1. Important Notice 1. Important Notice: 1-1 Regulations 1-1 REGULATIONS This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
1. Important Notice 1-2 RoHS DIRECTIVE 1-2 RoHS DIRECTIVE The RoHS directive (European Parliament Directive 2002/95/EC) mandates that producers of electrical or electronic equipment sold into Europe must minimize or eliminate the following materials from their design, as they are considered health risks: 1.
2. Introduction 2-3 PACKAGE INFORMATION 2-3 PACKAGE INFORMATION The contents of the package may vary depending on your order. While some primary devices avail the users of their fundamental functionality, some optional items are also available for your purchase to maximize efficiency of our product. Inside the package contain the following items: Passport Reader Simple Manual...
3. Scanner Configuration 3. Scanner Configuration 3-1 CONFIGURATION BY USER MANUAL 3-1 Configuration by USER MANUAL In the user manual, print out the related topics of setting page, simply use the scanner to scan the barcode for configuration. For example: ENTER */$%ENTR* (Enter configuration)
3. Scanner Configuration 3-2 Configuration by SOFTWARE 3-2 CONFIGURATION BY SOFTWARE In the product CD, you can find configuration software “Normal command setting” to configure the parameters. Scanner general settings: (CM-2D700\Software\Normal command setting\Scanner Setting.exe) Note: Please refer to the related configuration chapters or additional manual for how to use the software.
4. General Setting Chapter 4: General Setting 4-1 General Cable Mode Setting 4-1-1 Mode 4-1-2 Output Interface 4-1-3 App Type 4-1-4 Key0Mode 4-1-5 Scan Activation Time 4-1-6 GoodRead Beep Volume 4-1-7 Warning Beep Volume 4-1-8 Power on light 4-1-9 Good Read Beep Freq 4-1-10 Good Read Beep Time 4-1-11 Transmission Code length 4-1-12 Force Case...
4. General Setting 4. General Setting 4-1 General Cable Mode Setting 4-1 General Cable Mode Setting 4-1-1 Mode 4-1-1 Mode This function to set operation Mode: (1) Good Read Off: When pressing “Scan” key, turning on scanning light, scanning barcode correctly or over loading time to make barcode scanning incorrectly, the light will be turned off.
4. General Setting 4-1-2 Output Interface 4-1-2 Output Interface Please scan the appropriate barcode to specify the output interface *3HV1* *3HV2* Usb-Hid Usb-Spp(Virtual COM) 4-1-3 App Type 4-1-3 App Type Whether to enable special setting Normal: Do not enable Normal Normal Normal MobilePhone: When scanning the barcode on the phone, to set up this function for...
4. General Setting 4-1-5 Scan Activation Time 4-1-5 Scan Activation Time In general, after Scan Button is pressed down, LED light will emit a stream of light for a scan attempt. This parameter is thus used to specify activation duration which indicates the amount of time LED light will stays on after Scan button is pressed.
4. General Setting 4-1-7 Warning Beep Volume 4-1-7 Warning Beep Volume Scan the appropriate barcode to disable Warning Buzzer or set Warning Buzzer volume when Warning or error occurred. *3I30* *3I31* Disable Level1 *3I32* *3I33* Level2 Level3 *3I34* Level4 4-1-8 Power on light 4-1-8 Power on light When the scanner is on, whether to turn on the scanning light automatically.
4. General Setting 4-1-9 Good Read Beep Freq 4-1-9 Good Read Beep Freq When decoding successfully, it will make a sound, and you can use this setting to set Beep Frequency. *6IO+* Configuration Range Unit Default Setting 100 ~ 3500Hz 100Hz 2700 Hz Procedure...
4. General Setting 4-1-11 Transmission Code Length 4-1-11 Transmission Code Length If user needs to know the length of the barcode data, this configuration enables to indicate the barcode length in front of barcode data. *7SO0* Disable *7SO1* Enable 4-1-12 Force Case 4-1-12 Force Case This configuration enables to convert all output digits to be same printing-case;...
4. General Setting 4-1-13 Transmission Code ID 4-1-13 Transmission Code ID When scanning the barcode, User might want to know the symbology of the barcode ID, This configuration enables to display the Code ID. *4SL0* Disable *4SL1* Enable 4-1-14 Code ID Position 4-1-14 Code ID Position When “Transmission Code ID”...
4. General Setting 4-1-15 Transmission Code Name 4-1-15 Transmission Code Name This configuration enables to show the barcode symbology name. Symbology name will be showing in front of barcode data. *3SK0* Disable *3SK1* Enable 4-1-16 Preamble code 4-1-16 Preamble code Preamble Code refers to a sequence of characters which precedes both Prefix Code and barcode data during data transmission.
4. General Setting 4-1-25 BarUtf8Convert 4-1-25 BarUtf8Convert 1. If the barcode is not encoded in Utf8, then the parameter has to be set as "None". 2. If the barcode is endoced in Utf8, then please set "Big5", "Gb2312" or "Sjis" according to the language of user's preference. *4SU0* *4SU3* None...
4. General Setting 4-2 Scanner Configuration by Software 4-2 Scanner Configuration by Software 4-2-1 Firmware Update 4-2-1 Firmware Update Open the software” Normal command setting” Connect scanner with PC by USB cable, and set the scanner to ISP mode. Scan below barcodes to set the scanner to ISP mode. */$%ENTR* 1.
Page 42
4. General Setting When the scanner is in ISP mode, the PC might request for driver installation, the driver is located in the CD (\CM-2D700\driver\USBCOM.inf). After the scanner scan Enter. ISP barcode, the LED indicator will be flashing, then proceed to “Device Manager” to check COM Port For example: The COM Port used by scanner is COM7 In Normal command setting software, “Sync Properties”...
Page 43
4. General Setting Under “Communication Download Kernel” Select the kernel file ( for example: 0001-0001.Bin) Select ”Open” for firmware update When firmware update is successful, as the following picture: To click ”OK” button to finish this setting. After firmware updated, please exit the software. The scanner will reboot.
4. General Setting 4-2-2 Scanner Configuration 4-4-2 Scanner Configuration Open the software” Normal command setting” Connect scanner with PC by USB cable, and set the scanner to ISP mode. Scan below barcodes to set the scanner to ISP mode. */$%ENTR* 1.
Page 45
4. General Setting After the scanner scan Enter. ISP barcode, the LED indicator will be flashing, then proceed to “Device Manager” to check COM Port For example: The COM Port used by scanner is COM7 In Normal command setting software, “Sync Properties”...
Page 46
4. General Setting User can change the settings of scanner (For example, enable Msi) Save the “configure content” and specified a file name in your local drive. Under “Communication Download Setting File”, the settings will download to the scanner. After configuration updated, please exit the software. The scanner will reboot. Note: For detail configuration, please refer to additional manual “barcode scanner user manual”(\CM-2D700\Manuals\User manual for setting software on 2D barcode scanner.pdf)
5: General Configuration Setting 5. General Setting Chapter 5: General configuration setting 5-1 Host Interface 5-1-1 Version 5-1-2 Abort Setting 5-1-3 ISP Mode 5-1-4 Barcode Default 5-1-5 All Default 5-2 Output Interface 5-2-1 Out-HID(USB-Hid) Type 5-2-1-1 Caps Lock 5-2-1-2 Numeric Key 5-2-1-3 Shift Release Caps Lock 5-2-1-4 Transmission Timeout 5-2-1-5 Transmission Char Delay...
Page 48
5: General Configuration Setting 5. General Setting 5-3-4 STX Character 5-3-5 Setup Time Note: It is recommended to print out the Hexadecimal / Decimal table (page: 251) for parameter setting.
5: General Configuration Setting 5. General Setting 5. General Configuration Setting 5-1 Host Interface 5-1 Host Interface 5-1-1 Version 5-1-1 Version Firmware information listing, the scanner firmware information included the ISP version, the firmware version , Mde and 2D Engine version. *ZVER* Procedure: (1) Scan “Enter”...
