAULT ISOLATION TASK 26-20-50-700-801-A01 Testing General This section contains the procedures, materials, and equipment necessary to do the tests of the container and to find the defective parts. Do the visual checks, leak tests and the necessary repairs before you do the electrical and hydrostatic tests.
Page 32
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) Table 1001 Test Equipment and Materials DESCRIPTION PART NUMBER OR SPECIFICATION Platform Scale (Accuracy 0.001 kg) None Digital Indicator (used scale) None Gauge, Thickness, Ultrasonic None Alcohol, Isopropyl None Cloth, Cleaning None Safety test Bench nitrogen...
Page 33
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) (2) Turn the fill plug one full turn counterclockwise. (3) Close the door of the safety proof booth 751776. (4) Open valves C and F (Fig 7001) and adjust the nitrogen supply regulator to get 2000 kPa (5) Open slowly the valve E while you monitor the charging gauge and the multi-meter.
Page 34
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) (6) Bleed completely the pipes. (7) Disconnect the control cable of the pressure controller connector (8) Remove the pressure controller of the control tooling pressure switch TASK 26-20-50-750-801-A01 Bacharach Leak Test Do the leak test with a Sapre Leak detector or equivalent calibrated to 0,001kg/years, as follows: Make sure the leak detector is calibrated as specified in the operating instructions.
Page 35
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) Prepare to do the Hydrostatic Test NOTE : Do the hydrostatic test by the water-Jacket volumetric-expansion method specified in the Compressed Gas Association (CGA) Pamphlet C-1. Do not do the hammer test. Test persons must know the contents of CGA Pamphlet C-1 to make a correct analysis of the results.
Page 36
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) Divide the permanent expansion by the total expansion and multiply by 100 to calculate the percent of permanent expansion. If the total permanent volumetric expansion is more than 10 percent, discard the container. (3) Too much permanent expansion shows that the container wall is too thin or was in conditions that changed its dimensions.
Page 37
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) TASK 26-20-50-810-801-A01 Fault Isolation If a component fails a test, refer to table 1002 for the probable cause(s) and necessary actions. Table 1002 Fault Isolation TROUBLE PROBABLE CAUSE CORRECTIVE ACTION Container is nicked, dented or Incorrect handling Refer to CHECK section.
Page 38
The document reference is online, please check the correspondence between the online documentation and the printed version.
Page 39
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) DISASSEMBLY TASK 26-20-50-000-801-A01 General Do an inspection of the container before you disassemble it. Refer to CHECK section. Disassemble the container in the sequence given. See the IPL figure for the location of the parts.
Page 40
Agency's Clean Air Act of 1990 is to ban the release of Halon into the atmosphere unless it is necessary. In compliance with the preceding, L'HOTELLIER recommends that the extinguishing agent be caught and used again Check the purity of the halon in accordance with the ISO 7201 Norm (purity ≥ 99,7%;...
Page 41
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) Make sure that the valves A, B, C, D, E, G and H are closed. Refer to figure 7001 of ASSEMBLY section. WARNING : MAKE SURE ALL CONNECTIONS ARE TIGHT. REMOVE THE FIRE EXTINGUISHING AGENT IN AN AREA WITH A GOOD AIRFLOW. THE FIRE EXTINGUISHING AGENT IS VERY VOLATILE, BUT IS NOT EASILY FOUND BY ODOR.
Page 42
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) O ring Lockpin handle Charging Adaptor Figure 3001/GRAPHIC 26-20-50-99B-803-A01 Page 3004 26-20-50 APR 01/11 PRINTED IN FRANCE The document reference is online, please check the correspondence between the online documentation and the printed version.
Page 43
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) Holding Fixture Figure 3002/GRAPHIC 26-20-50-99B-804-A01 Page 3005 26-20-50 APR 01/11 PRINTED IN FRANCE The document reference is online, please check the correspondence between the online documentation and the printed version.
