Certification Test Report
Models: GWS-2200, GWS-2200-B, WSL-2200, WSL-2200-B,
LWS-2200, WS-2200, WS-2200-B, PH2200WS, PH2200WS-B,
SWS-2200, SWS-2200-B, HWS-2200, HWS-2200-B, PWS-2200-B
Prepared for:
Prepared by:
Test Period:
Report Issued:
Report Number:
All data and information contained in this report are confidential and proprietary to GHP
Group, Inc. Its significance is subject to the adequacy and representative character of the
samples and to the comprehensiveness of the tests, examinations, or surveys made. The
contents of this report cannot be copied or quoted, except in full, without specific, written
authorization from GHP Group, Inc. and OMNI-Test Laboratories, Inc. No use of the
OMNI-Test Laboratories, Inc. name, logo, or registered mark (O-TL) is permitted, except as
expressly authorized by OMNI-Test Laboratories, Inc. in writing.
(Non-CBI)
GHP Group, Inc.
Model Name: Large Wood Stove, Legs
Large Wood Stove, Pedestal
Wood-Fired Freestanding Room Heater
GHP Group, Inc.
6440 W Howard St
Niles, IL 60714
USA
OMNI-Test Laboratories, Inc.
13327 NE Airport Way
Portland, OR 97230
(503) 643-3788
May 5, 2020 – May 6, 2020
June 22, 2020
0418WS018E
-Document Edition # 000 (06/22/20)-

Advertisement

Table of Contents
loading

Summary of Contents for GHP Group GWS-2200

  • Page 1 GHP Group, Inc. and OMNI-Test Laboratories, Inc. No use of the OMNI-Test Laboratories, Inc. name, logo, or registered mark (O-TL) is permitted, except as expressly authorized by OMNI-Test Laboratories, Inc.
  • Page 2 GHP Group, Inc. Model: Large Wood Stove Report Number:0418WS018E AUTHORIZED SIGNATORIES This report has been reviewed and approved by the following authorized signatories: Evaluator: __________________________ ____ ____ ____ ____ ____ Bruce Davis Testing Manager Reviewer: ___________________________ Alex Tiegs President...
  • Page 3: Table Of Contents

    GHP Group, Inc. Model: Large Wood Stove Report Number:0418WS018E TABLE OF CONTENTS PREFACE ....................... (3 pages) SAMPLING PROCEDURES AND TEST RESULTS............4 Introduction ..........................5 Individual Run summaries ....................6 Summary Tables Table 1 - Particulate Emissions Results ................7 Table 2 - Particulate Emissions Results (First Hour)............7 Table 3 –...
  • Page 4: Sampling Procedures And Test Results

    GHP Group, Inc. Model: Large Wood Stove Report Number:0418WS018E Section 1 Sampling Procedures and Test Results 4 of 142...
  • Page 5: Introduction

    Report Number:0418WS018E INTRODUCTION GHP Group, Inc. retained OMNI to perform U.S. Environmental Protection Agency (EPA) certification testing on the Large Wood Stove Freestanding woodstove. The Large Wood Stove Freestanding wood stove is a Non-Catalytic-type room heater. The firebox is constructed of mild steel.
  • Page 6: Individual Run Summaries

    GHP Group, Inc. Model: Large Wood Stove Report Number:0418WS018E INDIVIDUAL RUN SUMMARIES Run 1 - Test procedures followed to produce a high burn rate with a primary air setting of fully open. Observed burn rate was calculated at 5.18 kg/hr. Emissions results were calculated using particulate sampling from kindling, start-up fuel, and test fuel load combined (cold to hot).
  • Page 7 GHP Group, Inc. Model: Large Wood Stove Report Number:0418WS018E Table 1 – Particulate Emissions Burn Rate ASTM E3053 ASTM E3053 Weighted Calculated from a Weighting Factor Emissions Hot to Hot burn ASTM E2515 (g/h) cycle Emissions (kg/h dry) (g/h) 5.18 4.65...
  • Page 8 GHP Group, Inc. Model: Large Wood Stove Report Number:0418WS018E Table 4 – Test Facility Conditions Room Temperature Barometric Pressure Air Velocity (°F) (Hg) (ft/min) Before After Before After Before After 29.43 29.41 <50 <50 29.35 29.45 <50 <50 29.74 29.74 <50...
  • Page 9 GHP Group, Inc. Model: Large Wood Stove Report Number:0418WS018E Table 6 – Fuel Measurement and Cordwood Description Summary – TEST Cherry Cordwood Test Fuel Firebox Consumed Volume Fuel Loading Test Fuel During Test Test Fuel Density Wet Dry Basis Dry Basis...
  • Page 10 GHP Group, Inc. Model: Large Wood Stove Report Number:0418WS018E Table 10 – Test Configurations Startup Procedures Combustion Air Fuel Loading: Kindling and start-up fuel loaded together; a torch was used for 20 seconds to establish a fire. At 45 minutes placed fuel load into the firebox and closed the loading door.
  • Page 11: Photographs/Appliance Description/Drawings