5: General Configuration Setting 5. General Setting 5-1-3 ISP Mode 5-1-3 ISP Mode For software configuration, User must connect the scanner with PC via USB cable, and scan “Enter “, “ISP” to enter the ISP mode. (PC might request for Driver installation, please find the driver file “USBCOM.inf ”...
5: General Configuration Setting 5. General Setting 5-2 Output Interface 5-2 Output Interface User can connect the scanner with PC via USB cable to be used as real time USB scanner. There are two different output Interfaces: (1) Out-Hid(USB-Hid) Type: With Out-Hid type, user can use Word, Excel or any word processing software to receive barcode data.
5: General Configuration Setting 5. General Setting 5-2-1 Out-HID(USB-Hid) Type 5-2-1 Out-HID(USB-Hid) Type 5-2-1-1 Caps lock Caps lock setting for the barcode data display. *3750* *3751* Auto LowerCase *3752* *3753* UpperCase Alt+ Example Barcode data "ABCdef" Status Caps Lock On Caps Lock Off Selection UpperCase ABCdef...
5: General Configuration Setting 5. General Setting 5-2-1-3 Shift Release Caps Lock Scan the following barcode can let the user to press ”Shift” to release the status of Caps Lock. *5770* Disable *5771* Enable 5-2-1-4 Transmission Timeout After sending the information, how long time did not respond will start timeout *27V+* Configuration Range Unit...
5: General Configuration Setting 5. General Setting 5-2-1-5 Transmission Char Delay After setting the number of characters transmitted into the Delay Time *37W+* Configuration Range Default Setting 0 ~ 255 Procedure (A) Scan “Enter” barcode (B) Scan “Transmission Char Delay” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“...
5: General Configuration Setting 5. General Setting 5-2-1-7 Transmission Record Gap Time This function can set Delay Time between 2 records. *57Y+* Configuration Range Unit Default Setting 0 ~ 2550 ms 10 ms Procedure: Example: (A) Scan “Enter” barcode If configuration is 200 ms, the (B) Scan “Transmission Record Gap parameter value is 200ms / 10ms = Time”...
5: General Configuration Setting 5. General Setting 5-2-1-8 Layout Setting The function enables the user to specify HID keyboard language. *6780* *6786* Spanish *6781* *6787* Portuguese *6782* *6788* Japanese Slovakia *6783* *6789* France Korea *6784* *678A* Germany Turkey *6785* Italian 5-2-1-9 Output Language To set up the target barcode encoding *7790*...
5: General Configuration Setting 5. General Setting 5-2-2 Out-SPP(Virtual COM) Type 5-2-2 Out-SPP(Virtual COM) Type 5-2-2-1 “Ack/Nak” Responese Whether to enable ” Ack/Nak” responese function *4850* None *4851* Ack/Nak 5-2-2-2 <STX> & <ETX> Characters Scan below barcodes to set if need to add STX data (before the output barcode data) &...
5: General Configuration Setting 5. General Setting 5-2-2-3 Command Mode Scan the appropriate barcode to enable or disable Command mode for SPP *7880* Disable *7881* Enable 5-2-2-4 Retransmission Count To avoid data transmission loss, messages sometimes have to be resent due to a failure to receive ACK signal;...
5: General Configuration Setting 5. General Setting 5-2-2-5 ACK Timeout To set up the period of time to receive ACK after sending data *68P+* Configuration Range Unit Default Setting 2 ~ 255 sec 1 sec 3 secs Procedure: Example: (A) Scan “Enter” barcode If configuration is.2 sec, the (B) Scan “ACK Timeout”...
5: General Configuration Setting 5. General Setting 5-2-2-7 Transmission Char Delay After setting the number of characters transmitted into the Delay Time *08S+* Configuration Range Default Setting 0 ~ 255 Procedure (A) Scan “Enter” barcode (B) Scan “Transmission Char Delay” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“...
5: General Configuration Setting 5. General Setting 5-2-2-9 Transmission Record Gap Time This function can set Delay Time between 2 records. *28U+* Configuration Range Unit Default Setting 0~2550 ms 10 ms 0 ms Procedure: Example: (A) Scan “Enter” barcode If configuration is 200 ms, the (B) Scan “Transmission Record Gap parameter value is 200 ms / 10 ms = Time”...
5: General Configuration Setting 5. General Setting 5-3 System Control 5-3 System Control 5-3-1 System Beep Sw 5-3-1 System Beep Sw Whether it needs to disable Beep sound of system category (like power on music) or set the Beep volume of the system category. *13P0* *13P1* Level1...
5: General Configuration Setting 5. General Setting 5-3-2 Data Link Escape Character 5-3-2 Data Link Escape Characters Set Escape digits *44I+* Configuration Length Default Setting 0x10 Procedure: (A) Scan “Enter” barcode (B) Scan “Data Link Escape Character” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“...
6: Symbology Settings 6-2-7 Coupon Gs1DataBar Output 6-2-7 Coupon Gs1DataBar Output When scanning the barcode data of UPC and GS1 Databar at the same time, whether to only indicate the content of GS1 Databar *JVD0* Disable *JVD1* Enable 6-2-8 ExtendedCouponCode 6-2-8 ExtendedCouponCode Use the following codes to enable or disable UPC-A and EAN-13with Extended coupon code:...
6: Symbology Settings 6-2-9 Wait Addon Time 6-2-9 Wait Addon Time Wait for decoding additional code, need to use” Wait Add-on” ; If to get the additional code in a specified decoding time, then indicate, otherwise do not indicate *KVE+* Configuration Range Unit Default Setting...
6: Symbology Settings 6-2-11 TruncateLeading 6-2-11 TruncateLeading To set up the number of digits to be omitted from the beginning of the barcode *I0Y+* Configuration Range Default Setting 0~12 Procedure: (A) Scan “Enter” barcode (B) Scan “TruncateLeading” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“...
6: Symbology Settings 6-2-13 TruncateZero 6-2-13 TruncateZero Whether to omit 0 from the beginning of the barcode *N120* Disable *N121* Enable Insertion1DataPosition 6-2-14 6-2-14 Insertion1DataPosition To set up the position to insert data1 *P14+* Configuration Range Default Setting 0~12 Procedure: (A) Scan “Enter”...
6: Symbology Settings 6-3 UPC-E 6-3 UPC-E 6-3-1 Read 6-3-1 Read Whether the barcode can be scanned *MVG0* Disable *MVG1* Enable 6-3-2 Expansion 6-3-2 Expansion This expansion function is for UPC-E only. It will extend the barcode to be 12-digits by “0“. *OVI0* Disable *OVI1*...
6: Symbology Settings 6-3-8 Wait Addon Time 6-3-8 Wait Addon Time Wait for decoding additional code, need to use ” Wait Add-on” ;If to get the additional code in a specified decoding time, then indicate, otherwise do not indicate *KVE+* Configuration Range Unit Default Setting...
6: Symbology Settings 6-3-10 TruncateEnding 6-3-10 TruncateEnding To set up the number of digits to be omitted from the end of the barcode *EUS+* Configuration Range Default Setting Procedure: (A) Scan “Enter” barcode (B) Scan “TruncateEnding” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“...
6: Symbology Settings 6-4-7 ISBN Conversion 6-4-7 ISBN Conversion If the barcode meets ”ISBN” regulation, whether to convert the scanning result to ISBN coding *JVV0* Disable *JVV1* Enable 6-4-8 Wait Addon Time 6-4-8 Wait Addon Time Wait for decoding additional code, need to use ” Wait Add-on”; If to get the additional code in a specified decoding time, then indicate, otherwise do not indicate *KVE+* Configuration Range...
6: Symbology Settings 6-4-9 TruncateLeading 6-4-9 TruncateLeading To set up the number of digits to be omitted from the beginning of the barcode *O1C+* Configuration Range Default Setting 0~13 Procedure: (A) Scan “Enter” barcode (B) Scan “TruncateLeading” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“...