Page 44
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) Disc Assembly Weld-Machining Tool Figure 3003/GRAPHIC 26-20-50-99B-805-A01 Subtask 26-20-50-020-004-A01 Disc Assembly Cut the fused portion of each discharge outlet and disc assembly (100) with the disc assembly weld-machining-tool (refer to figure 3003) as follows: Put the cutter (2) into the guide bushing (1) and install the guide bushing and cutter assembly on the outlet on the container.
Page 45
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) Pressure Switch Weld-Machining Tool Figure 3004/GRAPHIC 26-20-50-99B-806-A01 Subtask 26-20-50-020-005-A01 Pressure Switch Put the container in the holding fixture with the pressure switch pointed up. Refer to figure 3002. Remove the pressure switch (220) from the container (230) with the pressure gauge weld- machining-tool (refer to figure 3004) as follows: Loosen the set screws and move the two halves of the tool apart.
Page 46
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) Fill Plug Weld-Machining Tool Figure 3005/GRAPHIC 26-20-50-99B-807-A01 Loosen the set screws and remove the tool. Look at the weld and make sure that the joint is broken. Remove the pressure switch (220) and shims (140, 150, 160,170) from the switch fitting .
Page 47
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) WARNING : YOU MUST REMOVE THE CONTENTS OF THE CONTAINER BEFORE YOU TURN THE FILL PLUG. IF THE CONTAINER IS FULL, YOU WILL RELEASE THE PRESSURIZED CONTENTS. ACCIDENTAL RELEASE OF THE PRESSURE IN THE CONTAINER IS DANGEROUS TO PERSONS.
Page 48
The document reference is online, please check the correspondence between the online documentation and the printed version.
Page 49
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) CLEANING TASK 26-20-50-100-801-A01 General This section gives the necessary instructions to clean the container and gives the materials to use. You can use equivalent materials. You must fully clean all openings on removed parts. Put protection caps and plugs on the openings before you touch, keep, or move the parts.
Page 50
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) WARNING : CONCENTRATION OF COMPRESSED AIR OR UNWANTED MATERIAL MOVED BY COMPRESSED AIR CAN CAUSE INJURY TO PERSONS. ALWAYS POINT COMPRESSED AIR AWAY FROM PERSONS. USE APPLICABLE EYE PROTECTION TO PREVENT INJURY TO YOUR EYES.
Page 51
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) CHECK TASK 26-20-50-200-801-A01 General Do an inspection to find damage and to make sure that the repair has been done correctly. Use the data in Table 5001 and the procedures to do the inspection.
Page 52
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) TASK 26-20-50-200-802-A01 Definition The definitions that follow are applicable to this section. Minimum Allowable Wall Thickness The minimum wall thickness is that thickness of the container metal given by the specification used to make the container.
Page 53
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) You must discard containers that have nicks deeper than 0,10 mm (0.004 in). You must discard containers that have nicks deeper than 0,10 mm (0.004 in). You must discard containers that have weld cracks or breaks.
Page 54
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) TASK 26-20-50-210-804-A01 Minimum Height of Neck Fitting Measure the neck for a minimum height of 1,5 mm (0.060 in). Refer to figure 5001. This is the minimum height necessary for the correct installation of a new disc assembly. Reject a container with less than the minimum neck height.
Page 55
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) Minimum Neck Height Figure 5001/GRAPHIC 26-20-50-99B-808-A01 Minimum Fill Fitting Height Figure 5002/GRAPHIC 26-20-50-99B-809-A01 Page 5005 26-20-50 APR 01/11 PRINTED IN FRANCE The document reference is online, please check the correspondence between the online documentation and the printed version.
Page 56
Table 5002 - Acceptance certificate PVR EXT N° ____________ (lot) IDENTIFICATION: EXTINGUISHER CARACTERISTIQUES : REFERENCE : Extinguisher agent type : 12589-01 Halon 1301 AMENDEMENT: Extinguisher agent weight : 1,200 kg 0/+0,045kg MFG: Theoretical nitrogen weight : 0,046 kg SERIAL NUMBER : Pressure at 20 °C :...
