Technische specificaties | Technical specifications
Wattage | Power
Voltage
Dimbaar | Dimmable
Kleur | Colour
Kleurtemperatuur | Color temperature
Stralingshoek | Beam angle
Gemid. levensduur | Expected life time
Afmetingen | Dimensions W x H
Batterij| Battery
Batterij bescherming | Battery protection
Autonomie | Autonomy
Indicatie LED | Indication LED
Test knop | Test button
IP klasse | IP class
Veiligheidsinstructies
Laat dit product installeren en onderhouden door een erkend installateur.
De beschikbare netspanning mag niet hoger zijn dan de spanning in de specificaties
van deze handleiding.
Houd dit product buiten het bereik van kinderen en onbevoegden.
Elektrocutiegevaar bij het openen van het product. Raak geen kabels aan die onder
stroom staan om dodelijke elektrische schokken te vermijden. Open de behuizing niet
zelf. Laat het onderhoud van het product over aan een erkend installateur.
Dit verlichtingsproduct heeft geen ingebouwde voorziening om het los te koppelen
van het stroomnet. Isoleer het product elektrisch voor de installatie of onderhoud.
Zorg ervoor dat het stroomsnoer niet gekneld of geplooid is en bescherm het tegen
beschadigingen. Waarschuwing! Indien de voedingskabel beschadigd is, dan moet
deze door de fabrikant, diens servicedienst, of een gelijkwaardig bekwaam persoon
vervangen worden om gevaar te voorkomen.
Attentie: mogelijk gevaarlijke optische straling uitgezonden door dit product. Kijk nooit
rechtstreeks in de lichtbron. Dit kan leiden tot oogletsel.
Attentie: dit product wordt warm tijdens het gebruik.
Gebruik het product enkel binnenshuis. Bescherm het product tegen regen,
vochtigheid en opspattende vloeistoffen. Plaats geen objecten gevuld met vloeistof
op of naast het product.
Gebruik het armatuur niet indien de beschermplaat / cover gebarsten of gebroken is.
Ontkoppel het product onmiddellijk. De beschermplaat / cover is niet vervangbaar.
Alle elektrotechnische installaties dienen te worden uitgevoerd volgens de IEE
bedradingsrichtlijnen.
Reiniging en onderhoud
Dit verlichtingsproduct heeft geen ingebouwde voorziening om het los te koppelen
van het stroomnet. Isoleer het product elektrisch voor de installatie of onderhoud.
Alle gebruikte schroeven moeten goed zijn aangespannen en mogen geen sporen
van roest vertonen.
De behuizing, de zichtbare delen, de montagebeugels en de montageplaats (bv. het
plafond of bevestingsveren) mogen niet vervormd zijn of aangepast worden (geen
extra gaten in montagebeugels boren, aansluitingen niet verplaatsen, enz.).
Mechanisch bewegende delen mogen geen sporen van slijtage vertonen en mogen
niet onregelmatig bewegen.
De voedingskabels mogen niet beschadigd zijn. Laat het product onderhouden door
een erkend installateur.
Indien de beschermplaat / cover beschadigd is, moet u het product onmiddellijk
loskoppelen van het stroomnet. Gebruik het product niet indien de beschermplaat /
cover gebarsten of gebroken is. De beschermplaat / cover is niet vervangbaar.
De gebruiker mag geen onderdelen vervangen.
Bestel eventuele reserveonderdelen bij uw plaatselijke verdeler.
Maak het product geregeld schoon met een vochtige, niet pluizende doek.
Gebruik geen alcohol of oplosmiddelen voor de reiniging.
Test de verlichting en de accu periodiek, conform landelijke en/of Europese
richtlijnen.
®
IP20
Opbouw Hangend Noodverlichtingsarmatuur 3W
x D (H
)
310 x 230 x 35 mm (70 mm)
1
2
4,8V 600mAh Ni-Cd accu
over charge / discharge
94000114
3 W
220-240 VAC
no
day light
6000 °K
120°
36000 hours
3 hours
yes
yes
IP20
Safety instructions
A qualified technician shall install and service this device.
Make sure that the available voltage does not exceed the voltage stated in the
specifications of this manual.
Keep this device away from children and unauthorized users.
Risk of electroshock when opening the cover. Touching live wires can cause life-
threatening electroshocks. Do not disassemble or open the housing yourself. Have the
device repaired by qualified personnel.
This luminaire does not have a built-in device to disconnect it from the electric mains.
Make sure to electrically isolate the luminaire before installation or maintenance
activities are performed. Do not crimp the power cord and protect it against
damage. Warning! If the power cord is damaged, it must be replaced by the
manufacturer, its service agent, or similarly qualified persons in order to avoid any
hazard.
Caution: possibly hazardous optical radiation emitted from this product. Do not look
at operating lamp. Eye injury may result.
Caution: device heats up during use.
Indoor use only. Keep this device away from rain, moisture, splashing and dripping
liquids. Never put objects filled with liquids on top of or close to the device.
Do not use the luminaire with a cracked or broken protective shield. Disconnect
immediately from the mains. The protective shield is not replaceable.
All electrical installations must be carried out according to IEE wiring regulations.
Cleaning and maintenance
This luminaire does not have a built-in device to disconnect it from the electric mains.
Make sure to electrically isolate the luminaire before installation or maintenance
activities are performed.
All screws shall be tight and free of corrosion.
The housing, the visible parts, the mounting supports and the installation location
(e.g. ceiling, suspension, etc.) shall not be deformed, modified or tampered with;
e.g. do not drill extra holes in mounting supports, do not change the location of the
connections.
Mechanically moving parts must not show any signs of wear and tear.
The electric power supply cables must not show any damage.
Have a qualified technician maintain the device.
If the protective shield / cover is damaged, disconnect the lamp immediately from
the mains. Do not use the lamp with a cracked or broken protective shield / cover.
The protective shield / cover is not replaceable.
There are no user-serviceable parts.
Contact your dealer for spare parts if necessary.
Wipe the device regularly with a moist, lint-free cloth.
Do not use alcohol or solvents for cleaning.
Test the lighting and the battery periodically, in accordance with national and / or
European regulations.
D
W
H
2
H
1
Versie 2018.11

Advertisement

loading

Summary of Contents for DecaLED 94000114

  • Page 1 DecaLED ® Emergency Range Opbouw Hangend Noodverlichtingsarmatuur 3W www.decaled.com Product code(s) 94000114 RoHS IP20 Technische specificaties | Technical specifications Opbouw Hangend Noodverlichtingsarmatuur 3W 94000114 Wattage | Power Voltage 220-240 VAC Dimbaar | Dimmable Kleur | Colour day light Kleurtemperatuur | Color temperature 6000 °K...
  • Page 2 Make sure the printed side of the pictogram is installed inwards against the hanging gekeerd gemonteerd is. plate. Algemeen gebruik General usage Het DecaLED Opbouw Hang Noodverlichtingsarmatuur 3W kan worden ingezet als ® vluchtwegindicatie / vluchtroute aanduiding. Dit LED armatuur wordt geleverd inclusief The DecaLED Hanging Escape Route luminaire 3W can be used as escape route ®...