Page 2
By analyzing various indicators of signal quality to determine the strength and stability of the signal, NB007 guides users to quickly select the best installation location and the best network operator for installation of terminals. It can be widely used in multiple industries like power supply, water supply, gas supply, environmental protection monitoring, water conservancy, meteorology, heat pipe network, coal mine, oil field, etc.
Page 3
User Manual of NB007 Analyzer Foreword Convention Symbolic convention Connotations of the following symbols in the document are as follows. Symbol Description Texts starting by this symbol means there are potential risks, and if the texts are ignored, it may result in device damages, data loss, device performance degradation or unpredictable results.
Main page ............................10 Network ..............................12 Map ..............................14 3.4 Automatic power off /sleep mode ......................15 4 FAQ/Troubleshooting ..........................16 5.1 Overview ............................16 5.2 NB007 PING test result is error or timeout ..................16 5.3 Device is unable to power on ......................16 Doc V1.0...
1.2 Product positioning NB007 NB-IoT analyzer is a portable testing product specialized in providing analysis on signal network quality. Signal strength and stability are specified through testing and analyzing indicators of signal quality, and network communication quality is determined by using network testing tool. Users are instructed to swiftly choose the best internet service provider with optimized network coverage and the position suitable for mounting wireless device antenna.
NB007 Analyzer User Manual Installation Installation 2.1 Overview This chapter introduces NB007’s basic usage and mounting method. 2.2 Packaging list NB007 includes the accessories shown in table 2-1. Table 2-1 NB007 Analyzer packaging list Accessory name Quantity Remark Standard configuration Packed as per client’s state of order...
NB007 Analyzer User Manual Installation Graph 2-1 Mounting SIM card 2.4 Battery mounting and charging Step 1: remove the battery cover from the back panel Step 2: mount battery as per the direction indicated on battery cover of the device Step 3: mount battery cover to the device.
Device restores default configuration and restarts ○ more than 3s 2.6 LED indicator There are totally 4 LED indicators at the front panel of NB007, indicating the operating status of the device, as is shown in graph 2-3. Doc V1.0 2 -6...
Page 11
NB007 Analyzer User Manual Installation Graph 2-3 Graphic representation of LED indicator Table 2-2 LED status description LED indicator Indication Description Always on Working normally POWER Blinking Powering off Power off/sleep mode Green CSQ:15-31 Yellow CSQ:10-14 SIGNAL CSQ:1-9 No signal/power off...
Bluetooth name is: “default name_the last four digits of Bluetooth mac”. For example, if Bluetooth mac address is e8:0f:d2:8a:c9:eb, the effected Bluetooth name during default configuration is: NB007_C9EB. 2. If revised Bluetooth name is not NB007, actual effected name is consistent with configured Bluetooth name, and last four d igits of mac address will not be added.
Page 13
Step 3: Configure Bluetooth connection parameters, and the description is as shown in table 3-2. Table 3-2 Bluetooth name configuration parameter description Parameter name Parameter description Bluetooth name It’s used for reviewing Bluetooth name that changes currently connected devices, and default configuration is NB007. Doc V1.0 3 -9...
NB007 Analyzer User Manual Initial Configuration 3.3 APP APP is mainly responsible for completing dial parameter configuration of the device, signal quality detection, ping test, delay test, export and share as reports, which contain location information. Main page Main page is mainly for displaying signal parameters, creating signal statistic graph, and performing PING test, delay test and export report function.
Page 15
NB007 Analyzer User Manual Initial Configuration Graph 3-4 Adding ping setting IP tag 2. Return to MAIN page, click “PING” button to conduct PING test D-TEST 1. Click “ ” to enter into Setting tag; revise Delay Test time; default is 10s, which means the testing will be lauched after 10s, as is shown in graph 3-5.
NETWORK page provides device dialing parameter configuration. It is the core function of NB007, and provides security for user’s signal quality test. NB007 supports 3 SIM cards and 1 ESIM card inserted and only 1 SIM/ESIM can be dial up at the same time. NB007 supports CAT NB, CAT M, and GSM network.
Page 17
NB007 Analyzer User Manual Initial Configuration Step 3: configure NETWORK parameters, as is shown in graph 3-6, and NETWORK parameters description is as is shown in table 3-3. Graph 3-7 NETWORK tag Table 3-3 NETWORK tag parameters description Parameter name...
Reboot Click “Reboot” button; reboots the NB007 device currently connected. Restore Click “Restore” button, conduct factory reset operation for NB007 device currently connected. After parameters are modified, only by clicking “Save” button to save can parameters be effective. --- End MAP page is for showing the position of current test.
NB007 Analyzer User Manual Initial Configuration 3.4 Automatic power off /sleep mode Step 1 Enable the Auto power off function, choose how long you want it to automatically power off. Graph 3-1 Automatic power off parameter configuration tag Without extended power supply: if there is no data transmitting via Bluetooth or serial interface during Auto Power off period, the device will be powered off automatically.
FAQ/Troubleshooting FAQ/Troubleshooting 5.1 Overview This chapter mainly introduces causes to common failure and treatment methods in the process of using NB007. 5.2 NB007 PING test result is error or timeout Failure phenomenon NB007 PING test result is error or timeout.
Page 21
Shenzhen Hongdian Technologies Corporation. Trade mark statement , DTU, NB007 is the trademark owned by Shenzhen Hongdian Technologies Corporation. Other trademark mentioned in the manual is owned by the institute that has the proprietary over the trademark, and Hongdian Corporation has no ownership right in other trademark.
Need help?
Do you have a question about the NB007 and is the answer not in the manual?