    GHP Group, Inc. Model: Large Wood Stove Report Number:0418WS018E Section 2 Photographs/Appliance Description/Drawings OMNI-Test Laboratories, Inc. 11 of 142...
  • Page 12 GHP Group, Inc. Model: Large Wood Stove Report Number:0418WS018E GHP Group, Inc. Model Large Wood Stove Test Dates: May 5, 2020 – May 6, 2020 Front Left View Rear View Front Right View OMNI-Test Laboratories, Inc. 12 of 142...
  • Page 13 GHP Group, Inc. Model: Large Wood Stove Report Number:0418WS018E GHP Group, Inc. Model Large Wood Stove Run 1 – Kindling and start-up fuel Run 1 Kindling and start-up fuel Run 1 – Ignition of kindling Run 1 Fuel load OMNI-Test Laboratories, Inc.
  • Page 14 GHP Group, Inc. Model: Large Wood Stove Report Number:0418WS018E GHP Group, Inc. Model Large Wood Stove Run 1 – Test Fuel Load In Stove Run 1 Remaining Coal After Test Run 2 – Test Fuel Load Run 2 Test Fuel Loaded into Stove Note: Photo not available for report OMNI-Test Laboratories, Inc.
  • Page 15 GHP Group, Inc. Model: Large Wood Stove Report Number:0418WS018E Run 2 – Remaining Coal After Test Run 3 – Kindling and start-up fuel Run 3 – Test Fuel Load Run 3 – Test Fuel Loaded into Stove OMNI-Test Laboratories, Inc.
  • Page 16 GHP Group, Inc. Model: Large Wood Stove Report Number:0418WS018E Run 3 - Remaining Coal After Test Run 4 – Test Fuel Load Run 4 – Test Fuel Loaded into Stove Run 4 Remaining Coal After Test OMNI-Test Laboratories, Inc. 16 of 142...
  • Page 17 GHP Group, Inc. Model: Large Wood Stove Report Number:0418WS018E WOOD HEATER DESCRIPTION Appliance Manufacturer: GHP Group, Inc. Wood Stove Model: Large Wood Stove Type: Freestanding Wood Fired Room Heater WOOD HEATER INFORMATION Materials of Construction: The unit is constructed primarily of mild steel. The firebox is lined with 1.25”...
  • Page 18: Model Similarities

    GHP Group, Inc. Model: Large Wood Stove Report Number:0418WS018E MODEL SIMILARITIES Large Wood Stove, Legs; Large Wood Stove, Pedestal; GWS-2200 PH2200WS GWS-2200-B PH2200WS-B WSL-2200 SWS-2200 WSL-2200-B SWS-2200-B LWS-2200 HWS-2200 WS-2200 HWS-2200-B WS-2200-B PWS-2200-B Besides "Leg" vs. "Pedestal" parts for the base, all models have exactly the same firebox design and overall dimensions.
  • Page 19: Test Data By Run

    GHP Group, Inc. Model: Large Wood Stove Report Number:0418WS018E Section 3 Test Data by Run OMNI-Test Laboratories, Inc. 19 of 142...
  • Page 20 Fueling instructions for use with ASTM E3053-17 GHP Large with By-Pass High Burn Proced Kindling: Kindling weight in total should be 3.5lbs (±0.5bs) ten pieces in total of equal size, 15-17’’ in length. Making sure the weight doesn’t exceed what’s allowed per the standard.
  • Page 21 Fueling instructions for use with ASTM E3053-17 to be scattered on each layer. This comes from the 0.9-1.0lbs of the total kindling weight. Bottom: Two kindling and two start-up pieces East/West : Two kindling and two start-up pieces North/South : Two kindling and two start-up pieces East/West : Two kindling and two start-up pieces North/South : Two kindling and two start-up pieces East/West Top: A pile of small kindling pieces in the middle as shown in the picture below,...
  • Page 22 Fueling instructions for use with ASTM E3053-17 start-up phase you may need to reposition the fuel for maximum combustion. This usually will happen around 30-35 minutes. If the flames on top start to go out, open the door and grab the raw fuel on the bottom and move it on top in a pile to get any raw fuel burnt up.
  • Page 23 Fueling instructions for use with ASTM E3053-17 GHP Large with By-Pass Medium and Low Procedure Test Fuel: Follow the guidelines of the cordwood standard (E3053-17) for correct moisture and weight ratios for the core and sub loads. There are six pieces in total. The nominal length is 16’’.
  • Page 24 Fueling instructions for use with ASTM E3053-17 four minutes. Use the by-pass at the start of the test if needed. There should be minimal gaps between all fuel pieces. Three smaller pieces in a North/South direction and the remaining three pieces on top in an East/West direction (see test fuel picture above).
  • Page 25 OMNI-Test Laboratories, Inc. Conditioning Data - ASTM E2780/ ASTM E2515 Manufacturer: GHP Group Model: GHP Large Tracking No.: 2409 Project No.: 0418WS018E Test Date: Febuary 2020 Technician: Nelke Consulting Operation Category: Flue Gas Flue Gas Elapsed Time Elapsed Time Temp...
  • Page 26 26 of 142...
  • Page 27: Run 1

