Do you have a question about the KI 025 Series and is the answer not in the manual?
Questions and answers
Subscribe to Our Youtube Channel
Summary of Contents for Kingfisher KI 025 Series
Page 1
KI 025 Series Optical Talk Set OPERATING & MAINTENANCE GUIDE...
Page 2
The product was tested in a typical configuration with Kingfisher International test systems. 2005-July-20 Bruce Robertson Date Name Technical Director Title For further information, please contact your local Kingfisher International sales office, agent or distributor. Revision: C Issue Date: 2005- July-20 KI 025 UM-5...
Contents Service & Support Care of your Instrument Introduction Specifications General Safety Summary Ordering Information Optical Connector Maintenance Battery & External Power Quick Reference Guide Performance Verification Tests Discalimer & Warranty Getting Started & Turning On Notes KI 025 UM-5...
Page 5
Figure 1 KI 025DD Optical Talk Set KI 025 UM-5...
Please visit www.kingfisher.com.au to see our comprehensive www.kingfisher.com.au ). Application Notes, written to support our instrument users. Kingfisher offers a fixed price repair service, to avoid delays and Our local agents are able to offer excellent applications advice in minimise disruption for our customers.
Introduction The KI 025 Series Optical Talk Set is designed to provide convenient In any mode, a buzzer can be used to call the remote unit. The full duplex voice communication on one optical fibre. same buzzer can be used as a 2 KHz source for fibre identifiers.
Kingfisher International assumes no instrument both mechanically and electrically. liability for the customer’s failure to comply with these requirements.
Page 9
General Safety Summary Safety Laser & LED Safety Information These instruments contain no hazardous optical or electrical items. Laser Fabry-Perot Semiconductor Laser The following information is for your reference: λ 1550 nm When using this equipment, optical safety precautions should be Max CW output power¹...
Page 10
Figure 2 KI 025DD Fibre Optic Talk Set KI 025 UM-5...
Optical Connector To install a through adaptor, align the locating slot on the side of the How to clean the optical connectors through adaptor with that on the instrument connector, and press it Always clean the mating connector tip and ferrule before mating, using approved materials.
Battery & External Power This instrument is fitted with an internal rechargeable battery. For operation of the instrument by external power, use Kingfisher AC adaptor OPT103 (9V DC, 0.3 A,). Suitable external power packs are easily available, and must meet the following requirements: Rated for local mains supply voltage &...
Getting Started & Turning On Powering Up If the rocker switch is set in the mid position, you will be able to listen, but not transmit. In this mode, push the 'Manual' function to transmit. Check the compatibility of the supplied mains power unit with your This feature can be useful in very noisy situations, to avoid spurious mains power supply.
Page 15
Getting Started & Turning On It’s as simple as: Turn the unit on, and set the volume Plug in the fibre You can now receive calls or hear the buzzer Set transmit to auto or manual Speakerphone operation is now fully functional The buzzer is independent of all other controls If you want to use a headset –...
Page 16
Figure 3 KI 025DD Optical Talk Set, Internal View KI 025 UM-5...
Care of your Instrument Environmental Please note that the instrument is not waterproof, so exposure to liquids should be avoided if possible. The (optional) carry case is This equipment is ruggedly constructed with a cast aluminium frame, hose-proof and dustproof, and provides complete protection. which will take normal wear and tear.
Specifications Size: 190 / 120 / 95 mm (7.4" x 4.7" x 3.7”) Minimum Optical Range: 1 kg (2.2lb) Singlemode Multimode 1550nm Laser -50 dB -38 dB Carry Case: 280 / 330 / 150 mm (11" x 13" x 5.9") KI 025DD 1.9 kg (4.2lb) Headset:...
Page 19
Specifications Audio Quality: At normal headset sound level, S/N is 20 dB until optical loss is 10 dB less than specified maximum, where performance deteriorates. Receiver bandwidth: 500 Hz ~ 3.5 KHz Headset microphone bandwidth: 1.8 ~ 3.5 KHz Built-in microphone bandwidth: 500 Hz ~ 2 KHz Multiplex Operation: More than two units can be operated together.
Ordering Information Ordering Information: Optional Interchangeable Connector Adaptors: Instrument E2000/LSH, blue OPT060 OPT080 Optical Talk Set, PC connector KI 025DD E2000/LSH, green OPT060G OPT081 2.5 mm Universal Optical Talk Set, APC connector KI 025DD-APC LSA/DIN 47256 OPT071 SMA 905/906 OPT082 The above p/n is for one instrument.
Maintenance IMPORTANT: There are no user adjustable items internally. Other electronic malfunction would imply returning the unit to an authorised service READ THIS BEFORE OPENING AN INSTRUMENT centre. This equipment contains delicate and expensive fibre optic and CAUTION! optoelectronic components. DO NOT OPEN unless: Use of controls or adjustments or performance of procedures other You are authorised to do so;...
Page 22
Maintenance Opening the Instrument Re-assembly Read previous section before starting; This is the reverse of the previous section. Place the instrument face down on a bench, and remove the 6 Be particularly careful to: screws holding the baseplate to the instrument body. Do not Replace the cable ties;...
Page 23
50 mA charge current, or get a (side-by-side) battery pack with solder terminals. These can be obtained from Kingfisher. If you have bought 200 mA is the battery charger protection fuse; separate batteries, solder them in a ‘flat-four’ arrangement, and put 1 AMP is the battery protection fuse.
Page 24
Maintenance Changing the Operator Controls Open the unit as descibed in the section above, and completely separate the two instrument halves. Once this is done, changing individual item should be self-evident. Items are as follows: - Battery charger socket: CON013 Speaker, Mylar 50mm: MEC005 Headset:...
Quick Reference Guide 9V DC Battery Charger Loudspeaker Link 1 Output Port Link 2 Output Port Low Battery Tx Indicator Indicator Microphone Phone Jack On / Off / Microphone Call / Buzzer Volume Control Control SW KI 025 UM-5...
Fax: (61) 3 9757 4193 Information in this manual is given in good faith for the benefit of the user. It cannot be used as the basis for claims against Kingfisher E-mail: sales@kingfisher.com.au International or its representatives, if accidental damage or Website: http://www.kingfisher.com.au...
Need help?
Do you have a question about the KI 025 Series and is the answer not in the manual?
Questions and answers