Page 1
Jackson WWS, Inc. P.O. Box 1060 Barbourville, KY 40906 888-800-5672 INSTRUCTIONS FOR TEMPSTAR DRAIN QUENCH KIT WARNING: • This kit should be installed only by qualified service personnel to reduce the risk of electric shock, serious injury or fire. A plumbing permit and the services of a licensed plumber and electrician may be required in some areas.
Page 2
Assembly 05700-004-14-95 INDEX DESCRIPTION PART NUMBER SOLENOID VALVE, ¼, 240V 04810-002-31-09 NIPPLE, ¼ CLOSE BRASS 04730-207-02-00 NIPPLE, ¼ NPT X 3 (BRASS) 04730-004-08-07 REDUCER, ½ X ¼ BRASS 04730-003-62-16 VALVE, CHECK ½ 04820-002-55-77 NIPPLE, ½ CLOSE BRASS 04730-207-15-00 REDUCER, 1-1/2 X ½ HEX BRASS 04730-002-55-75 Assembly 05700-004-14-98 INDEX...
Miscellaneous Parts INDEX DESCRIPTION PART NUMBER TEE, 1-1/2 BRASS 04730-011-69-93 ELBOW, 1-1/2 NPT, FEMALE 04730-206-32-00 WASH HEATER COVER 05700-004-07-92 CONDUIT FITTING, 45°-1/2” 05975-011-45-23 LIQUID TIGHT FITTING (LARGE) 05975-011-65-51 CONNECTOR (PIGGY BACK ) 05940-200-42-00...
Page 4
208-230V: Attach terminals to input side of the motor contactor L1/L2, lower terminals. Refer to step 16. black wire red wire 460V: Connect to the Constant Voltage Connection (fused terminal board). Refer to step 17. L2: Red L1:Gray Wire. Wire. White wire Black wire connects to...
Page 5
2. Drain wash tank. 3. Remove front dress panel from dish machine. Refer to picture below. 4. Install assembly 05700-004-14-96 (as shown) into the wash tank discharge. NOTE: Pipe thread sealant tape must be applied to all plumbing components upon installation.
Page 6
Refer to photo below. (Solenoid coil may need to be removed before attaching assembly to tee.) 7. Connect the drain discharge piping (not supplied by Jackson) to the 1-1/2” tee (index #1). Refer to the picture below. A 1-1/2” street elbow has been supplied if needed to...
Page 7
8. Connect COLD WATER supply to solenoid valve. A ¼” nipple (index #6) is supplied to make that connection if needed. The picture below shows the connection point. 9. Remove the wash tank heater cover. Use a 3/8” nut driver or wrench to remove the two nuts from the cover, they are located at the top and on the bottom of the cover.
Page 8
11. Place bracket (assembly 05700-004-14-98) over studs and reinstall the two nuts and lockwashers removed on step 16. 12. Remove nut and ferrule from ¼” compression fitting attached to assembly 05700-004- 14-96. Attach nut and ferrule to thermostat probe. Insert probe into ¼” compression fitting (index #4).
Page 9
13. Remove the control box cover. Use a phillps screwdriver to remove the four screws (two on each side). CAUTION: Ensure power is off. 14. On the back of the control box remove the black plug and replace it with liquid tight fitting(index #21).
Page 10
17. FOR 460V UNITS ONLY! Locate Constant Voltage Connection and pull terminals L1 (gray wire) and L2 (red wire) from fuse holders. Place one piggyback terminal (index #22) on L1 and one on L2 and reconnect them to the Constant Voltage Connection fuse holders. Connect black wire from sj cord on the L1 piggyback terminal.
Page 11
19. Attach coil to solenoid. Use phillps screw driver to tighten screw. NOTE: COIL WILL COME ASSEMBLED WITH 45° CONDUIT FITTING (INDEX #20), CONDUIT AND WIRING. COIL 20. Connect conduit from coil to 90° conduit fitting (index #15) attached to bracket. Both the red and white wires from the conduit must come though the fitting.
Page 12
23. Install new wash tank heater cover (index #19) using hardware removed in step 13. 24. Replace front dress panel. Restore power and water to machine. Run the machine through five cycles to ensure that there are no leaks. If there are any issues after installation please contact: JACKSON WWS TECHNICAL SERVICE 1-888-800-5672...