    GHP Group, Inc. Model: Large Wood Stove Report Number:0418WS018E Run 1 High Burn 1-minute data Emissions Results (Cold to Hot Cycle) OMNI-Test Laboratories, Inc. 27 of 142...
  • Page 28 OMNI-Test Laboratories, Inc. Wood Heater Test Data - ASTM E3053 / ASTM E2515 Run: Manufacturer: GHP Group PM Control Modules: 371, 372 Model: Large Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 20.14 ft/sec. Tracking No.: 2409 Total Sampling Time: Dilution Tunnel MW(wet): 28.78 lb/lb-mole...
  • Page 29 OMNI-Test Laboratories, Inc. Wood Heater Test Data - ASTM E3053 / ASTM E2515 Run: Manufacturer: GHP Group PM Control Modules: 371, 372 Model: Large Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 20.14 ft/sec. Tracking No.: 2409 Total Sampling Time: Dilution Tunnel MW(wet): 28.78 lb/lb-mole...
  • Page 30 OMNI-Test Laboratories, Inc. Wood Heater Test Data - ASTM E3053 / ASTM E2515 Run: Manufacturer: GHP Group PM Control Modules: 371, 372 Model: Large Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 20.14 ft/sec. Tracking No.: 2409 Total Sampling Time: Dilution Tunnel MW(wet): 28.78 lb/lb-mole...
  • Page 31 OMNI-Test Laboratories, Inc. Wood Heater Test Data - ASTM E3053 / ASTM E2515 Run: Manufacturer: GHP Group PM Control Modules: 371, 372 Model: Large Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 20.14 ft/sec. Tracking No.: 2409 Total Sampling Time: Dilution Tunnel MW(wet): 28.78 lb/lb-mole...
  • Page 32 OMNI-Test Laboratories, Inc. Wood Heater Lab Data - ASTM E3053 / ASTM E2515 Manufacturer: GHP Group Equipment Numbers: Model: Large Tracking No.: 2409 Project No.: 0418WS018E Run #: 1 Date: 5/5/20 TRAIN 1 (First Hour emissions) Sample Component Reagent Filter, Probe...
  • Page 33 OMNI-Test Laboratories, Inc. Wood Heater Test Results - ASTM E3053 / ASTM E2515 Manufacturer: GHP Group Model: Large Project No.: 0418WS018E Tracking No.: 2409 Run: 1 Test Date: 05/05/20 Burn Rate 4.69 kg/hr dry Average Tunnel Temperature 143 degrees Fahrenheit Average Gas Velocity in Dilution Tunnel - vs 20.14 feet/second...
  • Page 34 Adjunct to ASTM E XXXX Wood Heater Cordwood Test Method May 10, 2017 Version THIS DOCUMENT IS NOT AN ASTM STANDARD; IT IS UNDER CONSIDERATION WITHIN AN ASTM TECHNICAL COMMITTEE BUT HAS NOT RECEIVED ALL APPROVALS REQUIRED TO BECOME AN ASTM STANDARD. Cordwood Fuel Load Calculators 10 lb/ft Nominal Load Density IT SHALL NOT BE REPRODUCED OR CIRCULATED OR QUOTED, IN WHOLE OR IN PART, OUTSIDE OF ASTM...
  • Page 35 35 of 142...
  • Page 36 36 of 142...
  • Page 37: Run 2