6: Symbology Settings 6-4-11 TruncateZero 6-4-11 TruncateZero Whether to omit 0 from the beginning of the barcode *J1G0* Disable *J1G1* Enable 6-4-12 Insertion1DataPosition 6-4-12 Insertion1DataPosition To set up the position to insert data1 *L1I+* Configuration Range Default Setting 0~13 Procedure: (A) Scan “Enter”...
6: Symbology Settings 6-5-7 Wait Addon Time 6-5-7 Wait Addon Time Wait for decoding additional code, need to use” Wait Add-on” ; If to get the additional code in a specified decoding time, then indicate, otherwise do not indicate *KVE+* Configuration Range Unit Default Setting...
6: Symbology Settings 6-5-9 TruncateEnding 6-5-9 TruncateEnding To set up the number of digits to be omitted from the end of the barcode *9UE+* Configuration Range Default Setting Procedure: (A) Scan “Enter” barcode (B) Scan “TruncateEnding” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“...
6: Symbology Settings 6-6 Msi 6-6 Msi 6-6-1 Read 6-6-1 Read Whether the barcode can be scanned. *IW20* Disable *IW21* Enable 6-6-2 Chksum Verification 6-6-2 Chksum Verification To set up the regulation of check digit, only barcode meet the regulation can be scanned *JW30* *JW31*...
6: Symbology Settings 6-6-3 Min Code Length 6-6-3 Min Code Length To set up the minimum length of the barcode, less than this length barcode cannot be scanned *KW4+* Configuration Range Default Setting 4~48 Procedure: (A) Scan “Enter” barcode (B) Scan “Min Code Length” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“...
6: Symbology Settings 6-6-5 TruncateLeading 6-6-5 TruncateLeading To set up the number of digits to be omitted from the beginning of the barcode *M2I+* Configuration Range Default Setting 0~48 Procedure: (A) Scan “Enter” barcode (B) Scan “TruncateLeading” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“...
6: Symbology Settings 6-6-7 TruncateZero 6-6-7 TruncateZero Whether to omit 0 from the beginning of the barcode *Q2M0* Disable *Q2M1* Enable 6-6-8 Insertion1DataPosition 6-6-8 Insertion1DataPosition To set up the position to insert data1 *J2O+* Configuration Range Default Setting 0~48 Procedure: (A) Scan “Enter”...
6: Symbology Settings 6-7-4 Expanded Min Code Length 6-7-4 Expanded Min Code Length To set up the minimum length of the barcode, less than this length barcode cannot be scanned *PW9+* Configuration Range Default Setting 4~74 Procedure: (A) Scan “Enter” barcode (B) Scan “Min Code Length”...
6: Symbology Settings 6-7-6 TruncateLeading 6-7-6 TruncateLeading To set up the number of digits to be omitted from the beginning of the barcode *O76+* *P7Y+* *M8C+* Gs1DataBar Gs1DataBar Limited Gs1DataBar Expanded Type Configuration Range Default Setting Gs1DataBar 0-2435 Gs1DataBar Limited 0-74 Gs1DataBar Expanded 0-74...
6: Symbology Settings 6-7-7 TruncateEnding 6-7-7 TruncateEnding To set up the number of digits to be omitted from the end of the barcode *Q78+* *J80+* *O8E+* Gs1DataBar Gs1DataBar Limited Gs1DataBar Expanded Type Configuration Range Default Setting Gs1DataBar 0-2435 Gs1DataBar Limited 0-74 Gs1DataBar Expanded 0-74...
6: Symbology Settings 6-8 Gs1 Composite -8 Gs1 Composite 6-8-1 Read 6-8-1 Read Whether the barcode can be scanned. *IX10* Disable *IX11* Enable 6-8-2 Upc/EanVersion 6-8-2 Upc/EanVersion Scan the UPC/EAN Version on bar code to decode GS1 Composite symbols that have a U.P.C.
6: Symbology Settings 6-8-3 Gs1Emulation 6-8-3 Gs1Emulation The scanner can automatically format the output from GS1 data carrier to emulate what would be encoded in an equivalent GS1-128 or GS1 Databar cmbol. Gs1-128: It GS1-128 Emulation is scanned, all retail codes(U.P.C., UPC-E, EAN8, EAN13) are expanded out to 16 digits.
6: Symbology Settings 6-9-3 Min Code Length 6-9-3 Min Code Length To set up the minimum length of the barcode, less than this length barcode cannot be scanned *JWC+* *OWH+* CodablocA CodablocF Type Configuration Range Default Setting CodablocA 1~600 CodablocF 1~2048 Procedure: (A) Scan “Enter”...
6: Symbology Settings 6-9-5 TruncateLeading 6-9-5 TruncateLeading To set up the number of digits to be omitted from the beginning the barcode *EZE+* *I4U+* CodablocA CodablocF Type Configuration Range Default Setting CodablocA 0~600 CodablocF 0~2048 Procedure: (A) Scan “Enter” barcode (B) Scan “TruncateLeading”...
6: Symbology Settings 6-9-7 TruncateZero 6-9-7 TruncateZero Whether to omit 0 from the beginning of the barcode CodablocA CodablocF *9ZI0* *M4Y0* Disable Disable *9ZI1* *M4Y1* Enable Enable 6-9-8 Insertion1DataPosition 6-9-8 Insertion1DataPosition To set up the position to insert data1 *BZK+* *P50+* CodablocA CodablocF...
6: Symbology Settings 6-10 Pdf417 6-10 Pdf417 6-10-1 Pdf417 Read 6-10-1 Pdf417 Read Whether the barcode can be scanned *JWL0* Disable *JWL1* Enable 6-10-2 MacroPdf417 Read 6-10-2 MacroPdf417 Read MacroPDF417 is an implementation of PDF417 capable of encoding very large amounts of data into multiple PDF417 bar codes.
6: Symbology Settings 6-10-3 PoorQuality PDFCodes Read 6-10-3 PoorQuality PDFCodes Read This setting improves the scanner's ability to read damaged or badly printed PDF codes by combining information from multiple images. When Poor Quality PDF On is scanned, poor quality PDF code reading is improved, but the scanner's snappiness is decreased, making it less aggressive when reading good quality bar codes.
6: Symbology Settings 6-10-5 Min Code Length 6-10-5 Min Code Length To set up the minimum length of the barcode, less than this length barcode cannot be scanned *LWN+* *KWV+* Pdf417 MicroPdf417 Type Configuration Range Default Setting Pdf417 1~2750 MicroPdf417 1~366 Procedure: (A) Scan “Enter”...
6: Symbology Settings 6-10-7 TruncateLeading 6-10-7 TruncateLeading To set up the number of digits to be omitted from the beginning of the barcode *O58+* *CYM+* Pdf417 MicroPdf417 Type Configuration Range Default Setting Pdf417 0~2750 MicroPdf417 0~366 Procedure: (A) Scan “Enter” barcode (B) Scan “TruncateLeading”...
6: Symbology Settings 6-10-9 TruncateZero 6-10-9 TruncateZero Whether to omit 0 from the beginning of the barcode Pdf417 MicroPdf417 *J5C0* *GYQ0* Disable Disable *J5C1* *GYQ1* Enable Enable 6-10-10 Insertion1DataPosition 6-10-10 Insertion1DataPosition To set up the position to insert data1 *L5E+* *9YS+* Pdf417 MicroPdf417...
6: Symbology Settings 6-11 Tlc39 6-11 Tlc39 6-11-1 Read 6-11-1 Read Whether the barcode can be scanned *PX80* Disable *PX81* Enable 6-11-2 TruncateLeading 6-11-2 TruncateLeading To set up the number of digits to be omitted from the beginning of the barcode *9Z0+* Configuration Range Default Setting...
