Download Print this page

Sirius Satellite Radio SLTC61 Instructions For Use Manual page 12

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 12
WARNINGS
* The appliance is not intended for use by
young children or infirm persons without
supervision. Young children should be su-
pervised to ensure they do not play with
the appliance.
The minimum distance between the cook
top surface and the lower side of the
cooker hood must be 40 cm for models
SLTC61, SLTC65, SLT66 and SLTC68, while
for model SLTC62, the minimum distan-
ce between the cook top and the bottom
of the appliance must not be lower than
65Cm.
* The air sucked can't be conveyed throu-
gh or into a duct used to let out fumes
from appliances fed by energy other than
electric power (eg. centralized heating, ra-
diators, water-heaters, etc.).
* To evacuate the air outlet, please comply
with the pertaining rules given by compe-
tent authorities.
* Provide the room with an adequate aeration
when a cooker hood and appliances fed by
energy other than electric power (gas-, oil-,
or coal- stoves, etc.) are used simultaneously.
The cooker hood, when evacuating the sucked
air, could generate a negative pressure in the
room- which can't exceed the limit of 0.04
mbar, in order to avoid the suck of exhausts
deriving from the heat-source. Therefore the
room should be provided with air-intakes to
allow a costant flow of fresh air.
If the rating lable in the cooker-hood
shows the symbol
built in class II° and it does not need any
earth connection.
If the rating lable in the cooker-hood does
not show the symbol
built in class I° and it needs the earth con-
nection.
* When performing the electrical connections on
the appliance, please make sure that the current-
tap is provided with earth connection and that
voltage values correspond to those indicated on
the label placed inside the appliance itself.
, the appliance is
, the appliance is
* Before carrying out any cleaning or main-
taining operations, the appliance needs to
be removed from the electric grid. If the ap-
pliance is not provided with a non-separable
flexible cable and plug, or with another de-
vice ensuring omnipolar disconnections from
the grid, with an opening distance between
the contacts of at least 3 mm, then such di-
sconnecting devices must be supplied within
the fixed installation.
If the fixed appliance is endowed with a sup-
ply cord and a plug, the appliance has to be
put in a place where the plug can be reached
easily.
* The use of materials which can burst into
flames should be avoided in close proxi-
mity of the appliance. When frying, please
pay particular attention to fire risk due to
oil grease. Being highly inflammable, fried
oil is especially dangerous. Do not use un-
covered electric grills.
In order to avoid possible fire risk, all in-
structions for grase-filter cleaning and for
removing eventual grease deposits should
be strictly followed.
The appliance is already arranged both for
filtering and for suction performances.
* In its filtering version (Fig.1), the air and
fumes conveyed by the appliance are depured
both by a grease filter and by an active coal
filter, and put again into circulation through
the side-grids of the chimney. For this ver-
sion an air deflector placed on the superior
part of the pipe and allowing air-recycling is
necessary (Fig.1A).
* In its sucking version (Fig.2), fumes are di-
rectly conveyed outside, through an evacua-
tion duct connected with the superior part of
the wall or the ceiling. Both coal filter and air
deflector are not necessary in this case.
12
USES

Advertisement

loading

This manual is also suitable for:

Sltc62Sltc65Slt66Sltc68Fsla