    GHP Group, Inc. Model: Large Wood Stove Report Number:0418WS018E Run 1 High Burn 1-minute data Efficiency and Heat Output Results Kindling and start-up fuel removed from calculations OMNI-Test Laboratories, Inc. 37 of 142...
  • Page 38 OMNI-Test Laboratories, Inc. Wood Heater Test Data - ASTM E3053 / ASTM E2515 Run: Manufacturer: GHP Group PM Control Modules: 371, 372 Model: Large Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: #DIV/0! ft/sec. Tracking No.: 2409 Total Sampling Time: Dilution Tunnel MW(wet): 28.78 lb/lb-mole...
  • Page 39 OMNI-Test Laboratories, Inc. Wood Heater Test Data - ASTM E3053 / ASTM E2515 Run: Manufacturer: GHP Group PM Control Modules: 371, 372 Model: Large Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: #DIV/0! ft/sec. Tracking No.: 2409 Total Sampling Time: Dilution Tunnel MW(wet): 28.78 lb/lb-mole...
  • Page 40 OMNI-Test Laboratories, Inc. Wood Heater Test Data - ASTM E3053 / ASTM E2515 Run: Manufacturer: GHP Group PM Control Modules: 371, 372 Model: Large Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: #DIV/0! ft/sec. Tracking No.: 2409 Total Sampling Time: Dilution Tunnel MW(wet): 28.78 lb/lb-mole...
  • Page 41 OMNI-Test Laboratories, Inc. Wood Heater Test Results - ASTM E3053 / ASTM E2515 Manufacturer: GHP Group Model: Large Project No.: 0418WS018E Tracking No.: 2409 Run: 1 Test Date: 05/05/20 Burn Rate 5.18 kg/hr dry Average Tunnel Temperature #DIV/0! degrees Fahrenheit...
  • Page 42 Wood Heater Efficiency Results - CSA B415.1 B415.1 GHP Group Manufacturer: Technician Signature: Large Model: 05/05/20 Date: Run: Control #: 0418WS018E Test Duration: Output Category: Test Results in Accordance with CSA B415.1-09 HHV Basis LHV Basis 71.8% 77.0% Overall Efficiency 97.4%...
  • Page 43 Adjunct to ASTM E XXXX Wood Heater Cordwood Test Method May 10, 2017 Version THIS DOCUMENT IS NOT AN ASTM STANDARD; IT IS UNDER CONSIDERATION WITHIN AN ASTM TECHNICAL COMMITTEE BUT HAS NOT RECEIVED ALL APPROVALS REQUIRED TO BECOME AN ASTM STANDARD. Cordwood Fuel Load Calculators 10 lb/ft Nominal Load Density IT SHALL NOT BE REPRODUCED OR CIRCULATED OR QUOTED, IN WHOLE OR IN PART, OUTSIDE OF ASTM...
  • Page 44: Run 3

    GHP Group, Inc. Model: Large Wood Stove Report Number:0418WS018E Run 1 High Burn 10-minute data Proportional Rate Verification This data set is presented to verify that when proportional rates are calculated at the required 10- minute interval, required specification that only one reading can be outside of the 90% to 110% are maintained.
  • Page 45 OMNI-Test Laboratories, Inc. Wood Heater Test Data - ASTM E3053 / ASTM E2515 Run: Manufacturer: GHP Group PM Control Modules: 371, 372 Model: Large Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 20.14 ft/sec. Tracking No.: 2409 Total Sampling Time: Dilution Tunnel MW(wet): 28.78 lb/lb-mole...
  • Page 46 OMNI-Test Laboratories, Inc. Wood Heater Test Results - ASTM E3053 / ASTM E2515 Manufacturer: GHP Group Model: Large Project No.: 0418WS018E Tracking No.: 2409 Run: 1 Test Date: 05/05/20 Burn Rate 4.69 kg/hr dry Average Tunnel Temperature 139 degrees Fahrenheit Average Gas Velocity in Dilution Tunnel - vs 20.14 feet/second...
  • Page 47: Run 4