Page 57
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) REPAIR TASK 26-21-39-300-801-A01 General This section gives the data and procedures to repair the container. Also, the items that cannot be repaired, and must be replaced, are identified. TASK 26-20-50-940-804-A01 Tools, Fixtures, Equipment and Materials...
Page 58
The document reference is online, please check the correspondence between the online documentation and the printed version.
Page 59
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) NOTE : The applicable thread sizes are given in DESCRIPTION AND OPERATION section, Table 1, Specified Data. TASK 26-20-50-300-803-A01 Container External Surface Use 320 grit minimum sandpaper to remove any scratches and gouges in the permitted limits specified in CHECK section.
Page 60
The document reference is online, please check the correspondence between the online documentation and the printed version.
Page 61
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) NOTE : Make sure that the washer stays aligned with the flange on the fitting while you weld the washer to the fitting (9) Fuse weld the washer to the switch fitting assembly NOTE : If a blowout occurs, re-fuse the blowout area to prevent leakage.
Page 62
The document reference is online, please check the correspondence between the online documentation and the printed version.
Page 63
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) ASSEMBLY TASK 26-20-50-400-801-A01 General CAUTION: ONLY L’HOTELLIER MANUFACTURED/SUPPLIED SPARE PARTS AND COMPONENTS SHALL BE USED IN ACCORDANCE WITH THIS CMM L’HOTELLIER HAS NOT APPROVED ANY COMPONENTS OR SUBSTITUTE PARTS OF ANY KIND, OTHER THAN THOSE LISTED WITHIN THIS CMM. THE USE OF ANY SPARE PART OR COMPONENT OTHER THAN THOSE SPECIFIED WITHIN THIS CMM IS NOT AUTHORIZED BY L’HOTELLIER AND REPRESENTS NONCOMPLIANCE WITH THE PROCEDURES...
Page 64
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) Table 7001 Assembly Materials, Tool and Equipment DESCRIPTION PART NUMBER Bromotrifluoromethane (CBrF ISO 7201 ) Purity ≥ 99,995%; H O ≤ 5% ppm Nitrogen (N BB-N-411 Type I, Class A, Grade 1 Can contain methanol (concentration ≤ 2,5%)
Page 65
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) TASK 26-20-50-400-802-A01 Preparation for Assembly WARNING : DO THE HYDROSTATIC TEST BEFORE ASSEMBLY, IF NECESSARY. THIS WILL PREVENT POSSIBLE INJURY CAUSED BY CONTAINERS THAT BREAK OPEN. Preparation WARNING : CONCENTRATION OF COMPRESSED AIR OR UNWANTED MATERIAL MOVED BY COMPRESSED AIR CAN CAUSE INJURY TO PERSONS.
Page 66
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) Measure the outside diameter of the neck at the weld. Make sure that the diameter of the neck is not more than 37 mm (1.456 in). File the surplus welding to the value of 37mm...
Page 67
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) Make sure the pressure switch is correctly aligned. If the alignment is not correct, do steps B thru D again. If necessary, use the pressure switch weld-machining-tool (Figure 3005) to make the flange of...
Page 68
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) Connect the agent supply hose from valve A to valve B (Figure 7001) on the manifold. Connect the nitrogen supply hose to valve C on the manifold. Connect the hose from the manifold to the inlet of the cooling-bath coil.
Page 69
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) TO HALON STORAGE / REPROCESSING BENCH HALON NOTE : The cooling bath and cooling coil are not necessary if the agent supply cylinder is pressurized Recharge Kit Setup Figure 7001/GRAPHIC 26-20-50-99B-811-A01 Page 7007 26-20-50...