Page 127
6: Symbology Settings 6-11-3 TruncateEnding 6-11-3 TruncateEnding To set up the number of digits to be omitted from the end of the barcode *BZ2+* Configuration Range Default Setting 0~48 Procedure: (A) Scan “Enter” barcode (B) Scan “TruncateEnding” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“...
Page 128
6: Symbology Settings 6-11-5 Insertion1DataPosition 6-11-5 Insertion1DataPosition To set up the positon to insert data1 *FZ6+* Configuration Range Default Setting 0~48 Procedure: (A) Scan “Enter” barcode (B) Scan “Insertion1DataPosition” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“ barcode (E) Scan “End”...
Page 129
6: Symbology Settings 6-11-7 Insertion2DataPosition 6-11-7 Insertion2DataPosition To set up the position to insert data2 *AZA+* Configuration Range Default Setting 0~48 Procedure: (A) Scan “Enter” barcode (B) Scan “Insertion2DataPosition” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“ barcode (E) Scan “End”...
Page 130
6: Symbology Settings 6-12 QRCode 6-12 QRCode 6-12-1 Read 6-12-1 Read Whether the barcode can be scanned. *QX90* Disable *QX91* Enable 6-12-2 Min Code Length 6-12-2 Min Code Length To set up the minimum length of the barcode, less than this length barcode cannot be scanned *IXA+* Configuration Range...
Page 131
6: Symbology Settings 6-12-3 Max Code Length 6-12-3 Max Code Length To set up the maximum length of the barcode, longer than this length barcode cannot be scanned *KXC+* Configuration Range Default Setting 1~7089 7089 Procedure: (A) Scan “Enter” barcode (B) Scan “Max Code Length”...
Page 132
6: Symbology Settings 6-12-5 TruncateEnding 6-12-5 TruncateEnding To set up the number of digits to be omitted from the end of the barcode *M5O+* Configuration Range Default Setting 0~7089 Procedure: (A) Scan “Enter” barcode (B) Scan “TruncateEnding” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“...
Page 133
6: Symbology Settings 6-12-7 Insertion1DataPosition 6-12-7 Insertion1DataPosition To set up the position to insert data1 *Q5S+* Configuration Range Default Setting 0~7089 Procedure: (A) Scan “Enter” barcode (B) Scan “Insertion1DataPosition” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“ barcode (E) Scan “End”...
Page 134
6: Symbology Settings 6-12-9 Insertion2DataPosition 6-12-9 Insertion2DataPosition To set up the position to insert data2 *L5W+* Configuration Range Default Setting 0~7089 Procedure: (A) Scan “Enter” barcode (B) Scan “Insertion2DataPosition” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“ barcode (E) Scan “End”...
Page 135
6: Symbology Settings 6-13 DataMatrix 6-13 DataMatrix 6-13-1 Read 6-13-1 Read Whether the barcode can be scanned *OXG0* Disable *OXG1* Enable 6-13-2 Min Code Length 6-13-2 Min Code Length To set up the minimum length of the barcode, less than this length barcode cannot be scanned *PXH+* Configuration Range...
Page 136
6: Symbology Settings 6-13-3 Max Code Length 6-13-3 Max Code Length To set up the maximum length of the barcode, longer than this length barcode cannot be scanned *IXJ+* Configuration Range Default Setting 1~3116 3116 Procedure: (A) Scan “Enter” barcode (B) Scan “Max Code Length”...
Page 137
6: Symbology Settings 6-13-5 TruncateEnding 6-13-5 TruncateEnding To set up the number of digits to be omitted from the end of the barcode *O6G+* Configuration Range Default Setting 0~3116 Procedure: (A) Scan “Enter” barcode (B) Scan “TruncateEnding” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“...
Page 138
6: Symbology Settings 6-13-7 Insertion1DataPosition 6-13-7 Insertion1DataPosition To set up the position to insert data1 *J6K+* Configuration Range Default Setting 0~3116 Procedure: (A) Scan “Enter” barcode (B) Scan “Insertion1DataPosition” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“ barcode (E) Scan “End”...
Page 139
6: Symbology Settings 6-13-9 Insertion2DataPosition 6-13-9 Insertion2DataPosition To set up the position to insert data2 *N6O+* Configuration Range Default Setting 0~3116 Procedure: (A) Scan “Enter” barcode (B) Scan “Insertion2DataPosition” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“ barcode (E) Scan “End”...
Page 140
6: Symbology Settings 6-14 MaxiCode 6-14 MaxiCode 6-14-1 Read 6-14-1 Read Whether the barcode can be scanned *LXM0* Disable *LXM1* Enable 6-14-2 Min Code Length 6-14-2 Min Code Length To set up the minimum length of the barcode, less than this length barcode cannot be scanned *MXN+* Configuration Range...
Page 141
6: Symbology Settings 6-14-3 Max Code Length 6-14-3 Max Code Length To set up the maximum length of the barcode, longer than this length barcode cannot be scanned *NXO+* Configuration Range Default Setting 1~150 Procedure: (A) Scan “Enter” barcode (B) Scan “Max Code Length” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“...
Page 142
6: Symbology Settings 6-14-5 TruncateEnding 6-14-5 TruncateEnding To set up the number of digits to be omitted from the end of the barcode *K6U+* Configuration Range Default Setting 0~150 Procedure: (A) Scan “Enter” barcode (B) Scan “TruncateEnding” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“...
Page 143
6: Symbology Settings 6-14-7 Insertion1DataPosition 6-14-7 Insertion1DataPosition To set up the position to insert data1 *O6Y+* Configuration Range Default Setting 0~150 Procedure: (A) Scan “Enter” barcode (B) Scan “Insertion1DataPosition” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“ barcode (E) Scan “End”...
Page 144
6: Symbology Settings 6-14-9 Insertion2DataPosition 6-14-9 Insertion2DataPosition To set up the position to insert data2 *K72+* Configuration Range Default Setting 0~150 Procedure: (A) Scan “Enter” barcode (B) Scan “Insertion2DataPosition” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“ barcode (E) Scan “End”...
Page 145
6: Symbology Settings 6-15 Aztec 6-15 Aztec 6-15-1 Read 6-15-1 Read Whether the barcode can be scanned *OXP0* Disable *OXP1* Enable 6-15-2 Append 6-15-2 Append To set up whether able to scan multiple related barcodes, and decode them into a complete Aztec barcode Off: Disable this function On: Enable this function ;...
Page 146
6: Symbology Settings 6-15-3 Min Code Length 6-15-3 Min Code Length To set up the minimum length of the barcode, less than this length barcode cannot be scanned *PXQ+* Configuration Range Default Setting 1~3832 Procedure: (A) Scan “Enter” barcode (B) Scan “Min Code Length” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“...
Page 147
6: Symbology Settings 6-15-5 TruncateLeading 6-15-5 TruncateLeading To set up the number of digits to be omitted from the beginning of the barcode *K7K+* Configuration Range Default Setting 0~3832 Procedure: (A) Scan “Enter” barcode (B) Scan “TruncateLeading” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“...
Page 148
6: Symbology Settings 6-15-7 TruncateZero 6-15-7 TruncateZero Whether to omit 0 from the beginning of the barcode *O7O0* Disable *O7O1* Enable 6-15-8 Insertion1DataPosition 6-15-8 Insertion1DataPosition To set up the position to insert data1 *Q7Q+* Configuration Range Default Setting 0~3832 Procedure: (A) Scan “Enter”...
Page 149
6: Symbology Settings 6-15-9 Insertion1Data 6-15-9 Insertion1Data To set up data1 to be inserted *J7S+* Configuration Length Default Setting NULL Procedure: (A) Scan “Enter” barcode (B) Scan “Insertion1Data” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“ barcode (E) Scan “End”...
Page 150
6: Symbology Settings 6-15-11 Insertion2Data 6-15-11 Insertion2Data To set up data2 to be inserted *N7W+* Configuration Length Default Setting NULL Procedure: (A) Scan “Enter” barcode (B) Scan “Insertion2Data” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“ barcode (E) Scan “End”...