    GHP Group, Inc. Model: Large Wood Stove Report Number:0418WS018E Run 2 Medium Burn OMNI-Test Laboratories, Inc. 47 of 142...
  • Page 48 OMNI-Test Laboratories, Inc. Wood Heater Test Data - ASTM E3053 / ASTM E2515 Run: Manufacturer: GHP Group PM Control Modules: 371, 372 Model: GHP Large Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 20.62 ft/sec. Tracking No.: 2409 Total Sampling Time: Dilution Tunnel MW(wet): 28.78 lb/lb-mole...
  • Page 49 OMNI-Test Laboratories, Inc. Wood Heater Test Data - ASTM E3053 / ASTM E2515 Run: Manufacturer: GHP Group PM Control Modules: 371, 372 Model: GHP Large Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 20.62 ft/sec. Tracking No.: 2409 Total Sampling Time: Dilution Tunnel MW(wet): 28.78 lb/lb-mole...
  • Page 50 OMNI-Test Laboratories, Inc. Wood Heater Test Data - ASTM E3053 / ASTM E2515 Run: Manufacturer: GHP Group PM Control Modules: 371, 372 Model: GHP Large Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 20.62 ft/sec. Tracking No.: 2409 Total Sampling Time: Dilution Tunnel MW(wet): 28.78 lb/lb-mole...
  • Page 51 OMNI-Test Laboratories, Inc. Wood Heater Lab Data - ASTM E3053 / ASTM E2515 Manufacturer: GHP Equipment Numbers: Model: Large Tracking No.: 2409 Project No.: 0418WS018E Run #: 2 Date: 5/5/20 TRAIN 1 (First Hour emissions) Sample Component Reagent Filter, Probe Weights or Dish # Final, mg...
  • Page 52 OMNI-Test Laboratories, Inc. Wood Heater Test Results - ASTM E3053 / ASTM E2515 Manufacturer: GHP Group Model: GHP Large Project No.: 0418WS018E Tracking No.: 2409 Run: 2 Test Date: 05/05/20 Burn Rate 1.18 kg/hr dry Average Tunnel Temperature 97 degrees Fahrenheit Average Gas Velocity in Dilution Tunnel - vs 20.62 feet/second...
  • Page 53 Wood Heater Efficiency Results - CSA B415.1 415.1 GHP Group Manufacturer: Technician Signature: GHP Large Model: 05/05/20 Date: Run: Control #: 0418WS018E Test Duration: Output Category: Test Results in Accordance with CSA B415.1-09 HHV Basis LHV Basis 75.8% 81.3% Overall Efficiency 96.1%...
  • Page 54 Adjunct to ASTM E XXXX Wood Heater Cordwood Test Method May 10, 2017 Version THIS DOCUMENT IS NOT AN ASTM STANDARD; IT IS UNDER CONSIDERATION WITHIN AN ASTM TECHNICAL COMMITTEE BUT HAS NOT RECEIVED ALL APPROVALS REQUIRED TO BECOME AN ASTM STANDARD. Cordwood Fuel Load Calculators 12 lb/ft Nominal Load Density IT SHALL NOT BE REPRODUCED OR CIRCULATED OR QUOTED, IN WHOLE OR IN PART, OUTSIDE OF ASTM...
  • Page 55 55 of 142...
  • Page 56 56 of 142...
  • Page 57 GHP Group, Inc. Model: Large Wood Stove Report Number:0418WS018E Run 3 High Burn 1-minute data Non-Sampling High Burn OMNI-Test Laboratories, Inc. 57 of 142...
  • Page 58 OMNI-Test Laboratories, Inc. Wood Heater Test Data - ASTM E3053 / ASTM E2515 Run: Manufacturer: GHP Group PM Control Modules: 371, 372 Model: Large Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: #DIV/0! ft/sec. Tracking No.: 2409 Total Sampling Time: Dilution Tunnel MW(wet): 28.78 lb/lb-mole...
  • Page 59 OMNI-Test Laboratories, Inc. Wood Heater Test Data - ASTM E3053 / ASTM E2515 Run: Manufacturer: GHP Group PM Control Modules: 371, 372 Model: Large Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: #DIV/0! ft/sec. Tracking No.: 2409 Total Sampling Time: Dilution Tunnel MW(wet): 28.78 lb/lb-mole...
  • Page 60 OMNI-Test Laboratories, Inc. Wood Heater Test Data - ASTM E3053 / ASTM E2515 Run: Manufacturer: GHP Group PM Control Modules: 371, 372 Model: Large Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: #DIV/0! ft/sec. Tracking No.: 2409 Total Sampling Time: Dilution Tunnel MW(wet): 28.78 lb/lb-mole...
  • Page 61 OMNI-Test Laboratories, Inc. Wood Heater Test Data - ASTM E3053 / ASTM E2515 Run: Manufacturer: GHP Group PM Control Modules: 371, 372 Model: Large Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: #DIV/0! ft/sec. Tracking No.: 2409 Total Sampling Time: Dilution Tunnel MW(wet): 28.78 lb/lb-mole...
  • Page 62 OMNI-Test Laboratories, Inc. Wood Heater Test Results - ASTM E3053 / ASTM E2515 Manufacturer: GHP Group Model: Large Project No.: 0418WS018E Tracking No.: 2409 Run: 3 Test Date: 05/06/20 Burn Rate 4.84 kg/hr dry Average Tunnel Temperature #DIV/0! degrees Fahrenheit...
  • Page 63 Adjunct to ASTM E XXXX Wood Heater Cordwood Test Method May 10, 2017 Version THIS DOCUMENT IS NOT AN ASTM STANDARD; IT IS UNDER CONSIDERATION WITHIN AN ASTM TECHNICAL COMMITTEE BUT HAS NOT RECEIVED ALL APPROVALS REQUIRED TO BECOME AN ASTM STANDARD. Cordwood Fuel Load Calculators 10 lb/ft Nominal Load Density IT SHALL NOT BE REPRODUCED OR CIRCULATED OR QUOTED, IN WHOLE OR IN PART, OUTSIDE OF ASTM...
  • Page 64 64 of 142...
  • Page 65 65 of 142...
  • Page 66 GHP Group, Inc. Model: Large Wood Stove Report Number:0418WS018E Run 4 Low Burn OMNI-Test Laboratories, Inc. 66 of 142...
  • Page 67 OMNI-Test Laboratories, Inc. Wood Heater Test Data - ASTM E3053 / ASTM E2515 Run: Manufacturer: GHP Group PM Control Modules: 371, 372 Model: GHP Large Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 19.95 ft/sec. Tracking No.: 2409 Total Sampling Time: Dilution Tunnel MW(wet): 28.78 lb/lb-mole...
  • Page 68 OMNI-Test Laboratories, Inc. Wood Heater Test Data - ASTM E3053 / ASTM E2515 Run: Manufacturer: GHP Group PM Control Modules: 371, 372 Model: GHP Large Dilution Tunnel MW(dry): 29.00 lb/lb-mole Avg. Tunnel Velocity: 19.95 ft/sec. Tracking No.: 2409 Total Sampling Time: Dilution Tunnel MW(wet): 28.78 lb/lb-mole...
  • Page 69 OMNI-Test Laboratories, Inc. Wood Heater Lab Data - ASTM E23053 / ASTM E2515 Manufacturer: GHP Equipment Numbers: Model: Large Tracking No.: 2409 Project No.: 0418WS018E Run #: 4 Date: 5/6/20 TRAIN 1 (First Hour emissions) Sample Component Reagent Filter, Probe Weights or Dish # Final, mg...
  • Page 70 OMNI-Test Laboratories, Inc. Wood Heater Test Results - ASTM E3053 / ASTM E2515 Manufacturer: GHP Group Model: GHP Large Project No.: 0418WS018E Tracking No.: 2409 Run: 4 Test Date: 05/06/20 Burn Rate 1.17 kg/hr dry Average Tunnel Temperature 92 degrees Fahrenheit Average Gas Velocity in Dilution Tunnel - vs 19.95 feet/second...
  • Page 71 Wood Heater Efficiency Results - CSA B415.1 415.1 GHP Group Manufacturer: Technician Signature: GHP Large Model: 05/06/20 Date: Run: Control #: 0418WS018E Test Duration: Output Category: Test Results in Accordance with CSA B415.1-09 HHV Basis LHV Basis 76.6% 82.1% Overall Efficiency 95.1%...
  • Page 72 Adjunct to ASTM E XXXX Wood Heater Cordwood Test Method May 10, 2017 Version THIS DOCUMENT IS NOT AN ASTM STANDARD; IT IS UNDER CONSIDERATION WITHIN AN ASTM TECHNICAL COMMITTEE BUT HAS NOT RECEIVED ALL APPROVALS REQUIRED TO BECOME AN ASTM STANDARD. Cordwood Fuel Load Calculators 12 lb/ft Nominal Load Density IT SHALL NOT BE REPRODUCED OR CIRCULATED OR QUOTED, IN WHOLE OR IN PART, OUTSIDE OF ASTM...
  • Page 73 73 of 142...
  • Page 74 74 of 142...
  • Page 75: Quality Assurance/Quality Control

