OSYPKA PACE 203H User Notes
Hide thumbs Also See for PACE 203H:

Advertisement

Quick Links

User Notes PACE 203H

Displays, Dials and Keys

ATRIUM
INDIFF(+) DIFF(-)
UPPER
DISPLAY
A-SENSE
A-STIM.
V-STIM.
V-SENSE
LOWER
DISPLAY

Display Symbols

OFF
BATTERY (FULL CHARGED)
INTERFERENCE (ATRIUM / VENTRICLE)
OPEN LEAD (ATRIUM / VENTRICLE)
EXTRASYSTOLE (PVC)
ALARMS DISABLED
ACOUSTIC INDICATOR ENABLED
LOCKED / UNLOCKED
These User Notes do not replace the Instruction for Use (IfU).
Read the IfU carefully before using the product.
VENTRICLE
INDIFF(+) DIFF(-)
BASIC RATE
A-SENSITIVITY
A-AMPLITUDE
A-V DELAY
V-AMPLITUDE
V-SENSITIVITY
EMERGENCY
STIMULATION
UNLOCKING/
LOCKING
STIM. PAUSE
SOFTKEYS
ON
(menu keys)
Osypka Medical
5I-17-017X-B-18 P1
User Notes PACE 203H
VENTRICLE
DIFF(-) INDIFF(+) DIFF(-) INDIFF(+)
HANGER
BUTTON COVER
Hanger snaps in two positions for hanging up or standing up the
device.
The battery release button opens the battery compartment.
A button cover protects the battery release button.
These User Notes do not replace the Instruction for Use (IfU).
Read the IfU carefully before using the product.
Rear Side
ATRIUM
CTRL.OUT
5I-17-017X-B-18 P2
Osypka Medical

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PACE 203H and is the answer not in the manual?

Questions and answers

Summary of Contents for OSYPKA PACE 203H

  • Page 1 User Notes PACE 203H User Notes PACE 203H Displays, Dials and Keys Rear Side ATRIUM VENTRICLE VENTRICLE ATRIUM INDIFF(+) DIFF(-) INDIFF(+) DIFF(-) DIFF(-) INDIFF(+) DIFF(-) INDIFF(+) UPPER DISPLAY BASIC RATE A-SENSITIVITY A-SENSE A-AMPLITUDE A-STIM. A-V DELAY HANGER V-AMPLITUDE V-STIM. V-SENSITIVITY...
  • Page 2 In order to prevent an accidental change of parameters, the The connector plug must not be touched with bare hands or come PACE 203H is locked automatically, if no dial has been rotated in contact with electrically conductive or wet surfaces.
  • Page 3 V00 VVI VAT Using the Automatic Functions Main Menu • If the related automatic function are enabled, the PACE 203H Setting D00, V00, A00 automatically adjusts A-V delay (AVD), PVARP and maximum • First select "primary" pacing mode (see above), tracking rate (MTR) with setting of the basic rate.
  • Page 4 • Set basic rate 10 ppm below the patient's intrinsic rate. • In case the PACE 203H is operating in a dual chamber mode, • In a dual chamber mode, the A-V delay must be set to a value the A-V delay must be set to a value less than the patient’s own...
  • Page 5 With the pause function the determination • of sensitivity threshold and intrinsic rate can be simplified The Atrial High-Rate Standby Menu appears. But the PACE 203H still continues operation in the set mode. considerably. • START Press and hold the Pause key.
  • Page 6 User Notes PACE 203H User Notes PACE 203H Adjustment of Pacer Timing Parameters Setting Options • Press softkeys Main Menu, Parameters/Options and Options PVARP & MTR in this order. The post ventricular atrial refractory period (PVARP) and the • The Options Menu consists of two parts. First the left one maximum tracking rate (MTR) can be adjusted automatically with appears.
  • Page 7 (the rightmost triangular one) is blinking and the text • Care and cleaning of the PACE 203H and of the accessories message "Change battery!" appears in the lower display. During a shall be done according to instruction of use.