Page 1
ETU01-Plus ETU01U-Plus Single V.35 Port G.703 E1 Access Unit...
Page 3
Far Eastern Vienna Technology Center 8F, No. 60 Zhouzi Street Neihu District, Taipei, 114 Taiwan ETU01-Plus (ETU01U-Plus) E1 Access Unit, Installation and Operation Manual Version 1.0 July 1, 2009 (Official Release) Version 1.1 August 21, 2009 Update Version 1.11 December 2, 2009 correction Version 1.2 March 25, 2010 Update...
Table of Contents CHAPTER 1 INTRODUCTION................7 1.0 W ......................7 ELCOME 1.1 P ..................7 RODUCT ESCRIPTION 1.2 T ................7 ECHNICAL PECIFICATIONS 1.3 E1 ..................10 SIGNAL STRUCTURE 1.4 ETU01-P ................11 APABILITIES 1.5 S ..............11 YSTEM IMING ONSIDERATIONS 1.6 F ................14 UNCTIONAL ESCRIPTION 1.7 L ..................15 OOPBACK...
Page 6
Table of Contents APPENDIX......................28 A.1 ETU01-P DIP S ............28 WITCH VERVIEW A.2 DIP SW1 T .............28 ETTING A.3 DIP SW2 T 15 S ............29 ETTING A.4 DIP SW3 T 16 T 23 S ............30 ETTING A.5 DIP SW4 T 24 T 31 S ............31 ETTING...
1.1 Product Description The ETU01-Plus is a single V.35 serial port access unit for E1 or Fractional E1 service. The ETU01U-Plus is a single V.35 serial port access unit for Unframed E1 only. The ETU01-Plus AC model has a universal, auto-switching power supply (90~250VAC) while the DC model's internal regulator module accepts DC voltages from 18 to 75 volts.
Page 8
Chapter 1. Introduction User Data Channel Fixed Interface -V.35 Interface Connectors V.35 Interface 34 pin, M-Block Female Line Code Data Rate N×56kbps or N×64kbps where N equal 1 to 31 in CCS and N equal 1 to 30 in CAS 2.048Mbps Unframed Clock Modes Clock Mode 0 (DCE1)
Page 9
Chapter 1. Introduction Diagnostics Test Switches/Diagnostics -Digital local loop back -Analog local loop back -Digital remote loop back -Test pattern / generator LED indicators Green Power Green Transmit data Green Receive data Green Request to sent Green Data carrier detect Tx CLK Loss Transmit clock loss Signal Loss...
Chapter 1. Introduction 1.3 E1 signal structure The E1 line operates at a nominal rate of 2.048Mbps. The data transferred over the E1 line is organized into frames, with each E1 frame containing 256 bits. The 256 bits consist of 32 time slots of eight bits each, which carry the data payload. E1 transmission utilizes two main types of framing: Frame Alignment Signal (FAS) and Multi-Frame Alignment Signal (MFAS).
External timing: The ETU01-Plus E1 link transmit clock is locked to the clock signal provided by the user DCE connected to the data channel. When the data channel is used as the clock source, the data channel must use clock timing mode 3 (DTE2) or 4 (DTE3).
Page 12
The ETU01-Plus can select from one of five clocking mode settings. Clock mode 0 (DCE 1): The ETU01-Plus data channel operates as a DCE and provides both transmit and receive clocks (recovered timing) to the data terminal equipment connected to the user channel.
Page 13
E1 transmit link. Clock mode 3 (DTE 2): The ETU01-Plus data channel is physically wired as DCE. However, the ETU01- Plus may operate as a DTE when connected to other DCE equipment by using a cross-over data cable and by setting the clock mode to the DTE2 setting. NOTE: The X.21 data channel cannot be operated in clock timing mode 3 (DTE2).
E1 transmit link. 1.6 Functional Description The ETU01-Plus is a single port access unit for E1 or Fractional E1 service. The ETU01U-Plus is a single port access unit for Unframed E1 only. The ETU01-Plus AC model has a universal, auto-switching power supply (90~250VAC) while the DC model's internal regulator module accepts DC voltages from 18 to 75 volts.
