Ensemble Designs Avenue 5820 Data Pack

Ensemble Designs Avenue 5820 Data Pack

Gpi/serial interface

Advertisement

Quick Links

GPI/Serial Interface
E
N S E M B L E
D
E
S
I
G
This data pack provides detailed installation, configuration and operation information for
the 5820 GPI/Serial Interface Module as part of the Avenue Signal Integration
System.
The module information in this data pack is organized into the following sections:
• Module Overview
• Applications
• Installation
• Cabling
• Module Configuration and Control
Front Panel Controls and Indicators
°
Avenue PC Remote Control
°
Avenue Touch Screen Remote Control
°
• Troubleshooting
• Software Updating
• Warranty and Factory Service
• Specifications
Model 5820
Data Pack
N
S
Revision 2.1 SW v1.1.0
5820-1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Avenue 5820 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ensemble Designs Avenue 5820

  • Page 1 Model 5820 GPI/Serial Interface Data Pack N S E M B L E Revision 2.1 SW v1.1.0 This data pack provides detailed installation, configuration and operation information for the 5820 GPI/Serial Interface Module as part of the Avenue Signal Integration System.
  • Page 2: Module Overview

    Model 5820 GPI/Serial Interface Module MODULE OVERVIEW The 5820 GPI/Serial Interace module extends the capability of the Avenue control system by enabling third party interfaces to control Avenue modules through memory register recall. The 5820 provides General Purpose Interface control (GPI contact closure) over modules located anywhere in the Avenue system.
  • Page 3: Installation

    Model 5820 GPI/Serial Interface Module APPLICATIONS As shown below, the 5820 receives GPI information from a third party automation system. The module is then configured to send messages to any Avenue module on the network to recall memory registers. The optional Remote Control Panel shown here can monitor status of the GPI inputs.
  • Page 4 Model 5820 GPI/Serial Interface Module Control Interface Option Three types of devices can control the 5820 module: An application specific control panel (or multiple control panels), a customer-supplied GPI device and an external device (such as a PC) using a Serial port connection. Connection to the Remote Control Panel and the GPI device to the 5820 module and the cable pinouts for each application are given below.
  • Page 5 Model 5820 GPI/Serial Interface Module GPI Control An external customer-supplied GPI device can be connected to the Control connector on the rear of the 5820 module to trigger the GPI inputs by user-defined actions. Connect the GPI control to the 5820 Control connector pins as shown below. Each GPI pushbutton should be wired with closure to ground to trigger a crosspoint.
  • Page 6: Module Configuration And Control

    Model 5820 GPI/Serial Interface Module MODULE CONFIGURATION AND CONTROL The eight GPI inputs on the 5820 module must be mapped to the Avenue modules to be controlled using the menus in the Avenue PC application or an Avenue Touch Screen Panel.
  • Page 7 Model 5820 GPI/Serial Interface Module Avenue PC Remote Configuration The Avenue PC remote control status menu for this module is illustrated and explained below. For more information on using Avenue PC, refer to the Avenue PC Control Application Software data pack that came with the option. 5820 Avenue PC Menus There are eight GPI menus in the Avenue PC application, GPI 1 –...
  • Page 8 Model 5820 GPI/Serial Interface Module Avenue Touch Screen Remote Configuration The Avenue Touch Screen remote control status menu for this module is illustrated and explained below. For more information on using Avenue Touch Screen, refer to the Avenue Touch Screen data pack that came with the option. 5820 Avenue PC Menus There are eight GPI menus in the Avenue touch Screen Panel application, GPI 1 –...
  • Page 9: Troubleshooting

    Model 5820 GPI/Serial Interface Module TROUBLESHOOTING As a troubleshooting aid, power and CPU status can be easily monitored from the front panel of this module using the indicators explained in the previous section. The following status items can be monitored using the Avenue Touch Screen Control Panel or PC Application: •...
  • Page 10: Warranty And Factory Service

    If you return equipment for repair, please get a Return Material Authorization Number (RMA) from the factory first. Ship the product and a written description of the problem to: Ensemble Designs, Inc. Attention: Customer Service RMA ##### 870 Gold Flat Rd.
  • Page 11: Specifications

    Model 5820 GPI/Serial Interface Module SPECIFICATIONS 5820 GPI/Serial Interface Input Signal: Number: Eight GPI One RS-232/RS-422 General Specifications Power Consumption: < 5.0 Watts Temperature Range: 0 to 40 degrees C ambient (all specs met) Relative Humidity: 0 to 95% noncondensing Altitude: 0 to 10,000 ft Fusing:...