    GHP Group, Inc. Model: Large Wood Stove Report Number:0418WS018E Section 4 Quality Assurance/Quality Control OMNI-Test Laboratories, Inc. 75 of 142...
  • Page 76 The manufacturing facilities and quality control system to produce the Large Wood Stove at GHP Group, Inc. were evaluated to determine if sufficient to maintain conformance with OMNI’s requirements for product certification. OMNI has concluded that the manufacturing facilities, processes, and quality control system are adequate to produce the appliance congruous with the standards and model codes to which it was evaluated.
  • Page 77: Sample Analysis

    GHP Group, Inc. Model: Large Wood Stove Report Number:0418WS018E Sample Analysis Analysis Worksheets Tared Filter, Probe, and O-Ring Data OMNI-Test Laboratories, Inc. 77 of 142...
  • Page 78 78 of 142...
  • Page 79 79 of 142...
  • Page 80 80 of 142...
  • Page 81 81 of 142...
  • Page 82 82 of 142...
  • Page 83 83 of 142...
  • Page 84 84 of 142...
  • Page 85 85 of 142...
  • Page 86 86 of 142...
  • Page 87 GHP Group, Inc. Model: Large Wood Stove Report Number:0418WS018E Calibrations ASTM E2515, ASTM E3053 ID # Lab Name/Purpose Log Name Attachment Type 10 lb Weight Weight Standard, 10 lb. Calibration Certificate Platform Scale United 1000 lb. Calibration Certificate 140TT029 283A...
  • Page 88 88 of 142...
  • Page 89 89 of 142...
  • Page 90 90 of 142...
  • Page 91 91 of 142...
  • Page 92 OMNI Test Laboratories, Inc. Thermal Metering System Calibration Y Factor Previous Calibration Comparision Acceptable Manufacturer: Apex Date 7/2/2019 Deviation (5%) Deviation Model: XC-60-EP y Factor 0.992 0.0496 0.004 Acceptable Serial Number: 0702003 Acceptance OMNI Tracking No.: OMNI-00371 Calibrated Orifice: FALSE Current Calibration Acceptable y Deviation 0.020...
  • Page 93 OMNI-Test Laboratories, Inc. DIFFERENTIAL PRESSURE GAUGE CALIBRATION DATA SHEET Instrument to be calibrated: Pressure Transducer______________ Maximum Range: 0-2” WC ID Number: OMNI-00371 Calibration Instrument: Digital Manometer ID Number: OMNI-00633 Date: 1/13/20 B. Davis This form is to be used only in conjunction with Standard Procedure C-SPC. Range of Digital Pressure Gauge...
  • Page 94 94 of 142...
  • Page 95 OMNI Test Laboratories, Inc. Thermal Metering System Calibration Y Factor Previous Calibration Comparision Acceptable Manufacturer: Apex Date 7/2/2019 Deviation (5%) Deviation Model: XC-60-EP y Factor 0.989 0.04945 0.004 Acceptable Serial Number: 0702004 Acceptance OMNI Tracking No.: OMNI-00372 Calibrated Orifice: FALSE Current Calibration Acceptable y Deviation 0.020...
  • Page 96 OMNI-Test Laboratories, Inc. DIFFERENTIAL PRESSURE GAUGE CALIBRATION DATA SHEET Instrument to be calibrated: Pressure Transducer______________ Maximum Range: 0-2” WC ID Number: OMNI-00372 Calibration Instrument: Digital Manometer ID Number: OMNI-00633 Date: 1/13/20 B. Davis This form is to be used only in conjunction with Standard Procedure C-SPC. Range of Digital Pressure Gauge...
  • Page 97 97 of 142...
  • Page 98 98 of 142...
  • Page 99 99 of 142...
  • Page 100 JJ Calibrations, Inc. Certificate of Calibration 7724 SE Aspen Summit Drive Portland, OR 97266-9217 Certificate Number: 716748 Phone 503.786.3005 FAX 503.786.2994 Omni-Test Laboratories O n S i t e 13327 NE Airport Way 190269 Portland, OR 97230 0723.01 Order Date: 01/20/2020 Calibration Authorized By:...
  • Page 101: Example Calculations

