Download Print this page

Sealey SA27.V2 Instructions page 2

13mm 700rpm reversible keyless chuck

Advertisement

3. specificaTiON
model no: ................................................................. sA27.V2
chuck size: ............................................................... Ø13mm
free speed: ................................................................ 700rpm
Air consumption: ............................................................ 4cfm
operating pressure: ...................................................... 90psi
inlet size: ...................................................................1/4"BSP
Weight: .......................................................................... 1.4kg
noise power/pressure: ....................................... 101/90dB(A)
Vibration/uncertainty: ......................................... 2.64/0.7m/s²
4. preparaTiON
4.1.
air supply
WarNiNG! Ensure the air supply is clean and does not exceed 90 psi while operating the drill. Too high an air pressure and
unclean air will cause excessive wear, and may be dangerous, causing damage and/or personal injury.
4.1.1.
Recommended hook-up procedure is shown in fig 1.
4.1.2.
ensure the drill air valve (or trigger) is not depressed before connecting to the air supply.
4.1.3.
You will require an air pressure between 70-90psi, and an air flow according to the specification above.
4.1.4.
drain the air tank daily. Water in the air line will damage the drill and invalidate your warranty.
4.1.5.
Clean air inlet filter weekly.
4.1.6.
line pressure should be increased to compensate for unusually long air hoses (over 8 metres).
4.1.7.
The minimum hose diameter should be 1/4" I.D. and fittings must have the same inside dimensions.
4.1.8.
Keep hose away from heat, oil and sharp edges. check hoses for wear, and make certain that all connections are secure.
4.2.
couplings
4.2.1.
Vibration may cause failure if a quick change coupling is connected directly to the air drill. to overcome this, connect a leader
hose - Sealey model number AH2R or AH2R/38 - to the drill. A quick change coupling may then be used to connect the leader hose
to the air line recoil hose. See figs.1 & 2.
fitting handle
4.3.
4.3.1.
slide the split brass ring over the chuck and onto the main black body of the drill. squeeze the split thread together and screw the
handle partially onto the ring. move the handle to your desired orientation and continue to screw the handle until it is locked in
position.
fig.1
fig.3
2
1
© Jack sealey limited
Original Language Version
fig.2
3
sA27.V2 | Issue:6 (L) 06/10/17

Advertisement