Page 151
6: Symbology Settings 6-16 ChineseSensible(HanXinCode) 6-16 ChineseSensible(HanXinCode) 6-16-1 Read 6-16-1 Read Whether the barcode can be scanned *NXX0* Disable *NXX1* Enable 6-16-2 Min Code Length 6-16-2 Min Code Length To set up the minimum length of the barcode, less than this length barcode cannot be scanned *OXY+* Configuration Range...
Page 152
6: Symbology Settings 6-16-3 Max Code Length 6-16-3 Max Code Length To set up the maximum length of the barcode, longer than this length barcode cannot be scanned *IY0+* Configuration Range Default Setting 1~7833 7833 Procedure: (A) Scan “Enter” barcode (B) Scan “Max Code Length”...
Page 153
6: Symbology Settings 6-16-5 TruncateEnding 6-16-5 TruncateEnding To set up the number of digits to be omitted from the end of the barcode *BV6+* Configuration Range Default Setting 0~7833 Procedure: (A) Scan “Enter” barcode (B) Scan “TruncateEnding” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“...
Page 154
6: Symbology Settings 6-16-7 Insertion1DataPosition 6-16-7 Insertion1DataPosition To set up the position to insert data1 *FVA+* Configuration Range Default Setting 0~7833 Procedure: (A) Scan “Enter” barcode (B) Scan “Insertion1DataPosition” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“ barcode (E) Scan “End”...
Page 155
6: Symbology Settings 6-16-9 Insertion2DataPosition 6-16-9 Insertion2DataPosition To set up the position to insert data2 *AVE+* Configuration Range Default Setting 0~7833 Procedure: (A) Scan “Enter” barcode (B) Scan “Insertion2DataPosition” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“ barcode (E) Scan “End”...
Page 156
6: Symbology Settings 6-17 Codabar(Nw7) 6-17 Codabar (Nw7) 6-17-1 Read 6-17-1 Read Whether the barcode can be scanned *KY20* Disable *KY21* Enable 6-17-2 Start/End Transmission 6-17-2 Start/End Transmission Whether to send the start code and end code of the barcode *LY30* Disable *LY31*...
Page 157
6: Symbology Settings 6-17-3 Chksum Digit 6-17-3 Chksum Digit To set up the regulation of check digit, and whether to send the check digit *MY40* Disable *MY41* Modulo 16 *MY42* Modulo 16,Transmit 6-17-4 Concatenation 6-17-4 Concatenation Codabar supports symbol concatenation. When you enable concatenation, the scanner looks for a Codabar symbol having a “D”...
Page 158
6: Symbology Settings 6-17-5 Min Code Length 6-17-5 Min Code Length To set up the minimum length of the barcode, less than this length barcode cannot be scanned *OY6+* Configuration Range Default Setting 2~60 Procedure: (A) Scan “Enter” barcode (B) Scan “Min Code Length” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“...
Page 159
6: Symbology Settings 6-17-7 DblConFirm 6-17-7 DblConFirm To decode the barcode multiple times. If the result of each decoding is the same, it means that the barcode decoding is successful *QY8+* Configuration Range Default Setting 0~10 Procedure: (A) Scan “Enter” barcode (B) Scan “DblConFirm”...
Page 160
6: Symbology Settings 6-17-9 TruncateLeading 6-17-9 TruncateLeading To set up the number of digits to be omitted from the beginning of the barcode *Q06+* Configuration Range Default Setting 0~60 Procedure: (A) Scan “Enter” barcode (B) Scan “TruncateLeading” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“...
Page 161
6: Symbology Settings 6-17-11 TruncateZero 6-17-11 TruncateZero Whether to omit 0 from the beginning of the barcode *L0A0* Disable *L0A1* Enable 6-17-12 Insertion1DataPosition 6-17-12 Insertion1DataPosition To set up the position to insert data1 *N0C+* Configuration Range Default Setting 0~60 Procedure: (A) Scan “Enter”...
Page 162
6: Symbology Settings 6-17-13 Insertion1Data 6-17-13 Insertion1Data To set up the data1 to be inserted *P0E+* Configuration Length Default Setting NULL Procedure: (A) Scan “Enter” barcode (B) Scan “Insertion1Data” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“ barcode (E) Scan “End”...
Page 163
6: Symbology Settings 6-17-15 Insertion2Data 6-17-15 Insertion2Data To set up the data2 to be inserted *K0I+* Configuration Length Default Setting NULL Procedure: (A) Scan “Enter” barcode (B) Scan “Insertion2Data” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“ barcode (E) Scan “End”...
Page 164
6: Symbology Settings 6-18 Code39 6-18 Code39 6-18-1 Read 6-18-1 Read Whether the barcode can be scanned *DC00* Disable *DC01* Enable 6-18-2 Chksum Verification 6-18-2 Chksum Verification To set up the regulation of check digit, and whether to send the check digit *FC20* Disable *FC21*...
Page 165
6: Symbology Settings 6-18-3 Start/End Transmission 6-18-3 Start/End Transmission Whether to indicate ”*” in the beginning and the end of the barcode *EC10* Disable *EC11* Enable 6-18-4 Type 6-18-4 Type To set up whether able to decode the Code39 of Full ASCII, to indicate lowercase and special symbologies *GC30* Standard...
Page 166
6: Symbology Settings 6-18-5 Min Code Length 6-18-5 Min Code Length To set up the minimum length of the barcode, less than this length barcode cannot be scanned *HC4+* Configuration Range Default Setting 0~48 Procedure: (A) Scan “Enter” barcode (B) Scan “Min Code Length” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“...
Page 167
6: Symbology Settings 6-18-7 DblConFirm 6-18-7 DblConFirm To decode the barcode multiple times. If the result of each decoding is the same, it means that the barcode decoding is successful *BC7+* Configuration Range Default Setting 0~10 Procedure: (A) Scan “Enter” barcode (B) Scan “DblConFirm”...
Page 168
6: Symbology Settings 6-18-9 TruncateLeading 6-18-9 TruncateLeading To set up the number of digits to be omitted from the beginning of the barcode *M0K+* *GSE+* Code39 Code32 Type Configuration Range Default Setting Code39 0~48 Code32 0~48 Procedure: (A) Scan “Enter” barcode (B) Scan “TruncateLeading”...
Page 169
6: Symbology Settings 6-18-11 TruncateZero 6-18-11 TruncateZero Whether to omit 0 from the beginning of the barcode Code39 Code32 *Q0O0* *BSI0* Disable Disable *Q0O1* *BSI1* Enable Enable 6-18-12 Insertion1DataPosition 6-18-12 Insertion1DataPosition To set up the position to insert data1 *J0Q+* *DSK+* Code39 Code32...
Page 170
6: Symbology Settings 6-18-13 Insertion1Data 6-18-13 Insertion1Data To set up data1 to be inserted *L0S+* *FSM+* Code39 Code32 Type Configuration Length Default Setting Code39 NULL Code32 NULL Procedure: (A) Scan “Enter” barcode (B) Scan “Insertion1Data” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“...
Page 171
6: Symbology Settings 6-18-15 Insertion2Data 6-18-15 Insertion2Data To set up data2 to be inserted *P0W+* *ASQ+* Code39 Code32 Type Configuration Length Default Setting Code39 NULL Code32 NULL Procedure: (A) Scan “Enter” barcode (B) Scan “Insertion2Data” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“...
Page 172
6: Symbology Settings 6-19 Interleaved2of5 6-19 Interleaved2of5 6-19-1 Read 6-19-1 Read Whether the barcode can be scanned *OYO0* Disable *OYO1* Enable 6-19-2 Chksum Digit 6-19-2 Chksum Digit To set up the regulation of check digit, and whether to send the check digit *PYP0* Disable *PYP1*...