Page 70
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) TASK 26-20-50-410-805-A01 Container Fill WARNING : MAKE SURE THE CONTAINER DOES NOT CONTAIN PRESSURE FROM THE INTEGRITY AND LEAK TEST. BE CAREFUL WHEN YOU TOUCH OR MOVE THE CONTAINER. DO NOT TRY TO DISASSEMBLE THE CONTAINER.
Page 71
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) Close valves A, B, and E. NOTE : The cooling bath/coil is not necessary to do the fill procedure if the halon supply- cylinder is pressurized. NOTE : The cooling coil keeps 0.50 to 0.70 lb (0.23 to 0.32 kg) of CBrF .
Page 72
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) Do steps (1) and (2) until the nitrogen is absorbed and the container pressure becomes stable. NOTE : The container pressure is stable when the indication on the fill pressure gauge does not change when you shake the container.
Page 73
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) Apply The rust inhibitor to the burst disc on the fill-and-safety fitting as follows: (1) Put the application tube approximately 1.00 inc (2.54cm) into the inner diameter of the fill-and-safety fitting (2) Press the actuating plunger two times...
Page 74
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) Warning Label Figure 7004/GRAPHIC 26-20-50-814-A01 Container Identification Plate - Figure 7005/GRAPHIC 26-20-50-815-A01 Page 7012 26-20-50 APR 01/11 PRINTED IN FRANCE The document reference is online, please check the correspondence between the online documentation and the printed version.
Page 75
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) TASK 26-20-50-410-808-A01 Identification, weighing, and warning Labels Installation Remove the old label Clean the container with alcohol Put the label over the applicable area of the container and carefully install it on the container.
Page 76
The document reference is online, please check the correspondence between the online documentation and the printed version.
Page 77
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589 – () FITS AND CLEARANCES TASK 26-20-50-990-801-A01 General This section gives the necessary fits and clearances and torque values applicable to the assembly and installation of the container. There are no necessary fits and clearances for assembly of the container.
Page 78
The document reference is online, please check the correspondence between the online documentation and the printed version.
Page 79
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) SPECIAL TOOLS, FIXTURES AND EQUIPMENT AND CONSUMABLE TASK 26-20-50-940-806-A01 General This section gives the special tools, fixtures, equipment and consumables that are necessary to keep the fire extinguisher container serviceable Special tools, fixtures and equipment are given in Table 9001. Refer to figures 9001, 9002, 9003, 9004 and 9005.
Page 80
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) Table 9001 Special Tools, Fixtures, and Equipment SOURCE DESCRIPTION PART NUMBER SPECIFICATION (CAGE CODE) Hydrostatic pressure test None Compressed gas Make locally setup (Water Jacket) association (CGA) pamphlet C-1 Retainer torque adapter OUT751924-00 None L’Hotellier...
Page 81
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) Consumable materials are given in Table 9002. NOTE : You can use equivalent alternatives for the items given in the table Table 9002 Consumable Materials SOURCE DESCRIPTION PART NUMBER SPECIFICATION (CAGE CODE) Bromotrifluoromethane None...
Page 82
The document reference is online, please check the correspondence between the online documentation and the printed version.
Page 83
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) ILLUSTRATED PARTS LIST IPL 10001 Page 1/2 26-20-50 APR 01/11 PRINTED IN FRANCE The document reference is online, please check the correspondence between the online documentation and the printed version.
Page 84
The document reference is online, please check the correspondence between the online documentation and the printed version.
Page 85
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) INTRODUCTION TASK 26-20-50-990-802-A01 General The Illustrated Parts List (IPL) is prepared in compliance with ATA 100. The IPL is intended to identify all the components of the unit. The illustrated parts list contains the following sections :...
Page 86
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) Manufacturer's part number Each of the assemblies, sub-assemblies and detail parts, illustrated or not, is assigned a manufacturer's part number. When the manufacturer's actual part number exceeds 15 characters, an equivalent assigned part number is listed in the "Part Number" column preceded by the following annotation: ORDER OVERLGTH..MADE BY V..
