All Intellectual Properties, as defined below, owned by or which is otherwise the property of Chemyx Inc. or its suppliers relating to the Chemyx syringe pumps, including but not limited to, accessories,
parts or software relating thereto (Chemyx Syringe Pumps), are proprietary to federal and state laws, and international treaty provisions. Intellectual Property includes but is not limited to, inventions
(patentable or unpatentable), patents, trade secrets, copyrights, software, firmware, computer programs, and related documentation and other works of authorship. Moreover, you agree that you will
not, and will not attempt to, modify, prepare derivative works of, reverse engineer, disassemble the Chemyx syringe pumps, decompile or otherwise attempt to create source code from the related
software/firmware. No title to or ownership in Intellectual Property is transferred to you. All applicable rights of the Intellectual Property shall remain with Chemyx and its suppliers.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OEM 30050 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Chemyx OEM 30050

  • Page 1 INTELLECTUAL PROPERTY All Intellectual Properties, as defined below, owned by or which is otherwise the property of Chemyx Inc. or its suppliers relating to the Chemyx syringe pumps, including but not limited to, accessories, parts or software relating thereto (Chemyx Syringe Pumps), are proprietary to federal and state laws, and international treaty provisions. Intellectual Property includes but is not limited to, inventions (patentable or unpatentable), patents, trade secrets, copyrights, software, firmware, computer programs, and related documentation and other works of authorship.
  • Page 2: Table Of Contents

    Table of Contents EU Declaration of Conformity (DoC) Safety Information Product Overview Product Drawings Data Sheet Loading a Syringe Pump Control by Computer Conytroller Programs Commands Pump Maintenance Syringe Pump Accessories Warranty and Repair Information Appendix A: Syringe Volume/Diameter Reference Table...
  • Page 3: Eu Declaration Of Conformity (Doc)

    The technical documentation required to demonstrate that the products meet the requirements of the LV and EMC directives has been compiled and is available for inspection by the relevant enforcement authorities. Signature on behalf of manufacturer: Jeff Wu, Senior Engineer, Chemyx, Inc. Authority: Date: March 1, 2018 Date: Attention! The attention of the specifier, purchaser, installer, or user is drawn to special measures and limitations to use which...
  • Page 4: Safety Information

    CHEMYX PRODUCTS ARE NOT APPROVED FOR CLINICAL USE ON HUMANS. Use Proper Power Supply Chemyx is not responsible for the use of power supplies outside the stated electrical specifications or failure to switch the power converter from 220V to 110 V while in the 220V environment or vice versa.
  • Page 5: Product Overview

    OEM Full Case Module - Model 30060 The Chemyx OEM syringe pump is a bolt-on microfluidic pump designed for integration into analytical instruments requiring precision flow functionality with a removable syringe. OEM series syringe pumps are capable of delivering microliter accurate flows from a wide range of syringe sizes.
  • Page 6: Product Drawings

    Product Drawings OEM Drawings - Model 30050...
  • Page 7 Product Drawings OEM Drawings - Full Case Model 30060...
  • Page 8: Data Sheet

    Data Sheet OEM Modules Model SKE 50 - Data Sheet OEM - Model 30050 OEM Full Case Module - Model 30060 0.0001ul/min (with 0.5ul syringe) 140mL/min (with 50mL syringe) 6*$F= 24 DC !"#$%&"'%&( ((((((((((((((((( DIMENSIONS ! "#$%&'($)$*"+$,-./$)$+"#$01%%$-'23/4$$566"6$)$77$)$8"9$2:;$ 8.7 long x 4.3 wide x 3.7 tall inches (22.2 x 11 x 9.5 cm) !"#$%&"'%&( ((((((((((((((((( ! "#$%&'($)$*"+$,-./$)$+"#$01%%$-'23/4$$566"6$)$77$)$8"9$2:;$...
  • Page 9: Loading A Syringe

    Loading a Syringe The OEM can accommodate one syringe. The volume of the syringes can vary from a minimum of 0.5 μL up to a maximum of 60 mL. Syringes of any material (e.g., glass, plastic, stainless steel, etc.) can be used; however, some use cases may require syringes that are more accurate and durable.
  • Page 10: Pump Control By Computer