Page 173
6: Symbology Settings 6-19-3 Min Code Length 6-19-3 Min Code Length To set up the minimum length of the barcode, less than this length barcode cannot be scanned *QYQ+* Configuration Range Default Setting 2~80 Procedure: (A) Scan “Enter” barcode (B) Scan “Min Code Length” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“...
Page 174
6: Symbology Settings 6-19-5 TruncateLeading 6-19-5 TruncateLeading To set up the number of digits to be omitted from the beginning of the barcode *K1Q+* Configuration Range Default Setting 0~80 Procedure: (A) Scan “Enter” barcode (B) Scan “TruncateLeading” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“...
Page 175
6: Symbology Settings 6-19-7 TruncateZero 6-19-7 TruncateZero Whether to omit 0 from the beginning of the barcode *O1U0* Disable *O1U1* Enable 6-19-8 Insertion1DataPosition 6-19-8 Insertion1DataPosition To set up the position to insert data1 *Q1W+* Configuration Range Default Setting 0~80 Procedure: (A) Scan “Enter”...
Page 176
6: Symbology Settings 6-19-9 Insertion1Data 6-19-9 Insertion1Data To set up data1 to be inserted *J1Y+* Configuration Length Default Setting NULL Procedure: (A) Scan “Enter” barcode (B) Scan “Insertion1Data” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“ barcode (E) Scan “End”...
Page 177
6: Symbology Settings 6-19-11 Insertion2Data 6-19-11 Insertion2Data To set up the data2 to be inserted *O22+* Configuration Length Default Setting NULL Procedure: (A) Scan “Enter” barcode (B) Scan “Insertion2Data” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“ barcode (E) Scan “End”...
Page 178
6: Symbology Settings 6-20 Nec2of5 6-20 Nec2of5 6-20-1 Read 6-20-1 Read Whether the barcode can be scanned *KYT0* Disable *KYT1* Enable 6-20-2 Chksum Digit 6-20-2 Chksum Digit To set up the regulation of check digit, and whether to send the check digit *LYU0* Disable *LYU1*...
Page 179
6: Symbology Settings 6-20-3 Min Code Length 6-20-3 Min Code Length To set up the minimum length of the barcode, less than this length barcode cannot be scanned *MYV+* Configuration Range Default Setting 2~80 Procedure: (A) Scan “Enter” barcode (B) Scan “Min Code Length” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“...
Page 180
6: Symbology Settings 6-20-5 TruncateLeading 6-20-5 TruncateLeading To set up the number of digits to be omitted from the beginning of the barcode *AZS+* Configuration Range Default Setting 0~80 Procedure: (A) Scan “Enter” barcode (B) Scan “TruncateLeading” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“...
Page 181
6: Symbology Settings 6-20-7 TruncateZero 6-20-7 TruncateZero Whether to omit 0 from the beginning of the barcode *EZW0* Disable *EZW1* Enable 6-20-8 Insertion1DataPosition 6-20-8 Insertion1DataPosition To set up the position to insert data1 *GZY+* Configuration Range Default Setting 0~80 Procedure: (A) Scan “Enter”...
Page 182
6: Symbology Settings 6-20-9 Insertion1Data 6-20-9 Insertion1Data To set up data1 to be inserted *K00+* Configuration Length Default Setting NULL Procedure: (A) Scan “Enter” barcode (B) Scan “Insertion1Data” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“ barcode (E) Scan “End”...
Page 183
6: Symbology Settings 6-20-11 Insertion2Data 6-20-11 Insertion2Data To set up data2 to be inserted *O04+* Configuration Length Default Setting NULL Procedure: (A) Scan “Enter” barcode (B) Scan “Insertion2Data” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“ barcode (E) Scan “End”...
Page 184
6: Symbology Settings 6-21 Code93 6-21 Code93 6-21-1 Read 6-21-1 Read Whether the barcode can be scanned *OYX0* Disable *OYX1* Enable 6-21-2 Append 6-21-2 Append To set up whether able to scan multiple related barcodes, and decode them in to a complete Code93 barcode *KZ10* Disable...
Page 185
6: Symbology Settings 6-21-3 Min Code Length 6-21-3 Min Code Length To set up the minimum length of the barcode, less than this length barcode cannot be scanned *PYY+* Configuration Range Default Setting 0~80 Procedure: (A) Scan “Enter” barcode (B) Scan “Min Code Length” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“...
Page 186
6: Symbology Settings 6-21-5 TruncateLeading 6-21-5 TruncateLeading To set up the number of digits to be omitted from the beginning the barcode *O3A+* Configuration Range Default Setting 0~80 Procedure: (A) Scan “Enter” barcode (B) Scan “TruncateLeading” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“...
Page 187
6: Symbology Settings 6-21-7 TruncateZero 6-21-7 TruncateZero Whether to omit 0 from the beginning of the barcode *J3E0* Disable *J3E1* Enable 6-21-8 Insertion1DataPosition 6-21-8 Insertion1DataPosition To set up the position to insert data1 *L3G+* Configuration Range Default Setting 0~80 Procedure: (A) Scan “Enter”...
Page 188
6: Symbology Settings 6-21-9 Insertion1Data 6-21-9 Insertion1Data To set up data1 to be insert *N3I+* Configuration Length Default Setting NULL Procedure: (A) Scan “Enter” barcode (B) Scan “Insertion1Data” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“ barcode (E) Scan “End”...
Page 189
6: Symbology Settings 6-21-11 Insertion2Data 6-21-11 Insertion2Data To set up data2 to be inserted *I3M+* Configuration Length Default Setting NULL Procedure: (A) Scan “Enter” barcode (B) Scan “Insertion2Data” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“ barcode (E) Scan “End”...
Page 190
6: Symbology Settings 6-22 Straight2of5 (Industrial2of5) 6-22 Straight2of5 (Industrial2of5) 6-22-1 Read 6-22-1 Read Whether the barcode can be scanned Straight2of5 Straight2of5IATA *LZ20* *OZ50* Disable Disable *LZ21* *OZ51* Enable Enable 6-22-2 Min Code Length 6-22-2 Min Code Length To set up the minimum length of the barcode, less than this length barcode cannot be scanned *MZ3+* *PZ6+*...
Page 191
6: Symbology Settings 6-22-3 Max Code Length 6-22-3 Max Code Length To set up the maximum length of the barcode, longer than this length barcode cannot be scanned *NZ4+* *QZ7+* Straight2of5 Straight2of5IATA Type Configuration Range Default Setting Straight2of5 1~48 Straight2of5IATA 1~48 Procedure: (A) Scan “Enter”...
Page 192
6: Symbology Settings 6-22-5 TruncateLeading 6-22-5 TruncateLeading To set up the number of digits to be omitted from the beginning of the barcode *Q24+* Configuration Range Default Setting 0~48 Procedure: (A) Scan “Enter” barcode (B) Scan “TruncateLeading” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“...
Page 193
6: Symbology Settings 6-22-7 TruncateZero 6-22-7 TruncateZero Whether to omit 0 from the beginning of the barcode *L280* Disable *L281* Enable 6-22-8 Insertion1DataPosition 6-22-8 Insertion1DataPosition To set up the position to insert data1 *N2A+* Configuration Range Default Setting 0~48 Procedure: (A) Scan “Enter”...
Page 194
6: Symbology Settings 6-22-9 Insertion1Data 6-22-9 Insertion1Data To set up data1 to be inserted *P2C+* Configuration Length Default Setting NULL Procedure: (A) Scan “Enter” barcode (B) Scan “Insertion1Data” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“ barcode (E) Scan “End”...
Page 195
6: Symbology Settings 6-22-11 Insertion2Data Insertion2Data 6-22-11 To set up data2 to be inserted *K2G+* Configuration Length Default Setting NULL Procedure: (A) Scan “Enter” barcode (B) Scan “Insertion2Data” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“ barcode (E) Scan “End”...
