INSTALLATION, OPERATING AND SERVICE MANUAL
ULTRAVIOLET DISINFECTION SYSTEM
7-LWT-UV410-009
PLEASE CAREFULLY READ INSTRUCTIONS BEFORE INSTALLING SYSTEM
FOLLOW ALL STATE AND LOCAL CODES AND REGULATIONS FOR PLUMBING AND ELECTRICAL.
INSTALLATION BY A CERTIFIED PLUMBER IS RECOMMENDED.
Congratulations on purchasing your new Lancaster Water UV Disinfection System. This unit is
designed to give you many years of trouble free service. For servicing and future inspection purposes,
please file this booklet with your important documents.
In the event that you need assistance for servicing your UV system, please first contact the
professional contractor who installed the system.
PAGE 1

Advertisement

Table of Contents
loading

Summary of Contents for Lancaster Clear-Flo Haloshield 7-LWT-UV410-009

  • Page 1 FOLLOW ALL STATE AND LOCAL CODES AND REGULATIONS FOR PLUMBING AND ELECTRICAL. INSTALLATION BY A CERTIFIED PLUMBER IS RECOMMENDED. Congratulations on purchasing your new Lancaster Water UV Disinfection System. This unit is designed to give you many years of trouble free service. For servicing and future inspection purposes, please file this booklet with your important documents.
  • Page 2: Safety Instructions

    PLEASE CAREFULLY READ INSTRUCTIONS BEFORE INSTALLING SYSTEM FOLLOW ALL STATE AND LOCAL CODES AND REGULATIONS FOR PLUMBING AND ELECTRICAL. INSTALLATION BY A CERTIFIED PLUMBER IS RECOMMENDED. Safety Instructions: DANGER Failure to follow these instructions will result in serious injury or death. •...
  • Page 3: Safety Information

    danger, warning, and caution statements in this manual. Failure to do so could result in serious personal injury or damage to the equipment. Make sure that the protection provided by this equipment is not impaired. DO NOT use or install this equipment in any Safety Information manner other than that specified in the installation manual.
  • Page 4 17-UV GROUND NUT 14-UV UV-MAN-1AP MANIFOLD ALUMINUM GLAND NUT FILTER HOUSING VENT-VALVE UV-100 MP STAINLESS STEEL UV CHAMBER FILTER HOUSING HEAD UV-ELL-1FM 410-C5-MB STAINLESS STEEL STREET ELBOW FILTER CARTRIDGE AND FM1-24 FLEXIBLE HOSE FILTER HOUSING O-RING 410-H-1-B BLUE FILTER HOUSING, INCLUDING PLUGGED HEAD, SUMP, O-RING FILTER HOUSING...
  • Page 5 ASSEMBLY: DETAIL A UV LAMP U - CLIP ALUMINUM GLAND NUT LAMP COMPRESSION SPRING GROUND NUT O - RING GFCI GROUND STUD PROTECTED CIRCUIT 120V QUARTZ SLEEVE MANIFOLD FILTER HOUSING VENT-VALVE STAINLESS STEEL UV CHAMBER BUSHING LAMP CONNECTOR BALLAST FILTER MOUNTING HOUSING HEAD SCREWS/...
  • Page 6 GENERAL NOTES FOR ESTIMATING ONLY. ALL DIMENSIONS ARE IN INCHES. WEIGHT: 22 LBS 21.00 11.25 9.00 4.50 16.00 4.50 OUTLET INLET 1.0 MNPT 20.44 1.0 FNPT DRAIN 0.5 MNPT PAGE 6...
  • Page 7: Specifications

    Contact LANCASTER WATER TREATMENT for references. (2) Models are supplied with a 5 FT. power cordset for 120V AC 60 Hz (NEMA 5-15P plug to IEC 60320/C13 connector).
  • Page 8: Installing Your Uv Disinfection System

    Installing your UV Disinfection System: CAUTION The electronic ballast must be connected to a Ground Fault Protected Circuit (GFCI) receptacle. Ensure the green ground wire ring terminal is securely fastened to the UV chamber ground stud using its ground nut. Ensure the green ground wire fork terminal is securely fastened to the electronic ballast using its ground screw.
  • Page 9 2. Select a suitable location for the disinfection system and its related components. As it is recommended to install a ground fault protected circuit (GFCI), make sure that this is taken into consideration prior to any installation. When selecting a mounting location, you must also leave enough space to allow for the removal of the UV lamp and/or quartz sleeve, as well as enough space to change out the filter cartridge.
  • Page 10: Disinfection Procedure

    Disinfection Procedure: UV disinfection is a physical disinfection process and does not add any potentially harmful chemicals to the water. As UV does not provide a disinfection residual, it is imperative that the entire distribution system located after the UV be chemically disinfected to ensure that the water is free from any bacteriological contaminants.
  • Page 11 inutes • Make sure vent is closed. • Turn on the cold water supply faucets • With valves closed, vent pressure and followed by hot water until you smell the remove sump housing using sump • Turn on water supply. bleach.
  • Page 12: Maintenance Instructions

    Maintenance Instructions: WARNING • Always disconnect power before performing any work on the disinfection system. • Always shut-off water flow and release water pressure before servicing. • Regularly inspect your disinfection system to ensure that the power indicators are on and no alarms are present.
  • Page 13: Filter Cartridge Replacement

    4. Remove the aluminum gland nut by turning counter clockwise. Place a small pail under the UV chamber to catch any water that may leak from the system. Grasp the quartz sleeve and fully remove from the UV chamber. Make sure the sealing o-ring is removed with the quartz sleeve.
  • Page 14 • Remove sump housing using the sump • Remove and discard the used filter • Open the new filter cartridge wrap spanner wrench. cartridge in accordance with applicable and discard wrap. Insert the new filter codes and regulations. Wipe clean the cartridge into the sump housing and Note: Be careful as it will be full of water sump housing with cold water and a soft...
  • Page 15 (ballast total running days continues counting). The audible alarm cannot be disinfection. Use only Lancaster Water Treatment lamps to ensure proper operation and performance. silenced. Please note that if this condition occurs and you are on a non-municipal water source, you should immediately stop using the water for potable applications until the lamp is replaced and distribution lines are disinfected.
  • Page 16: Troubleshooting Guide

    Reset, following GFCI manufacturer’s instructions Blank GFCI wall socket is tripped • Check socket with other applications 11/19 A DIVISION OF C-B TOOL CO. 1340 MANHEIM PIKE ● LANCASTER PA 17601-3196 ● TEL:717-397-3521 ● FAX: 717-392-0266 PAGE 16 www.lancasterwatertreatment.com ● E-mail: info@lancasterpump.com...