The operator at either end of the line may test both the ETU01-Plus and the line in the digital loop back mode. The loop back is controlled by either a manual switch or by the V.35 DTE interface.
Page 16
In the previous application, the ETU01-Plus is connected over hardwire point to point. The ETU01-Plus can also be connected to an E1 network or to E1's provided by SDH equipment. Within the SDH network, the E1 can be cross mapped at the VC12 level to provide point to point connections.
Install the ETU01-Plus within reach of an easily accessible grounded AC outlet. DC power capable units connect via terminal block connection. Allow at least 10 cm (4 inch) clearance at the rear of the ETU01-Plus for signal lines and interface cables. 2.3 Mechanical Assembly The ETU01-Plus is designed for tabletop or bench installation, and is delivered completely assembled.
RRING (Receive data in) Cable and Termination Use a shielded twisted pair cable between the ETU01-Plus and the DTE device. The receivers on the ETU01-Plus are 100 Ohm terminated. If problems are encountered with the connection to the V.35 DTE interface, make sure that the DTE interface is terminated correctly.
Page 20
Chapter 2. Installation Figure 2.4 ETU01U-Plus DIP Switches, Version 1.1G PCB Note: There are no timeslot setting switches (SW1-4) on the ETU01U-Plus model.
This chapter describes the ETU01-Plus controls and indicators, explains operating procedures, and supplies instructions for settings. Installation procedures (in Chapter 2) must be completed and checked before attempting to operate the ETU01-Plus. 3.2 Controls and Indicators All controls (push-button switches) and LED indicators are located on the ETU01- Plus front panel.
Page 22
Control Switch Function Loc dig loopbk The local digital loop back switch causes the local ETU01-Plus to loop E1 received data to its transmitter. Loc ana loopbk The local analog loop back switch causes the local ETU01-Plus to loop transmitter output back to its receiver.
2. Diagnostic loops are required. 3.3.1 Visual Indicators The ETU01-Plus is turned on when its AC power cord (or central office DC power) is connected to an AC power outlet (or the DC input connections) and the power switch is turned to the ON position. Initially, all LEDs will light, followed by all LEDs flashing rapidly 5 times.
Internal Oscillator timing Based on the above point to point application, use the following DIP switch graphic to visually set the ETU01-Plus units. This example will use CCS (PCM31) framing with CRC4 and provide 1024kbps (16 timeslots) throughput. ON=Enabled Pushbuttons...
The loop back test buttons (Loc dig loopbk, Loc ana loopbk and Rem loopbk) and the LED indicators built into the ETU01-Plus allow for rapid checking of the data terminal, ETU01-Plus and the E1 line. Before testing the operation of the data system equipment and their line circuits, ensure that all units are turned on and are configured correctly.
4.5 Local Digital Loop Back This test is activated by depressing the "Loc dig loopbk" button. The test consists of looping the received data back to the remote ETU01-Plus. This test checks the performance of the local ETU01-Plus, the remote ETU01-Plus and the connections between them (see Figure 4.3).
4.6 Remote Digital Loop Back This test is activated by depressing the "Rem loopbk" push button. The test determines the performance both of the local and the remote ETU01-Plus units, as well as their interconnecting lines. The remote digital loop back test consists of providing a loop back at the remote ETU01-Plus (see Figure 4.4).
Appendix A. DIP SW. Setting ETU01-Plus Appendix A.1 ETU01-Plus All DIP Switch Overview DIP SW FUNCTION COMMENT GROUP Time slot 0 to 7 setting See Table A.2 Time slot 8 to 15 setting See Table A.3 Time slot 16 to 23 setting See Table A.4...
Appendix A. DIP SW. Setting ETU01-Plus A.3 DIP SW2 Time Slot 8 To 15 Setting DIP SW2 STATE FUNCTION COMMENT Time slot 8 disable Time slot 8 enable Time slot 9 disable Time slot 9 enable Time slot 10 disable...