Page 87
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) Units per assembly The units per assembly column shows the number of units required for the next higher assembly. In some cases this information is replaced by the letters "REF" (reference) or "AR" (as required).
Page 88
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) SUPSDS Supersedes UNDERSIZE Undersize repair parts TASK 26-20-50-990-805-A01 Updating When an item is revised, added or deleted, the letter "R" is shown in the LH margin (the page date issue changes). The letter "R" appears in the LH margin opposite the page number when all the item numbers are changed.
Page 89
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) TASK 26-20-50-980-801-A01 VENDOR NAME – ADRESS CODE VF9211 L’HOTELLIER 4, rue Henri Poincaré 92167 Antony Cedex FRANCE VCI 10001 Page 1/2 26-20-50 APR 01/11 PRINTED IN FRANCE The document reference is online, please check the correspondence between the online documentation and the printed version.
Page 90
The document reference is online, please check the correspondence between the online documentation and the printed version.
Page 91
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) TASK 26-20-50-970-801-A01 PART NUMBER AIRLINE STOCK NO. ITEM TTL REQ E2003 10001 KIT12589-01 10001 - ITEM NOT ILLUSTRATED NI/ALPHA 10001 Page 1/2 26-20-50 APR 01/11 PRINTED IN FRANCE The document reference is online, please check the correspondence between the online documentation and the printed version.
Page 92
The document reference is online, please check the correspondence between the online documentation and the printed version.
Page 94
The document reference is online, please check the correspondence between the online documentation and the printed version.
Page 95
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) DETAILED PARTS LIST DPL 10001 Page 1/2 26-20-50 APR 01/11 PRINTED IN FRANCE The document reference is online, please check the correspondence between the online documentation and the printed version.
Page 96
The document reference is online, please check the correspondence between the online documentation and the printed version.
Page 97
COMPONENT MAINTENANCE MANUAL 12589-( ) 130 (*) 120 (*) 110 (*) 100 (*) Container-Aircraft Fire Extinguisher 12589-01 Figure 10001 (sheet 1) - GRAPHIC 26-21-37-99B-901-A01 (*) These parts are included in the repair kit (090) Page 10001-1 26-20-50 APR 01/11 PRINTED IN FRANCE...
Page 98
190 (*) 180 (*) 170 (*) 160 (*) 150 (*) 140 (*) Container-Aircraft Fire Extinguisher 12589-01 Figure 10001 (Sheet 2) - GRAPHIC 26-20-50-99B-901-A01 (*) These parts are included in the repair kit (090) Page 10001-2 26-20-50 APR 01/11 PRINTED IN FRANCE...
Page 99
TASK 26-20-50-950-801-A01 UNIT AIRLINE NOMENCLATURE FIG. ITEM PART NUMBER STOCK NO. CODE ASSY. 1234567 -001 12589-01 Fire extinguisher 010 863487-00 .Protection anti recoil cap 020 E2003 .Coupling 030 12466-00 .Protection anti recoil cap 040 13130-00 .Discharge head body 050 13363-00 .Screen, debris...
Page 100
The document reference is online, please check the correspondence between the online documentation and the printed version.
Page 101
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) STORAGE (INCLUDING TRANSPORTATION) TASK 26-20-50-550-801-A01 Storage and Handling ° ° WARNING : AN AMBIENT TEMPERATURE MORE THAN 212 F (100 C) CAN CAUSE DAMAGE TO THE CONTAINER BECAUSE OF TOO MUCH PRESSURE. DO NOT DROP THE CONTAINER.
Page 102
L'HOTELLIER COMPONENT MAINTENANCE MANUAL 12589-( ) Identify the cardboard box with an applicable label. Refer to the applicable shipping regulation in Table 15001. Table 15001 Labeling and Shipping Regulations GOVERNING REGULATION (S) SHIPPING METHOD UE. DOMESTIC INTERNATIONAL International Air Transport...