6. TROUBLESHOOTING
PROBLEM
Rivet jammed.
no suction.
Air leaking.
Tool runs slow or suffers a loss of
power.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: no liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
CAUSE
Wrong size rivet/nozzle.
Filings jammed in jaw housing.
Filings jammed in nozzle.
The shut-off valve has not been opened.
Damaged o-rings.
Loose screws.
Air line is loose.
Exhaust port is blocked.
operating pressure is too low.
Sole UK Distributor, Sealey Group,
Kempson Way, Suffolk Business Park,
Bury St. Edmunds, Suffolk,
IP32 7AR
Original Language Version
REMEDY
use the correct size nozzle for the rivet
Snap off rivet head, dismantle jaw housing and pull
out the rivet mandrel. use an airline to blow out the
filings, oil and re-assemble the jaw housing.
Clean out the nozzle.
open shut-off valve.
o-rings must be replaced.
Tighten screws.
Re-install and tighten airline.
Clean out exhaust port.
Increase the operating pressure to 85-95psi.
If the pressure exceeds 105-110psi, the safety valve
will operate.