Page 196
6: Symbology Settings 6-23 Matrix2of5 6-23 Matrix2of5 6-23-1 Read 6-23-1 Read Whether the barcode can be scanned *JZ90* Disable *JZ91* Enable 6-23-2 Min Code Length 6-23-2 Min Code Length To set up the minimum length of the barcode, less than this length barcode cannot be scanned *KZA+* Configuration Range...
Page 197
6: Symbology Settings 6-23-3 Max Code Length 6-23-3 Max Code Length To set up the maximum length of the barcode, longer than this length barcode cannot be scanned *LZB+* Configuration Range Default Setting 1~80 Procedure: (A) Scan “Enter” barcode (B) Scan “Max Code Length” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“...
Page 198
6: Symbology Settings 6-23-5 TruncateEnding 6-23-5 TruncateEnding To set up the number of digit to be omitted from the end of the barcode *O4I+* Configuration Range Default Setting 0~80 Procedure: (A) Scan “Enter” barcode (B) Scan “TruncateEnding” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“...
Page 199
6: Symbology Settings 6-23-7 Insertion1DataPosition 6-23-7 Insertion1DataPosition To set up the position to insert data1 *J4M+* Configuration Range Default Setting 0~80 Procedure: (A) Scan “Enter” barcode (B) Scan “Insertion1DataPosition” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“ barcode (E) Scan “End”...
Page 200
6: Symbology Settings 6-23-9 Insertion2DataPosition 6-23-9 Insertion2DataPosition To set up the position to insert data2 *N4Q+* Configuration Range Default Setting 0~80 Procedure: (A) Scan “Enter” barcode (B) Scan “Insertion2DataPosition” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“ barcode (E) Scan “End”...
Page 201
6: Symbology Settings 6-24 Code11 6-24 Code11 6-24-1 Read 6-24-1 Read Whether the barcode can be scanned *MZC0* Disable *MZC1* Enable 6-24-2 Chksum Digit 6-24-2 Chksum Digit To choose how many digits to use for the check digit. *PZF0* 1Checkdigit *PZF1* 2Checkdigit Enter...
Page 202
6: Symbology Settings 6-24-3 Min Code Length 6-24-3 Min Code Length To set up the minimum length of the barcode, less than this length barcode cannot be scanned *NZD+* Configuration Range Default Setting 1~80 Procedure: (A) Scan “Enter” barcode (B) Scan “Min Code Length” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“...
6: Symbology Settings 6-24-5 TruncateLeading 6-24-5 TruncateLeading To set up the number of digits to be omitted from the beginning of the barcode *I2W+* Configuration Range Default Setting 0~80 Procedure: (A) Scan “Enter” barcode (B) Scan “TruncateLeading” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“...
6: Symbology Settings 6-24-7 TruncateZero 6-24-7 TruncateZero Whether to omit 0 from the beginning of the barcode *N300* Disable *N301* Enable 6-24-8 Insertion1DataPosition 6-24-8 Insertion1DataPosition To set up the position to insert data1 *P32+* Configuration Range Default Setting 0~80 Procedure: (A) Scan “Enter”...
6: Symbology Settings 6-25 Code128 6-25 Code128 6-25-1 Read 6-25-1 Read Whether the barcode can be scanned *QZG0* Disable *QZG1* Enable 6-25-2 Append 6-25-2 Append To set up whether able to scan multiple related barcodes, and decode them into a complete Code128 barcode *MZL0* Disable...
6: Symbology Settings 6-25-3 ISBTConcatenation 6-25-3 ISBTConcatenation Whether able to read ISBT128 barcode *NZM0* Disable *NZM1* Enable 6-25-4 Min Code Length 6-25-4 Min Code Length To set up the minimum length of the barcode, less than this length barcode cannot be scanned *IZH+* Configuration Range...
6: Symbology Settings 6-25-5 Max Code Length 6-25-5 Max Code Length To set up the maximum length of the barcode, longer than this length barcode cannot be scanned *JZI+* Configuration Range Default Setting 0~80 Procedure: (A) Scan “Enter” barcode (B) Scan “Max Code Length” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“...
6: Symbology Settings 6-25-7 TruncateEnding 6-25-7 TruncateEnding To set up the number of digits to be omitted from the end of the barcode *M3Q+* Configuration Range Default Setting 0~80 Procedure: (A) Scan “Enter” barcode (B) Scan “TruncateEnding” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“...
6: Symbology Settings 6-26 Gs1-128 6-26 Gs1-128 6-26-1 Read 6-26-1 Read Whether the barcode can be scanned *OZN0* Disable *OZN1* Enable 6-26-2 Min Code Length 6-26-2 Min Code Length To set up the minimum length of the barcode, less than this length barcode cannot be scanned *PZO+* Configuration Range...
6: Symbology Settings 6-26-3 Max Code Length 6-26-3 Max Code Length To set up the maximum length of the barcode, longer than this length barcode cannot be scanned *QZP+* Configuration Range Default Setting 0~80 Procedure: (A) Scan “Enter” barcode (B) Scan “Max Code Length” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“...
6: Symbology Settings 6-26-5 TruncateEnding 6-26-5 TruncateEnding To set up the number of digits to be omitted from the end of the barcode *GVK+* Configuration Range Default Setting 0~80 Procedure: (A) Scan “Enter” barcode (B) Scan “TruncateEnding” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“...
6: Symbology Settings 6-27 2D Postal 6-27 2D Postal 6-27-1 Read 6-27-1 Read To set up the 2D Postal barcode can be scanned *IZQ0* *IZQ1* *IZQ2* AustralianPost InfoMail *IZQ3* *IZQ4* *IZQ5* JapanesePost KIXPost(NetherlandsPost) PlanetCode(PLA) *IZQ6* *IZQ7* *IZQ8* Postnet(POS) BritishPost InfoMail/BritishPost *IZQ9* *IZQA* *IZQB*...
6: Symbology Settings 6-27-4 AustralianPostInterpretation 6-27-4 AustralianPostInterpretation This option controls what interpretation is applied to customer fields in Australian 4-State symbols BarOutput: Bar Output lists the bar patterns in “0123” format NumericN: Numeric N Table causes that field to be interpreted as numeric data using the N Table AlphanumericC: Alphanumeric C Table causes the field to be interpreted as alphanumeric data using the C Table.
6: Symbology Settings 6-27-5 TruncateLeading 6-27-5 TruncateLeading To set up the number of digits to be omitted from the beginning of the barcode *9T6+* *BS0+* *AVW+* AustralianPost InfoMail JapanesePost *CWO+* *AXU+* *ETK+* PlanetCode Postnet BritishPost *EXG+* *9X2+* *ATY+* Postal4i IntelligentMail CanadianPost *GWA+* NetherlandsPost...
6: Symbology Settings 6-27-6 TruncateEnding 6-27-6 TruncateEnding To set up the number of digits to be omitted from the end of the barcode *BT8+* *DS2+* *CVY+* AustralianPost InfoMail JapanesePost *EWQ+* *CXW+* *GTM+* PlanetCode Postnet BritishPost *GXI+* *BX4+* *DU0+* Postal4i IntelligentMail CanadianPost *9WC+* NetherlandsPost...
6: Symbology Settings 6-27-9 Insertion1Data 6-27-9 Insertion1Data To set up data1 to be inserted *HTE+* *AS8+* *AW4+* AustralianPost InfoMail JapanesePost *BWW+* *AY2+* *DTS+* PlanetCode Postnet BritishPost *DXO+* *HXA+* *AU6+* Postal4i IntelligentMail CanadianPost *FWI+* NetherlandsPost Type Configuration Length Default Setting AustralianPost NULL InfoMail NULL...
Page 226
6: Symbology Settings 6-27-10 Insertion2DataPosition Insertion2DataPosition 6-27-10 To set up the position to insert data2 *ATG+* *CSA+* *CW6+* AustralianPost InfoMail JapanesePost *DWY+* *CY4+* *FTU+* PlanetCode Postnet BritishPost *FXQ+* *AXC+* *CU8+* Postal4i IntelligentMail CanadianPost *HWK+* NetherlandsPost Type Configuration Range Default Setting AustralianPost 0~80 InfoMail...
