Adler Power CO-SinusUPS-400W-WM User Manual

Adler Power CO-SinusUPS-400W-WM User Manual

Pure sine wave inverter ups

Advertisement

Available languages

Available languages

Quick Links

6. S
PECIFICATION
Model
Output Power
Input Voltage / Frequency
Output Voltage Range (AC mode)
Output Voltage and Frequency (Battery mode)
Transfer Time
Battery Voltage
Charging Current
Output Waveform (Battery mode)
Operation Temperature and Humidity
Dimensions
Net Weight
7. F
P
RONT
ANEL
Voltage Display
Battery
Capacity
indicator
8. B
ACK VIEW
Breaker
Input AC wire
INPUT
BREAKER
220V~,50Hz
250V~,4.5A
Cooling Fan
CO-SinusUPS-400W-WM
500VA / 400W
147 ÷ 275VAC ± 5VAC; 47 65Hz
÷
190 ÷ 255VAC ± 5VAC
210 ÷ 235VAC / 50Hz
max. 10ms
12VDC
max. 5A
Pure Sine Wave
0 ÷ 40°C, 10 ÷ 90%
260 x 267 x 113mm
5.8kg
Cooling Fan
Indicator
AC input
Auto
Buzzer/Mute*
Voltage Display
Turn ON
Battery Mode
AC Mode
Indicator
Indicator
*In overload condition and for low battery
can't mute the UPS
Battery positive wire
OUTPUT
External battery
12V
Battery negative wire
AC output socket (2pcs.)
4
PURE SINE WAVE INVERTER UPS
CO-SinusUPS-400W-WM
MODEL:
A
PPLICATIONS
AC output
off-grid solar systems, home electronics, WI-FI,
Load Level
Indicator
BAT+
This manual is an important instruction that you should follow during
Installation and maintenance of the inverter. Please read all instructions
before using the equipment and save this document for future reference.
BAT-
CO-sinusUPS-400W-WM-manual-R3, 20.03.10
:
C
heating and hot water systems,
ENTRAL
yachts, campers, etc.
U
M
SER
ANUAL
Please read and save this manual!
1

Advertisement

loading

Summary of Contents for Adler Power CO-SinusUPS-400W-WM

  • Page 1 INPUT BREAKER 220V~,50Hz 250V~,4.5A installation and maintenance of the inverter. Please read all instructions OUTPUT before using the equipment and save this document for future reference. External battery Battery negative wire BAT- Cooling Fan AC output socket (2pcs.) CO-sinusUPS-400W-WM-manual-R3, 20.03.10...
  • Page 2 1. INSTALLATION 4. TROUBLESHOOTING Problem Possible Causes Action to take 1. Put the UPS in ventilated area, kept it away from water, combustible and corrosive gas. Keep UPS upright and all the vent holes on panels opened. The utility power is normal, but the UPS UPS input breaker 2.
  • Page 3 INPUT BREAKER 220V~,50Hz 250V~,4.5A instalacji i użytkowania urządzenia. Zapoznaj się z zawartymi w niej informacjami OUTPUT przed uruchomieniem urządzenia i zachowaj niniejszą instrukcję do wykorzystania w przyszłości. External battery Ujemny zacisk wejściowy akmulatora BAT- Wentylator Gniazda wyjściowe (2szt.) CO-sinusUPS-400W-WM-manual-R3, 20.03.10...
  • Page 4 1. M 4. R ONTAŻ OZWIĄZYWANIE PROBLEMÓW 1. Umieść UPS w wentylowanym pomieszczeniu, trzymaj go z dala od wody, łatwopalnego i żrącego gazu. Zamontuj UPS Problem Możliwe przyczyny Czynności do wykonania pionowo tak aby nie zasłaniać otworów wentylacyjnych. 2. W przypadku przeniesienia UPS z gorącej do zimnej przestrzeni nastąpi kondensacja pary, należy upewnić się, że UPS jest Podczas obecności zasilania sieciowego, Rozłącznik w UPS jest Podłącz z powrotem rozłącznik.