    GHP Group, Inc. Model: Large Wood Stove Report Number:0418WS018E Example Calculations OMNI-Test Laboratories, Inc. 101 of 142...
  • Page 102 OMNI-Test Laboratories, Inc. Equations and Sample Calculations – ASTM E3053 & E2515 Manufacturer: GHP Group Model: GHP Large Run: Category: Equations used to calculate the parameters listed below are described in this appendix. Sample calculations are provided for each equation. The raw data and printout results from a sample run are also provided for comparison to the sample calculations.
  • Page 103 OMNI-Test Laboratories, Inc. BR – dry burn rate, kg/hr ASTM E2780 equation (5) 60 M FTAdb Where, = Total length of test run, min Sample Calculation: = 9.36 = 475 60 x 9.36 1.18 kg/hr Control No. P-SSAR-0003 Medium Burn Run 2...
  • Page 104 OMNI-Test Laboratories, Inc. – Average gas velocity in the dilution tunnel, ft/sec ASTM E2515 equations (9) Where: strav , ASTM E2515 Equation (1) Adjustment factor for center of tunnel pitot tube placement, Fp = scent Dilution tunnel velocity calculated after the multi-point pitot traverse at the center, ft/sec scent Dilution tunnel velocity calculated after the multi-point pitot traverse, ft/sec strav...
  • Page 105 OMNI-Test Laboratories, Inc. – Average gas flow rate in dilution tunnel, dscf/hr ASTM E2515 equation (3) 3600 Where: 3600 Conversion from seconds to hours (ASTM method uses 60 to convert in minutes) Water vapor in gas stream, proportion by volume; assume 2% Cross sectional area of dilution tunnel, ft Standard absolute temperature, 528 °R Absolute average gas static pressure in dilution tunnel, = P...
  • Page 106 OMNI-Test Laboratories, Inc. – Volume of Gas Sampled Corrected to Dry Standard Conditions, dscf m(std) ASTM E2515 equation (6) Where: 17.64 °R/in. Hg Volume of gas sample measured at the dry gas meter, dcf Dry gas meter calibration factor, dimensionless Barometric pressure at the testing site, in.
  • Page 107 OMNI-Test Laboratories, Inc. – Total Particulate Matter Collected, mg ASTM E2515 Equation (12) Where: mass of particulate matter from probe, mg mass of particulate matter from filters, mg mass of particulate matter from filter seals, mg Sample Calculation: Using equation for Train 1 (first hour): Using equation for Train 1 (post-first hour): -1.4 Train 1 aggregate:...
  • Page 108 OMNI-Test Laboratories, Inc. - Concentration of particulate matter in tunnel gas, dry basis, corrected to standard conditions, g/dsc ASTM E2515 equation (13) Where: Constant, 0.001 g/mg Total mass of particulate matter collected in the sampling train, mg Volume of gas sampled corrected to dry standard conditions, dscf m(std) Sample calculation: For Train 1:...
  • Page 109 OMNI-Test Laboratories, Inc. – Total Particulate Emissions, g ASTM E2515 equation (15) Where: Concentration of particulate matter in tunnel gas, g/dscf Concentration particulate matter room air, g/dscf Average dilution tunnel gas flow rate, dscf/hr Total time of test run, minutes Sample calculation: For Train 1 = ( 0.000068 - 0...
  • Page 110 OMNI-Test Laboratories, Inc. PR - Proportional Rate Variation ASTM E2515 equation (16) Where: = Total sampling time, min = Length of recording interval, min = Volume of gas sample measured by the dry gas meter during the “ith” time interval, dcf = Volume of gas sample as measured by dry gas meter, dcf = Average gas velocity in the dilution tunnel during the "ith"...
  • Page 111 OMNI-Test Laboratories, Inc. – Particulate emissions for test run, g/hr ASTM E2780 equation (6) = 60 (E Where, = Total particulate emissions, grams = Total length of full integrated test run, min Sample Calculation: (Dual train average) = 6.63 g 475 min = 60 x ( 6.63 / 475 ) = 0.84...
  • Page 112 OMNI-Test Laboratories, Inc. – Particulate emission factor for test run, g/dry kg of fuel burned ASTM E2780 equation (7) FTAdb Sample Calculation: (Dual train average) = 6.63 g 9.36 kg 6.63 / 9.36 0.71 g/kg Control No. P-SSAR-0003 Medium Burn Run 2...
  • Page 113: Appendix A Manufacturer's Installation/Operation Instructions - Labels

