Fit-out instructions IWS-03F..
Before you start installing read the complete manual first
C
ross reference this manual also with the IWS-03 manual.
Safety Precautions
1) The Sanitron
2) Install the infrared wall spout and its' components only in a dry environment.
3) When performing any work on the
disconnect the power supply first, isolate the water supply and mask the sensor with a
solid black coloured PVC masking tape.
4) The transformer and the electrical components should be installed as far away from the
plumbing as the local safety regulations require.
5) Connect only the original supplied transformer to the IWS-0
6) For the installation and operation observe all relevant electrical, safety plumbing and building
standards.
7) All supplied components should only be used for the purpose they are designed for.
Installation
1)
Before installing the sensor plate make sure that the transformer which supplies the sensor
with power is disconnected from the mains supply. If the tap is powered by a battery
disconnect the battery.
2)
Adjust the installation flange so that it is flush with the finished wall surface (see fig.1).
3) Slowly o
pen the isolation valve inside the rough in box. Caution!! It is possible that water
will discharge briefly from the fitting where the spout will be connected later. The water
discharge will stop once the water pressure has built up behind the diaphragm of the
solenoid valve. Catch the spillage with a bucket.
4) Check that the black masking tape which is glued across the senor window is in-place (see
fig.2). The black masking tape will prevent the sensor from activating the solenoid. The tape
should only be removed once the compete installation is finished.
5) There are two low voltage cables attached to the sensor. One lead connects to the low voltage
output of the transformer (or battery depending on the model) and the other to the solenoid
valve. Plug them both into the corresponding plug or socket.
6) Screw the sensor plate with the supplied screws onto the fastening flange and the thread insert
of the installation box (see fig.2).
7) Install the spout. If the spout is installed at a later stage it is recommended that an end cap is
installed onto the spout connection fitting.
8) Test and adjust the sensor as required (see next page).
Wall lining
Installation flange
flush with wall lining
Note: FFL = Finished floor level; Technical details, layouts are schematic only; all details for construction by others; dimensions & technical information can change without further notice.
IWS-03F..
infrared wall spout and its components are for indoor use only.
IWS-03F..
4 Screws
fig.1
wall spout or its' connected components
3F...
.
SENSOR TAP
SWIPE HAND OVER SENSOR
FOR ON & OFF
fig.2
Black PVC masking tape
attached over this area.
Sensor
window
1 Screw

Advertisement

loading

Summary of Contents for Sanitron IWS-03F Series

  • Page 1 Before you start installing read the complete manual first ross reference this manual also with the IWS-03 manual. Safety Precautions 1) The Sanitron IWS-03F.. infrared wall spout and its components are for indoor use only. 2) Install the infrared wall spout and its’ components only in a dry environment.
  • Page 2 >> Extend or shorten the run time with the remote control Ph. 07 3875 2465, or via email: service@sanitron.com.au >> If above checks did not fix the problem please contact service. Note: FFL = Finished floor level; Technical details, layouts are schematic only; all details for construction by others; dimensions & technical information can change without further notice.