ALLED3 Series Area Lights
BEFORE YOU BEGIN
Read and follow all safety instructions
RISK OF FIRE, EXPLOSION AND ELECTRIC SHOCK
•
This product should be installed, inspected, and maintained by a qualified electrician only,
in accordance with the NEC (National Electric Code) and all local codes.
•
Turn off electrical power before inspection, installation or removal.
•
Use only UL (or other NTRL) approved wire for input/output connections.
Minimum size 18 AWG or 14 AWG for continuous runs.
•
Make sure LEDs and drivers are cool to touch when performing maintenance.
Make sure the supply voltage is the same as the rated voltage of the luminaire.
•
Do not install in a hazardous atmosphere, except where the ambient temperature does
not exceed the rated operating temperature of the fixture.
•
Keep tightly closed when in operation
Prepare Electrical Wiring
Electrical Requirements
The LED driver must be supplied with 120 to 277V, 50/60 Hz
(or 347 to 480V, 50/60 Hz, when applicable - refer to product label)
and connected to an individual, properly grounded branch circuit
protected by a 20 Ampere circuit breaker. Use min. 75°C supply.
Grounding Instructions
The grounding and bonding of the overall system shall be
done in accordance with NEC Article 600 and local codes
SAVE THESE INSTRUCTIONS
WARNING
Installation Guide