ou should affix the hood to a wall of sufficient weight-bearing capacity, so not to one
made of plasterboard.
T
he cooker hood must be placed at a minimum distance of 65 cm from the cooking
plane for electric cookers and 65cm for gas or mixed cookers. If the instructions for
installation for the gas hob specify a greater distance, this has to be taken into account.
Do not tile, grout or silicone this appliance to the wall. Surface mounting only. Do not
fix c himney fl ue to furniture or fly ove r she lves unl ess the chi mney flue can be e asi ly
removed, in case maintenance is ever required.
T
he cooker hood is provided with an upper air exit B for discharging fumes externally
for models including chimney flue C ( Suction Version A- exhaust pipe not supplied). If
cooking fumes and vapours cannot be externally discharged, the cooker hood can be
used in the recirculating version F: the installation of 1 active charcoal filter F allows the
recirculation of fumes and vapours through the upper grid G.
M
ake sure that there is a power socket near the hood and that the system has a 30 mA
differential. The mains voltage must be the same as that on the label inside the hood. The
hood has a 1250 mm power cable with or without plug: if it does have a plug, connect
the hood to an accessible approved socket; or if it does not (connection direct to the
mains), fit an approved bipolar switch with a minimum contact opening of no less than
3 mm (accessible). This installation and electrical connection must be executed by a
qualified technician.
I
f the cooking top is in use, the cooker hood must always operate.
P
roduct performance test carried out in accordance with standard (EU) No 65/2014-
Ref: IEC 61591
Maximum performance is achieved by placing the mobile panels, if any, in the open
position.
WARNINGS
5