Appendix A. DIP SW. Setting ETU01-Plus A.4 DIP SW3 Time Slot 16 To 23 Setting DIP SW3 STATE FUNCTION COMMENT Time slot 16 disable Time slot 16 enable Note 1 Time slot 17 disable Time slot 17 enable Time slot 18 disable...
Appendix A. DIP SW. Setting ETU01-Plus A.5 DIP SW4 Time Slot 24 To 31 Setting DIP SW4 STATE FUNCTION COMMENT Time slot 24 disable Time slot 24 enable Time slot 25 disable Time slot 25 enable Time slot 26 disable...
Appendix A. DIP SW. Setting ETU01-Plus A.6 DIP SW5 Parameter Group 1 Setting DIP SW5 STATE FUNCTION COMMENT STATE OFF OFF OFF Clock mode 0 (DCE1) ON OFF OFF Clock mode 1 (DCE1) OFF ON OFF Clock mode 2 (DTE1)
Appendix A. DIP SW. Setting ETU01-Plus A.7 DIP SW6 Parameter Group 2 Setting DIP SW6 STATE FUNCTION COMMENT STATE Line Impedance: 120 Ohm TP (RJ-45) Line Impedance: 75 Ohm Coaxial (BNC) RC Phase: Normal RC Phase: Inverted TC Phase: Normal TC Phase: Inverted DCD always ON, except E1 Sig.Loss...
Appendix A. DIP SW. Setting ETU01-Plus A.8 Clock Mode Details CLOCK DIPSW 5 E1 LINE USER DATA PORT MODE STATE TRANSMIT RECEIVE TRANSMIT CLOCK CLOCK CLOCK RECOVERY RECOVERY OFF OFF OFF RECOVERY (DCE1) Output to RC Output to TC INTERNAL...
Appendix A. DIP SW. Setting ETU01U-Plus B.1 ETU01U-Plus All DIP Switch Overview DIP SW FUNCTION COMMENT GROUP Parameter group 1 setting See Table B.2 Parameter group 2 setting See Table B.3 Table B.1 All DIP Switch Overview Note: The ETU01U-Plus operates in unframed mode ONLY. The user data rate is fixed at 2048K.
Appendix A. DIP SW. Setting ETU01U-Plus B.5 Clock Mode Details CLOCK DIPSW 5 E1 LINE USER DATA PORT MODE STATE TRANSMIT RECEIVE TRANSMIT CLOCK CLOCK CLOCK RECOVERY RECOVERY OFF OFF OFF RECOVERY (DCE1) Output to RC Output to TC INTERNAL INTERNAL INTERNAL ON OFF OFF...
Appendix C. Interface Connections C.1 E1 Line Connectors C.1.1 BNC Connectors Conn. Designation Direction Function Center TTIP From ETU01-Plus Transmit data ↔ Sleeve TRING Signal return Center RTIP To ETU01-Plus Receive data ↔ Sleeve RRING Signal return Table C.1a E1 BNC connector pin allocation C.1.2 RJ-45 Connector...
Appendix C. Interface Connections C.2 V.35 Data Connector The ETU01-Plus comes with a fixed V.35 interface. This interface behaves as DCE for direct connection to DTE devices such as routers. The physical interface is a 34- pin female M-type (Winchester) connector wired in accordance with Table C.2.
Page 40
Appendix C. Interface Connections This page left blank intentionally.
Page 41
CTC Union Technologies Inc Fax:(886)2 27991355 Tel:(886)2 26591021 Attn : Technical Support Division E-mail:info@ctcu.com From Company: Taipei Taiwan Name: Tel: ( Fax:( MODEL: ETU01-Plus ETU01U-Plus ACTIVITY: As attached in DIP switch setting table SYS CONFIGURATION: Question:...
Page 42
Technical Inquiry Form MODEL No.: ETU01-Plus ETU01U-Plus Please fill in the DIP switches configuration with ' ' marks into the following table. Send it to us by fax, and we will reply to you immediately. Your Setting CTC Suggestion SW NO.
Need help?
Do you have a question about the ETU01-Plus and is the answer not in the manual?
Questions and answers