Page 1
Split Manifold Kits 308439E ™ Converts Husky 307 Diaphragm Pump to dual fluid inlet or outlet Part No. 237210 For Husky 307 Polypropylene Pumps Part No. 237211 For Husky 307 Acetal Pumps Important Safety Instructions Read all warnings and instructions in the...
Page 2
To raise the fluid level in the tray, close valve N and open valve P. This is a basic system. Additional equipment such as solenoids and float valves can be used for automated systems. See your Graco representative Fluid for details. Supply 03914 Fig.
Page 3
Installation Installation Procedure WARNING Pressure Relief Procedure To reduce the risk of serious injury, including splashing fluid or solvent in the eyes or on the skin, follow this procedure before installing this kit: 1. Shut off the air to the pump. 2.
Page 4
Installation Installing a Split Outlet Manifold Installing a Split Inlet Manifold Part of pump; not supplied in kit. Apply thread lubricant. Torque to 50-60 in-lb (5.6-6.8 N•m). Do not over-torque. See the WARNING below. 03912 Fig. 4 ________________________________________________________________________________________ WARNING The warning label (2) included in the kit contains important information for the safe operation of this pump. Clean the surface of the cover (C) with a compatible solvent and secure the label as shown.
With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.