    GHP Group, Inc. Model: Large Wood Stove Report Number:0418WS018E Appendix A Manufacturer’s Installation/Operation Instructions - Labels OMNI-Test Laboratories, Inc.
  • Page 114 2026 DATE OF MANUFACTURE: DATE DE FABRICATION: FABRIQUE AU ETATS UNIS PAR: GHP GROUP INC, 6440 W HOWARD ST., NILES IL 60714 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec HECHO EN LOS EE.UU. POR EL GRUPO GHP, INC, 6440 W HOWARD ST., NILES IL 60714...
  • Page 115 WARNING BEFORE LIGHTING YOUR FIRST FIRE, REMOVE PLASTIC FILM OFF TRIM AND CLEAN THE PLATED SURFACES WITH DENATURED ALCOHOL OR A GOOD QUALITY, NON-ABRASIVE LIQUID GLASS CLEANER. APPLY WITH A VERY SOFT, CLEAN CLOTH. DO NOT USE PAPER TOWELS TO CLEAN THE PLATED PARTS. FAILURE TO CLEAN ALL MARKS AND FINGERPRINTS FROM THE PLATED SURFACES WILL CAUSE PERMANENT DAMAGE.
  • Page 117 WARNING This product and the fuels used to operate this product (charcoal or wood), and the products of combustion of such fuels, can expose you to chemicals including carbon black, which is known to the State of California to cause cancer, and carbon monoxide, which is known to the State of California to cause birth defects or other reproductive harm.
  • Page 126 WOOD STOVE QUICK START GUIDE ITEMS NEEDED FOR START-UP FIRE: • 10 Pieces of Large Dry Kindling • 10 Pieces of Small Seasoned Split Wood • 1/2 lb of Small Dry Kindling START-UP FUEL OPEN AIR CONTROL CONFIGURATION Small Kindling SlideB affle RodH andle Start-Up Log...
  • Page 127 ITEMS NEEDED FOR FIRST FIRE: WOOD STOVE QUICK START GUIDE • 6 Pieces of Seasoned Split Wood 15-17 in. Long FUEL LOADING REDUCE AIR CONTROL LATCH STOVE DOOR CONFIGURATION Large Logs 15"-17" Long Embers CLOSED OPEN CLOSED Side-to-S Front-to-Back Position Damper Slide to Fully Once fire is fully burning, fully close and Position 3 Large Logs Front-to-Back on Top Open Setting for 7 Minutes, then...
  • Page 133 AREA OF MAINTENANCE TASK MONTHLY or After Every Cord of Wood cracks. YEARLY Vacuum the blower impellers. or After Every 4 Cords of Wood The chimney and chimney cap must be inspected for soot and creosote every two EVERY 2 months during the burn season or more frequency if chimney exceeds or is under MONTHS...
  • Page 134 Door Assembly 75-21-182 Push Nut 2 & 3 Glass (17.00” W x 9.75”) and Gasket 75-21-514 1/8” Glass Gasket 5/8” Door Gasket Spring Handle Air Control Sprint Handle Firebrick for Ash Drawer Glass Clip Ash Drawer Assembly Screw Leg Assembly Hinge Pin...
  • Page 135 2. The new GHP Group product must be installed and operated at all • This appliance has been subjected to prolonged periods of times in accordance with the installation and operation instructions dampness or condensation.
  • Page 136 6440 W. Howard St. Niles, IL 60714-3302 Tel: (877) 447-4768 www.ghpgroupinc.com...
  • Page 137: Appendix B Alt-125 E3053 Letter

    GHP Group, Inc. Model: Large Wood Stove Report Number:0418WS018E Appendix B Alt-125 E3053 Letter OMNI-Test Laboratories, Inc.
  • Page 138 227 of 229...
  • Page 139 228 of 229...
  • Page 140 229 of 229...
  • Page 141: Appendix C Firebox Volume

    GHP Group, Inc. Model: Large Wood Stove Report Number:0418WS018E Appendix C Firebox Volume OMNI-Test Laboratories, Inc.
  • Page 142 20.75 SECTION B-B SECTION A-A SCALE 1/8 SCALE 1/8 DRAWN DanDowning 5/13/2020 GHP GROUP INC 6440 W Howard St., Niles, IL 60714 MATERIAL TITLE Usable Firebox Volume TOLERANCES 2020 Large Wood Stove X.XXX = +/- 0.030" X.XX = +/- 0.060"...