TouchWand InWand TW303100 Series Manual

Double micro module switch

Advertisement

Quick Links

InWand™
TouchWand™
TW303100 (AC) /
TW303200 (24VDC)
DOUBLE MICRO
MODULE SWITCH
Page 1 of 15

Advertisement

Table of Contents
loading

Summary of Contents for TouchWand InWand TW303100 Series

  • Page 1 InWand™ TouchWand™ TW303100 (AC) / TW303200 (24VDC) DOUBLE MICRO MODULE SWITCH Page 1 of 15...
  • Page 2: Table Of Contents

    Contents Contents ............................2 General ............................3 Safety Precautions ........................4 Installation Procedure ....................... 5 Wiring Diagrams ......................... 5 Legend ............................6 Adding to Z-Wave Network ...................... 7 Terminology ..........................7 Manual Inclusion and Exclusion .................... 8 Z-Wave multichannel endpoints ..................... 8 Basic command ..........................
  • Page 3: General

    General This device is a Z-Wave Plus™ enabled transceiver fully compatible with any Z-Wave™ enabled network. Its miniature size allows the module to be easily hidden in a wall box, making home design easier and slicker than ever. The module has many applications switching AC/DC power on and off, e.g., controlling lights, window shutters and much more.
  • Page 4: Safety Precautions

    Safety Precautions • Verify part number before installation to avoid miss-match of operating voltage • Choosing a Suitable Location • Do not locate the device facing direct sunlight, or in a humid or dusty place. • Suitable ambient temperature for the device is 0°C-40°C. •...
  • Page 5: Installation Procedure

    Installation Procedure • Connect the device according to one of the wiring diagrams shown below, as appropriate for your application. • Make sure the controller is NOT in inclusion mode and turn on the power for the device. • Configure the device as desired (lights / shutter mode), as described below and turn the device power off when finished.
  • Page 6: Legend

    Legend • SW1 - Switch terminal 1 • SW2 - Switch terminal 2 • NO1 - Normally Open terminal 1 • NO2 - Normally Open terminal 2 • N - Neutral lead • L - Live lead One Light circuit Two Light circuits Shutter Scenario / Repeater...
  • Page 7: Adding To Z-Wave Network

    Adding to Z-Wave Network To work with other Z-Wave enabled devices, the device needs to be assigned a node ID by the network controller. When power is applied, and the device does not have a node ID (such as when it is activated for the first time or after it has been reset to factory default settings), its LED starts to blink at half-second intervals according to the following: •...
  • Page 8: Manual Inclusion And Exclusion

    Manual Inclusion and Exclusion The device can also be manually added to or excluded from the network. See the instructions for your Z-Wave Controller how to access the setup function to include and exclude devices. Green LED will blink Inclusion alternatively for 2 minutes 1.
  • Page 9: Normal State Led Indications

    Normal State LED Indications In the Normal state, the LED indicates which relays are active as follows: • If Relay 1 is on, the LED is Red. • If Relay 2 is on, the LED is Green. • If both Relay 1 and Relay 2 are on, the LED is Orange. This state can occur only in Lights mode, not in Shutter mode.
  • Page 10 Action Configuration Button LED Activity and Results Send Meter Report Press 1 time within 1 second Sends Meter Report. Enter/Exit Sends Node ID. inclusion/ exclusion Press 3 times within 1 second LED blinks green - unpaired mode LED blinks red - paired LED flashes orange 3 times.
  • Page 11: Security

    Security This device is a security enabled Z-Wave Plus product (S2), which is able to use encrypted Z- Wave Plus messages to communicate to other security enabled Z-Wave Plus products. This device must be used in conjunction with a Security Enabled Z-Wave Controller to fully utilize all implemented functions.
  • Page 12: Configuration Parameters (Decimal Values)

    Configuration Parameters (Decimal Values) Function Size Value Default Description Toggle/ Momentary 1 Byte for Switch #1 Send 1 for Toggle mode Send 2 for Momentary mode Toggle/ Momentary 1 Byte for Switch #2 Measure the time (sec.) it takes the shutter to go up from the moment Shutter up time* 1 Byte...
  • Page 13: Association Groups

    Association groups • Double Switch Maximum Description number of nodes Sends binary switch report when switch state is Group 1 changed, Meter reports every 2 hours Group 2 Sends Basic Set when switch state is changed • Shutter Maximum Description number of nodes Sends Multilevel switch reports when window cover Group 1...
  • Page 14: Troubleshooting

    Part number model: TW303100 (Vac) / TW303200 (24Vdc) Trade/Brand name: InWand™ Changes or modifications not expressly approved by TouchWand Ltd. for compliance could void the user's warranty of the equipment. This equipment radiates radio frequency energy. If not installed and used in accordance with the instructions, may cause interference to radio communications.
  • Page 15 Trademarks TouchWand and the TouchWand logo are registered trademarks. All other product names mentioned may be trademarks or registered trademarks of their respective companies. Page 15 of 15...

Table of Contents