Download Print this page

PEI Enviro-Septic/SimpleSeptic Template 1A 2003 Instruction Manual

Advertisement

Quick Links

How To Use This Template,
Follow these steps to use the template to draw a
Procedure 2
sloping system end view.
end view
Step
Action
1
Use the % slope tool
13b
desired percentage of slope.
Example
:
2
Use the pipe end view cutouts
views of lines of pipe on the slope.
Example:
3
Use the % slope tool
13b
percentage of slope line as used in step 1 over the top of
the sloped pipes.
Example:
4
Add a slope ratio line
system.
Example:
The bend tools
3
Curved
maximum pipe bends in 1"-10' and 1"-20' curved
configuration
configurations.
Maximum bend at 1"-20'
®
Enviro-Septic
U.S. Patent Nos. 6,461,078; 5,954,451; 6,290,429 with other patents pending.
Canadian Patent Nos. 2185087; 2187126 with other patents pending. Simple-Septic
Patent No. 5,606,786. Presby Maze
®
®
Enviro-Septic
, Simple-Septic
, and Presby Maze
TM
Environmental Inc. Multi-Level
, is a trademark of Presby Environmental, Inc.
© 2003 Presby Environmental, Inc. All rights reserved. Publication date: July 2003
Continued
as a protractor to create a
Base Line
10
to draw end
Base Line
to add the same
Base Line
13a
to each side of the
Base Line
indicate the
12
®
U.S.
®
U.S. Patent No. 5,429,752.
®
are registered trademarks of Presby
Instruction Manual for use with
the Enviro-Septic
®
Septic
Template 1A 2003
20
40
1" = 20'
1.5'
1.75'
2'
2.25'
2.5'
2.75'
15
3.5'
10
2.75'
1.5'
3'
1.75'
4.5'
3.5'
2'
2.25'
5'
4'
2.5'
5
ENVIRO-SEPTIC
1.5'
1.75'
2'
2.25'
2.5'
2.75'
3.5'
10
20
1" = 10'
Template 1A 2003
®
This Enviro-Septic
Purpose
2003 is a drawing aid for our septic system designs.
This tool is used to accurately draw pipe and system
layouts in top and end views, and also to draw
sloping and curved configurations.
System length and pipe spacing are required to use
Prerequisite
this template. Use our "Enviro-Septic
®
Septic
Leaching Systems Design and Installation
Manual" and your State Attachment to calculate these
figures and other essential data.
PRESBY ENVIRONMENTAL, INC.
INNOVATIVE SEPTIC TECHNOLOGIES
Route 117 • PO Box 617 • Sugar Hill, NH 03585
Tel: 1-800-473-5298 • Fax: (603) 823-8114
www.PresbyEnvironmental.com
®
/Simple-
10'
80
60
MAX. BEND
1" = 20'
D-BOX SM
D-BOX LG
SM. TANK
LG. TANK
2:1
3:1
3' DIA.
4'DIA.
5' DIA.
4:1
5:1
PRESBY ENVIRONMENTAL, INC
BOX 617
SUGAR HILL, NH 03585
55
TEL: 1-800-473-5298
45
PRESBY ENVIRONMENTAL, INC. 2003
©
35
®
®
/SIMPLE-SEPTIC
25
TEMPLATE 1A 2003
15
5
MAX. BEND 1" = 10'
5'
30
40
5'
®
/Simple-Septic
Template 1A
®
& Simple-

Advertisement

loading

Summary of Contents for PEI Enviro-Septic/SimpleSeptic Template 1A 2003

  • Page 1 How To Use This Template, Instruction Manual for use with Continued Follow these steps to use the template to draw a ® Procedure 2 the Enviro-Septic /Simple- sloping system end view. end view ® Septic Template 1A 2003 Step Action Use the % slope tool as a protractor to create a desired percentage of slope.
  • Page 2 Template 1A 2003 Parts and Functions How To Use This Template Here are the template parts. Description Follow these steps to use the template to draw a Procedure 1 system top view. top view 1" = 20' Step Action MAX. BEND 1"...