SUPPLEMENTAL INSTRUCTIONS

Description

The CMC-32 is a field-installable start kit. It is a
positive temperature coefficient resistor (PTCR) that
increases starting torque by momentarily increasing the
current to the start winding of the compressor.
For use with all "A" electrical version wall-mount air
conditioners and heat pumps.
The CMC-32 consists of:
7960-856 Supplemental Instructions
910-2004 PTCR
1012-065 Phillips Head Screw
7961-312-0513 CMC-32 Unit I.D. Label

Field-supplied tools needed:

Personal protection equipment, including gloves
and safety glasses
5/16" nut driver
Phillips head screwdriver
Small flat head screwdriver for securing wire in
terminal blocks
Multimeter for troubleshooting
CMC-32 Start Kit
Bard Manufacturing Company, Inc.
Bryan, Ohio 43506
www.bardhvac.com
WARNING
!
Electrical shock hazard.
Disconnect the remote electric power
supply or supplies before servicing.
Failure to do so can result in serious injury
or death.
WARNING
!
Exposed moving parts.
Disconnect all electrical power before
servicing.
Failure to do so can result in severe injury
or amputation.
CAUTION
!
Sharp metallic edges.
Take care and wear appropriate protective
devices to avoid accidental contact with
sharp edges.
Failure to do so can result in personal
injury.
Manual:
Supersedes: NEW
Date:
7960-856
9-24-19
Page
1 of 2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CMC-32 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Bard CMC-32

  • Page 1 SUPPLEMENTAL INSTRUCTIONS CMC-32 Start Kit Description WARNING The CMC-32 is a field-installable start kit. It is a positive temperature coefficient resistor (PTCR) that increases starting torque by momentarily increasing the Electrical shock hazard. current to the start winding of the compressor.
  • Page 2 4. Connect wires between terminals (HERM) and (C) of dual can capacitor as shown in Figure 1. 5. Recheck wiring. Refer to Figure 1. 6. Attach “CMC-32” label above the wiring diagram on the inner control panel cover. 7. Replace all panels and covers. This completes the installation.

Table of Contents