    The OEM syringe pumps can be controlled with an external computer using an RS232 serial connection. Cable Requirements Two types of connections are available for external computer control: DB9 and USB, cables for each are available for purchase through Chemyx (call 1-281-277-5499 or visit www.chemyx.com/contact-us). USB-A to USB-B cable DB9 Serial Cable (Male-to-Female) TTL Connection For the DB9 serial connection, a Male-to-Female DB9 cable must be used.
  • Page 11: Conytroller Programs

    Chemyx Pump Controller Programs In addition to the manual control of the pumps through a terminal, Chemyx provides pump controller programs as an unsupported open-source applications written in Python, a LabVIEW package, and a MATLAB package. More information on these tools can be found on the website at www.chemyx.com/support.
  • Page 12: Commands

    Quick Start Guide - Commands IMPORTANT RS232 Protocol/Commands * Explanation of command function is located after command name* ALWAYS connect RS232 and RS232 Comport Settings: All system from 11/1/2010 Power supply BEFORE powering Bits per seconds - 38400 Data bits - 8 on the OEM Module! Parity - None Stop bit - 1...
  • Page 13: Pump Maintenance

    Pump lubrication should be performed every three months. Approved Lubricants • Engine/motor oil • Silicone oil • Machine oil • Tooling oil or “WD-40” • Lithium-based grease Please contact Chemyx call +1 281-277-5499 or email us at info@chemyx.com to confirm the safe use of a different lubricant.
  • Page 14: Syringe Pump Accessories

    Syringe Pump Accesories Streamline laboratory operations with this electric foot switch control that lets you start, stop, or pause your Chemyx syringe pump systems— even when your hands are full. The electric foot pedal switch connects seamlessly to computerized pumping programs, and its 10-foot cable connection can be customized for either the Nexus series (DB9 connection) or the Fusion 100/200/4000/6000 (USB-B connection).
  • Page 15: Warranty And Repair Information

    Warranty Information Chemyx provides a two-year limited warranty (1) first-year for parts and labor (2) second-year for parts only from the shipment date for its pumps against defects in materials and workmanship. Chemyx will repair any product that proves defective during its stated warranty period.
  • Page 16: Appendix A: Syringe Volume/Diameter Reference Table

    Appendices Appendix A: Syringe Volume/Inner Diameter Reference Chemyx Stainless Steel Hamilton Glass Size Diameter Inner | Outer Size Diameter 6.00 mL 9.5 mm inner | 13mm outer 0.50 μL 0.10 mm 20.00 mL 19.1 mm inner | 23 mm outer 1.00 μL...
  • Page 17 JMC Air-Tite Plastic Norm-Ject Plastic Size Diameter Size Diameter 1.00 mL 4.66 mm 1.00 mL 4.70 mm 2.00 mL 6.90 mm 2.50 mL 9.70 mm 2.50 mL 9.10 mm 5.00 mL 12.48 mm 5.00 mL 12.62 mm 10.00 mL 15.89 mm 10.00 mL 14.34 mm 20.00 mL...
  • Page 18 SGE Glass Terumo Japan Size Diameter Size Diameter 25.00 μL 0.73 mm 1.00 mL 4.73 mm 50.00 μL 1.03 mm 1.00 mL 6.50 mm 100.00 μL 1.46 mm 3.00 mL 8.65 mm 250.00 μL 2.30 mm 5.00 mL 13.00 mm 500.00 μL 3.26 mm 10.00 mL...
  • Page 19 Unimetrics Size Diameter 10.00 μL 0.46 mm 25.00 μL 0.73 mm 50.00 μL 1.03 mm 100.00 μL 1.46 mm 250.00 μL 2.30 mm 500.00 μL 3.26 mm 1000.00 μL 4.61 mm Kendall Monoject Plastic Size Diameter 1.00 mL 4.65 mm 3.00 mL 8.94 mm 6.00 mL...