Page 227
6: Symbology Settings Insertion2Data 6-27-11 6-27-11 Insertion2Data To set up data2 to be inserted *CTI+* *ESC+* *EW8+* AustralianPost InfoMail JapanesePost *GX0+* *EY6+* *HTW+* PlanetCode Postnet BritishPost *HXS+* *CXE+* *EUA+* Postal4i IntelligentMail CanadianPost *AWM+* NetherlandsPost Type Configuration Length Default Setting AustralianPost NULL InfoMail NULL...
Page 228
6: Symbology Settings 6-28 ChinaPost (HongKong2of5) 6-28 ChinaPost (HongKong2of5) 6-28-1 Read 6-28-1 Read Whether the barcode can be scanned *PZX0* Disable *PZX1* Enable 6-28-2 Min Code Length 6-28-2 Min Code Length To set up the minimum length of the barcode, less than this length barcode cannot be scanned *QZY+* Configuration Range...
Page 229
6: Symbology Settings 6-28-3 Max Code Length 6-28-3 Max Code Length To set up the maximum length of the barcode, longer than this length barcode cannot be scanned *IZZ+* Configuration Range Default Setting 2~80 Procedure: (A) Scan “Enter” barcode (B) Scan “Max Code Length” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“...
Page 230
6: Symbology Settings 6-28-5 TruncateEnding 6-28-5 TruncateEnding To set up the number of digits to be omitted from the end of the barcode *9YA+* Configuration Range Default Setting 0~80 Procedure: (A) Scan “Enter” barcode (B) Scan “TruncateEnding” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“...
Page 231
6: Symbology Settings 6-28-7 Insertion1DataPosition 6-28-7 Insertion1DataPosition To set up the position to insert data1 *DYE+* Configuration Range Default Setting 0~80 Procedure: (A) Scan “Enter” barcode (B) Scan “Insertion1DataPosition” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“ barcode (E) Scan “End”...
Page 232
6: Symbology Settings 6-28-9 Insertion2DataPosition 6-28-9 Insertion2DataPosition To set up the position to insert data2 *HYI+* Configuration Range Default Setting 0~80 Procedure: (A) Scan “Enter” barcode (B) Scan “Insertion2DataPosition” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“ barcode (E) Scan “End”...
Page 233
6: Symbology Settings 6-29 KoreaPost 6-29 KoreaPost 6-29-1 Read 6-29-1 Read Whether the barcode can be scanned *U000* Disable *U001* Enable 6-29-2 Tx Checkdigit 6-29-2 Tx Checkdigit Whether to send check digit *X030* Disable *X031* Enable Enter */$%ENTR* *ZEND*...
Page 234
6: Symbology Settings 6-29-3 Min Code Length 6-29-3 Min Code Length To set up the minimum length of the barcode, less than this length barcode cannot be scanned *V01+* Configuration Range Default Setting 2~80 Procedure: (A) Scan “Enter” barcode (B) Scan “Min Code Length” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“...
Page 235
6: Symbology Settings 6-29-5 TruncateLeading 6-29-5 TruncateLeading To set up the number of digits to be omitted from the beginning of the barcode *CSS+* Configuration Range Default Setting 0~80 Procedure: (A) Scan “Enter” barcode (B) Scan “TruncateLeading” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“...
Page 236
6: Symbology Settings 6-29-7 TruncateZero 6-29-7 TruncateZero Whether to omit 0 from the beginning of the barcode *GSW0* Disable *GSW1* Enable 6-29-8 Insertion1DataPosition 6-29-8 Insertion1DataPosition To set up the position to insert data1 *9SY+* Configuration Range Default Setting 0~80 Procedure: (A) Scan “Enter”...
Page 237
6: Symbology Settings 6-29-9 Insertion1Data 6-29-9 Insertion1Data To set up data1 to be inserted *CT0+* Configuration Length Default Setting NULL Procedure: (A) Scan “Enter” barcode (B) Scan “Insertion1Data” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“ barcode (E) Scan “End”...
Page 238
6: Symbology Settings 6-29-11 Insertion2Data 6-29-11 Insertion2Data To set up data2 to be inserted *GT4+* Configuration Length Default Setting NULL Procedure: (A) Scan “Enter” barcode (B) Scan “Insertion2Data” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“ barcode (E) Scan “End”...
Page 239
6: Symbology Settings 6-30 Telepen 6-30 Telepen 6-30-1 Read 6-30-1 Read Whether the barcode can be scanned *BQB0* Disable *BQB1* Enable 6-30-2 Output 6-29-2 Tx Checkdigit AIM: Using AIM Telepen output, the scanner reads symbol with start/stop pattern 1 and decodes them as standard full ASCII(start/stop pattern 1). Original: When Original Telepen Output is selected, the scanner reads symbols with start/stop pattern 1 and decodes them as compressed numeric with optional full ASCII (start/stop pattern 2)
Page 240
6: Symbology Settings 6-30-3 Min Code Length 6-30-3 Min Code Length To set up the minimum length of the barcode, less than this length barcode cannot be scanned *DQD+* Configuration Range Default Setting 1~60 Procedure: (A) Scan “Enter” barcode (B) Scan “Min Code Length” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“...
Page 241
6: Symbology Settings 6-30-5 TruncateLeading 6-30-5 TruncateLeading To set up the number of digits to be omitted from the beginning of the barcode *Q60+* Configuration Range Default Setting 0~60 Procedure: (A) Scan “Enter” barcode (B) Scan “TruncateLeading” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“...
Page 242
6: Symbology Settings 6-30-7 TruncateZero 6-30-7 TruncateZero Whether to omit 0 from the beginning of the barcode *L640* Disable *L641* Enable 6-30-8 Insertion1DataPosition 6-30-8 Insertion1DataPosition To set up the position to insert data1 *N66+* Configuration Range Default Setting 0~60 Procedure: (A) Scan “Enter”...
Page 243
6: Symbology Settings 6-30-9 Insertion1Data 6-30-9 Insertion1Data To set up data1 to be inserted *P68+* Configuration Length Default Setting NULL Procedure: (A) Scan “Enter” barcode (B) Scan “Insertion1Data” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“ barcode (E) Scan “End”...
Page 244
6: Symbology Settings 6-30-11 Insertion2Data 6-30-11 Insertion2Data To set up data2 to be inserted *K6C+* Configuration Length Default Setting NULL Procedure: (A) Scan “Enter” barcode (B) Scan “Insertion2Data” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“ barcode (E) Scan “End”...
Page 245
6: Symbology Settings 6-31 GS1AppID & FNC1 6-31 GS1AppID & FNC1 6-31-1 AppIDSw 6-31-1 AppIDSw Whether AppID will be delimit by Conchar in GS1 code. *BCG0* Disable *BCG1* Enable 6-31-1 AppIDConChar 6-31-2 AppIDConChar The Conchar will be assigned to delimit AppID. *CCH+* Configuration Length Default Setting...
Page 246
6: Symbology Settings 6-31-3 FNC1Sw 6-31-3 FNC1Sw Whether to display the content of FNC1. *DCI0* Disable *DCI1* Enable 6-31-4 FNC1Char 6-31-4 FNC1Char To set the content of FNC1. *ECJ+* Configuration Length Default Setting 0x1D Procedure: (A) Scan “Enter” barcode (B) Scan “FNC1Char” barcode (C) Scan parameters from Hexadecimal / Decimal table (D) Scan “OK“...
Page 249
6: Symbology Settings 6-32-2 BarcodeID Setting 6-32-2 BarcodeID Setting This page is for setting Barcode ID. When”Tx CodeId Tx CodeId”is set as ”Enable Enable”, the Tx CodeId Tx CodeId Enable Enable barcode ID will be indicated according to the setting position by ” Code Position Code Position”...