Download Print this page
Frigidaire FFHT1425PWH Service Data Sheet

Frigidaire FFHT1425PWH Service Data Sheet

Advertisement

Quick Links

PERFORMANCE DATA
NO LOAD & NO DOOR OPENINGS AT MID-POINT CONTROL SETTING
Type A With Run/
70°F (21.1°C)
Start Capacitor
Ambient
Operating Time
26 to 29%
Freezer Temperature
5° to -2.2°F
(-15° to -19°C)
Refrigerator Temperature
35° to 40°F
(2° to 4°C)
Low Side Pressure
-3.24 to 0.80 psig
(cut-in)
( 79 to 107 kPa)
Low Side Pressure
-6.70 to -6.19 psig
(cut-out)
(55 to 59 kPa)
High Side Pressure
38 to 39 psig
(last 1/3 cycle)
(364 to 372 kPa)
Wattage (last 1/3 cycle)
68 W
Amps (running)
0.6 to 0.8 A
Base Voltage
115 V
Refrigerant Charge
1.58 oz. (45 g)
DEFROST SPECIFICATIONS
Thermal Fuse
Cabinet Size: 14'
Cut-out
161.6°F
(72°C)
EVAPORATOR FAN MOTOR
Watts
RPM
3.1 (max)
2700 CW
ICE MAKER SPECIFICATIONS
Electrical
115 vac (127 vac max)
ICE MAKER CONNECTOR PLUG CONNECTIONS
Wire Number
Wire Color
1
Light Blue
2
Yellow
3
Black
Turn the IM ON and OFF: Press and hold the POWER button for ½ second to turn the IM ON and OFF. When the IM is ON, the Power button will be illuminated solid green
Test Cycling: Press and release the TEST/SERVICEbutton to start the self-diagnostic function. The tray will perform two rotations. The ice level arm must be held so that it does not drop during the first rotation (simulating full ice bin). Once the
tray returns to the Home position, the arm can be released. Allow the arm to drop normally during the the second rotation (simulating empty ice bin). Once the tray returns Home after the second rotation, the POWER button will change back to
solid green if no errors were detected during the test. This means the IM operates properly. If errors are detected at any time during the test, the test will stop immediately and the POWER button will blink rapidly continuously. In this case, there
is some internal failure of the IM. NOTE: If the arm is not held during the first rotation, the IM will indicate a failure falsely. To run the test again to verify, the IM must be turned OFF and back ON.
Manual Water Fill: Press and hold the TEST/SERVICE button for 3+ seconds.
Adjust Water Fill Size: Press and hold the POWER and TEST/SERVICE buttons together for 3 seconds. The POWER button will blink to show the current setting.
1 blink = small, 2 blinks = med, 3 blinks = large, 4 blinks = extra large. Press the TEST/SERVICE button to advance to the next level. When at extra large, the next press goes back to small. The factory default is small.
90°F (32°C)
Ambient
45 to 47%
5° to -2.2°F
(-15° to -19°C)
IMPORTANT SAFETY NOTE
35° to 40°F
The information provided herein is designed to assist qualified repair personnel only.
(2° to 4°C)
Untrained persons should not attempt to make repairs due to the possibility of electrical
shock. Disconnect power cord before servicing this appliance.
-3.24 to -0.66 psig
IMPORTANT
(79 to 97 kPa)
If any green grounding wires are removed during servicing, they must be returned to
-6.59 to -6.22 psig
their original position and properly secured.
(56 to 58 kPa)
57 to 58 psig
(498 to 503 kPa)
CAUTION
68 W
All electrical parts and wiring must be shielded from torch flame. DO NOT
0.6 to 0.8 A
allow torch to touch insulation; it will char at 200°F and flash ignite (burn) at
500°F. Excessive heat will distort the plastic liner.
115 V
Defrost
Unit will complete normal defrost cycle.
Heater
Thermistor
enter
Watts
Ohms
Termination
exit
48°F
166
79.7
(8.89°C)
Defrost is terminated when defrost thermistor located on the evaporator coil reaches
48°F (8.89°C).
Amps
0.258 Running
IMPORTANT
START-UP NOTE: Upon 1st start-up or power cycle, the compressor will
60 Hertz
come on after 15 seconds and run for 4 minutes. If the door switch is not
cycled during this time, the compressor may cut off after 4 minutes and not
turn back on for another 3 minutes. It may take up to 10 minutes for the
Connects to:
compressor to turn on and run in normal mode.
Neutral
Water Valve
Line
SERVICE DATA SHEET
A17276301
STANDARD - AUTOMATIC DEFROST
TOP MOUNT FREEZER - R600a
MANUAL DEFROST
--> Press the FF door switch 5 times in 2 secs.
--> Cycle power to the unit or enter and exit
SERVICE MODE. (See SERVICE MODE)
ICE MAKER INFORMATION
IMPORTANT
PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION.
SERVICE MODE
SERVICE MODE will step through available tests to diagnose individual electrical cir-
cuits. Fresh Food compartment light will be OFF while in SERVICE MODE.
--> Press the door switch 3 times and hold the 4th press until
enter/exit
the FF light turns on. When switch is released the light should
turn off. The door switch must be pressed 4 times in 2 seconds.
initiate first/
--> Press the door switch 2 times.
next test
1
Compressor
Press the FF door switch twice to start the first test. In each
test, the component listed will be powered on. The compo-
2
Heater
nent will stay powered until the next test is activated, or until
3
FF Light
5 minutes of inactivity expire. Listen for operating sounds;
feel for heat or air flow, as appropriate, to determine the
result of each test. Press the FF door switch twice again to
4
Evaporator Fan
advance between tests.
Service Mode
Normal Cooling
Mode
Press Door Switch 3
Press Door Switch
Times and Hold 4th Press Until
2 Times
the FF Light Turns On
Test 1:
Compressor ON
Press Door Switch
To Exit Service Mode from
2 Times
Enters Service
any Test Press Door Switch
Mode
Press Door Switch
3 Times and Hold 4th Press
2 Times
Manual Defrost
Test 4: Evaporator
Press Door Switch 5 Times to
Fan ON
Enter Manual Defrost. POR
Press Door Switch
2 Times
or Enter Service Mode to Exit
Manual Defrost.
108 mm
Test 2: Power ON
to Defrost Heater
Press Door Switch
2 Times
Test 3: Fresh
Food Light ON

Advertisement

loading

Summary of Contents for Frigidaire FFHT1425PWH

  • Page 1 SERVICE DATA SHEET IMPORTANT PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT MID-POINT CONTROL SETTING A17276301 PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION. Type A With Run/ 70°F (21.1°C) 90°F (32°C) STANDARD - AUTOMATIC DEFROST Start Capacitor Ambient Ambient TOP MOUNT FREEZER - R600a SERVICE MODE...